Dergiler / Joint diseases and related surgery / 2020 / Cilt: 31 - Sayı: 2

Role of computed tomography in determining the choice of treatment for delayed ceramic acetabular liner fracture: A case report

Sayfa
377–381
Yayın Tarihi
2022-10-19
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

By using CT imaging, we can detect which ceramic particles pose high morbidity risk for debridement.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Ceramic acetabular liner fracture is a rare complication and requires early revision surgery to avoid abrasive damaging of metal components by ceramic particles.
📊
Temel Bulgular & Veri:In this article, we report a 50-year-old male patient of delayed acetabular liner fracture in which we used a ceramic head that is more resistant to residue ceramic particles.
💡
Sonuç & Katkı:By using CT imaging, we can detect which ceramic particles pose high morbidity risk for debridement.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Ceramic acetabular liner fracture is a rare complication and requires early revision surgery to avoid abrasive damaging of metal components by ceramic particles. Chromium-cobalt femoral head can be used in revision surgery if only fractured ceramic particles are completely removed because the abrasive effect of ceramic debris is more pronounced on metal head compared to ceramic head. In this article, we report a 50-year-old male patient of delayed acetabular liner fracture in which we used a ceramic head that is more resistant to residue ceramic particles. We assessed the patient by using computed tomography (CT) to locate the ceramic particles. By using CT imaging, we can detect which ceramic particles pose high morbidity risk for debridement.

🔖

Bu Makaleye Atıf Yap

DIRVAR, F. (2022). Role of computed tomography in determining the choice of treatment for delayed ceramic acetabular liner fracture: A case report. Joint diseases and related surgery, Cilt: 31 - Sayı: 2, 377–381. https://ajindex.com/articles/559280

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. D’Antonio JA, Sutton K. Ceramic materials as bearing surfaces for total hip arthroplasty. J Am Acad Orthop Surg 20 09;17:63 - 8
  2. Hamilton WG, McAuley JP, Dennis DA, Murphy JA, Blumenfeld TJ, Politi J. THA with Delta ceramic on ceramic: results of a multicenter investigational device exemption trial. Clin Orthop Relat Res 2010;468:358-66
  3. Sharma V, Ranawat AS, Rasquinha VJ, Weiskopf J, Howard H, Ranawat CS. Revision total hip arthroplasty for ceramic head fracture: a long-term follow-up. J Arthroplasty 2010;25:342-7
  4. Matziolis G, Perka C, Disch A. Massive metallosis after revision of a fractured ceramic head onto a metal head. Arch Orthop Trauma Surg 2003;123:48-50
  5. Allain J, Roudot-Thoraval F, Delecrin J, Anract P, Migaud H, Goutallier D. Revision total hip arthroplasty performed after fracture of a ceramic femoral head. A multicenter survivorship study. J Bone Joint Surg [Am] 2003;85:825-30
  6. Traina F, De Fine M, Di Martino A, Faldini C. Fracture of ceramic bearing surfaces following total hip replacement: a systematic review. Biomed Res Int 2013;2013:157247
  7. Lee SJ, Kwak HS, Yoo JJ, Kim HJ. Bearing Change to Metal-On-Polyethylene for Ceramic Bearing Fracture in Total Hip Arthroplasty; Does It Work? J Arthroplasty 2016;31:204-8
  8. Traina F, Tassinari E, De Fine M, Bordini B, Toni A. Revision of ceramic hip replacements for fracture of a ceramic component: AAOS exhibit selection. J Bone Joint Surg [Am] 2 0 11; 9 3: e 14 7
  9. Atik OŞ. Which articles do we prefer to publish? Eklem Hastalik Cerrahisi 2018;29:1
  10. Winston BA, Kagan RP, Huff TW. Delayed diagnosis of catastrophic ceramic liner failure with resultant pelvic discontinuity and massive metallosis. Arthroplast Today 2016;3:77-82
  11. Trebše R, Mihelič A, Levašič V, Cör A, Milošev I. Results of revision of total hip arthroplasty for alumina ceramic-on-ceramic bearing fracture. Hip Int 2016;26:237-43
  12. Trivellin G, Sandri A, Bizzotto N, Marino MA, Mezzari S, Sambugaro E, et al. Ceramic liner fatigue fracture: 3-D CT findings in a late recurrent THA dislocation. Orthopedics 2013;36:e101-4
  13. Takasago T, Goto T, Wada K, Hamada D, Iwame T, Matsuura T, et al. Metallosis after Exchange of the Femoral Head and Liner following Ceramic Acetabular Liner Dissociation in Total Hip Arthroplasty with a Modular Layered Acetabular Component. Case Rep Orthop 2016;2016:5301451
  14. Endo Y, Renner L, Schmidt-Braekling T, Mintz DN, Boettner F. Imaging of ceramic liner fractures in total hip