Dergiler / Research on Engineering Structures and Materials / 2021 / Cilt: 7 - Sayı: 4

High performance fiber reinforced concrete – for repair in spillways of concrete dams

Sayfa
505–522
Yayın Tarihi
2022-10-19
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Based on the study, the steel fibers with 1.5% dosage are found to be more effective in countering the abrasive and repetitive loading which can be more effective in the repairs of spillways and glacis of concrete dams.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Hydraulic structures like spillways, glacis, etc. undergoes abrasion-erosion due to impact & cavitation losses due to the flowing water action.
📊
Temel Bulgular & Veri:To overcome the deterioration of the concrete in such structures, addition of fibers to the concrete can be viable solution as it is known to increase the structural integrity of the concrete.
💡
Sonuç & Katkı:Based on the study, the steel fibers with 1.5% dosage are found to be more effective in countering the abrasive and repetitive loading which can be more effective in the repairs of spillways and glacis of concrete dams.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Hydraulic structures like spillways, glacis, etc. undergoes abrasion-erosion due to impact & cavitation losses due to the flowing water action. To overcome the deterioration of the concrete in such structures, addition of fibers to the concrete can be viable solution as it is known to increase the structural integrity of the concrete. A comparative study of various engineering characteristics using high strength concrete by incorporating steel fibers and micro polypropylene fibers has been carried out. Water/binder ratio of 0.23 has been kept constant for the study. Dosage for steel fibers is kept as 1, 1.25 and 1.5% by volume while for polypropylene fibers were kept as 1, 2 & 3 kg/m3. Engineering properties such compressive strength, flexural strength, toughness, energy absorption, splitting tensile strength, drying shrinkage, abrasion resistance, and water and air permeability of high-performance concrete with & without fibers in its fresh & hardened state are investigated in this paper. Based on the study, the steel fibers with 1.5% dosage are found to be more effective in countering the abrasive and repetitive loading which can be more effective in the repairs of spillways and glacis of concrete dams.

🔖

Bu Makaleye Atıf Yap

TRIVEDI, A., GUPTA, R., OJHA, P., SINGH, B., PATEL, V., S., A. K. N. (2022). High performance fiber reinforced concrete – for repair in spillways of concrete dams. Research on Engineering Structures and Materials, Cilt: 7 - Sayı: 4, 505–522. https://ajindex.com/articles/588849

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (15)

  1. Tony C, Liu James E, Mc Donald. Abrasion-erosion resistance of fibre reinforced concrete, Structural laboratory U S Army Engineer Waterways, 1981
  2. Terrence CH. Abrasion-erosion Evaluation of concrete Mixtures for stilling basin Repairs Kinzua Dam, Pennsylvania, Structural laboratory U S Army Engineer Waterways, 1983
  3. Papenfus N. Applying concrete technology to abrasion Resistance. Proceedings of 7th International Conference on Concrete Block Paving, Sun City, South Africa, October 2003
  4. Galvao JCA, Portella KF, Kormann ACM. Abrasive effects observed in concrete hydraulic surfaces of dams and application of repair materials, Federal Technological University of Parana, Brazil, March, 2012
  5. Wu CH, Yen T, Liu YW, Hsu TH. The Abrasion erosion resistance of Concrete Containing Blast Furnace Slag, Taiwan Power Company Report, 1994
  6. Kryzanowski A, Mikos M, Sustersistic J, Plannic I. Abrasion resistance of concrete in hydraulic structures, ACI Materials Journal, 2009; 106:4, 349-356.
  7. ACI Committee 546.R-2004. Concrete Repair Guide, 2004
  8. ACI Committee 210R-1993. Erosion of Concrete in Hydraulic Structures, 1993
  9. ACI Committee 544.4R-1988. Design consideration for steel Fibre Reinforced Concrete, [10] Lin WT,Cheng An. Abrasion resistance of cement-based composites, 2012.
  10. Hu XG, Momber AW, Yin YG. Hydro-abrasive erosion of steel-fibre reinforced hydraulic concrete, Institute of Tribology, Hefei University of Technology, Hefei, China, WOMA Apparatebau GmbH Duisburg, Germany, 2002.
  11. Stig O. Lack of practicable Standards & test methods restrict the development of Steel fibre Shotcrete, Steel fibre concrete US-Sweden joint seminar (NSF-STU) Stockholm, Sweden, June, 1985
  12. ACI Committee 544.1R-1996. State-of-the-Art Report on Fiber Reinforced Concrete
  13. Shah SP, Jeng YS. Fracture Resistance of Steel Fiber Reinforced Concrete, Steel fibre concrete US-Sweden joint seminar (NSF-STU) Stockholm, Sweden, June, 1985
  14. Gopalaratnam VS, Shah SP. Strength, Deformation & Fracture Toughness of fiber cement composite at different rates of flexural loading” Steel fibre concrete US-Sweden joint seminar (NSF-STU) Stockholm, Sweden, June, 1985
  15. Khayat KH, Kassimi F, Ghoddousi P. Mixture design and testing of fiber-reinforced Self Consolidating concrete. ACI materials journals, 2014, 111(2), 143-151. https://doi.org/10.1435