Dergiler / International Journal of Automotive Engineering and Technologies / 2021 / Cilt: 10 - Sayı: 1

Experimental performance evaluation of an R1234yf automobile air conditioning system employing an internal heat exchanger

Sayfa
50–59
Yayın Tarihi
2022-10-18
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Consequently, the performance of R1234yf AACsystems can be improved with the use of HEX, and thus, the AAC systems usingR1234yf can be more competitive with those using R134a

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:A bench-top automobile air conditioning (AAC) system using a thermostaticexpansion valve was developed.
📊
Temel Bulgular & Veri:The system was equipped with a coaxial internalheat exchanger (HEX) and charged with R1234yf, a new refrigerant used as analternative to R134a.
💡
Sonuç & Katkı:Consequently, the performance of R1234yf AACsystems can be improved with the use of HEX, and thus, the AAC systems usingR1234yf can be more competitive with those using R134a
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

A bench-top automobile air conditioning (AAC) system using a thermostaticexpansion valve was developed. The system was equipped with a coaxial internalheat exchanger (HEX) and charged with R1234yf, a new refrigerant used as analternative to R134a. The system was tested at the compressor speeds rangingbetween 1000 rpm and 2600 rpm with increments of 400 rpm. For eachcompressor speed, the air temperatures at the evaporator and condenser inlets wereconcurrently changed between 30 °C and 40 °C with increments of 5 °C. Thesystem was operated for the cases of employing and not employing the HEX, andtotally 30 test runs were performed. Then, the first law of thermodynamics wasapplied to the system components to evaluate various steady state performanceparameters. The considered parameters were the refrigerant mass flow rate,evaporating temperature, cooling capacity, compressor power, coefficient ofperformance (COP), condenser heat dissipation rate and discharge temperature ofthe compressor. It was determined that the experimental system employing theHEX yielded on average 0.8 °C lower evaporating temperature, 2.2% highercooling capacity, 2.0% lower compressor power and 3.0% higher COP valuesrelative to the system not employing the HEX. These findings reveal that the useof HEX causes a better system performance in terms of the cooling capacity,compressor power and COP. Consequently, the performance of R1234yf AACsystems can be improved with the use of HEX, and thus, the AAC systems usingR1234yf can be more competitive with those using R134a

🔖

Bu Makaleye Atıf Yap

HOŞÖZ, M., GÜNGÖR, U. (2022). Experimental performance evaluation of an R1234yf automobile air conditioning system employing an internal heat exchanger. International Journal of Automotive Engineering and Technologies, Cilt: 10 - Sayı: 1, 50–59. https://ajindex.com/articles/540278

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. UNEP, “Montreal Protocol on substances that deplete the ozone layer, final act”, United Nations Environment Programme, 1987
  2. Lee, Y. and Jung, D., “A brief performance comparison of R1234yf and R134a in a bench tester for automobile applications”, Applied Thermal Engineering, 35, 240-242, 2012
  3. EU, “Regulation (EU) No 517/2014 of the European Parliament and of the Council of 16 April 2014 on fluorinated greenhouse gases and repealing Regulation (EC) No 842/2006”, Official Journal of European Union, L 150/195, 2014
  4. Zilio, C., Brown, S.J., Schiochet, G. and Cavallini, A., “The refrigerant R1234yf in air conditioning systems”, Energy, 36(10), 6110– 6120, 2011
  5. Zhao, Y., Qi, Z., Chen, J., Xu, B. and He, B., “Experimental analysis of the low-GWP refrigerant R1234yf as a drop-in replacement for R134a in a typical mobile air conditioning system”, Journal of Mechanical Engineering Science, 226, 2713–2725, 2012
  6. Mota-Babiloni, A., Navarro-Esbri, J., Barragan-Cervera, A., Moles, F. and Peris, B., “Drop-in energy performance evaluation of R1234yf and R1234ze(e) in a vapor compression system as R134a replacements”, Applied Thermal Engineering, 71, 259–265, 2014
  7. Meng, Z., Zhang, H., Lei, M., Qin, Y. and Qiu, J., “Performance of low GWP R1234yf/R134a mixture as a replacement for R134a in automotive air conditioning systems”, International Journal of Heat and Mass Transfer, 116, 362–370, 2018
  8. Li, Z., Liang, K. and Jiang, H., “Experimental study of R1234yf as a drop-in replacement for R134a in an oil-free refrigeration system”, Applied Thermal Engineering, 153, 646–654, 2019
  9. Aral, M.C., Suhermanto, M. and Hosoz, M., “Performance evaluation of an automotive air conditioning and heat pump system using R1234yf and R134a”, Science and Technology for the Built Environment, 27, 44–60, 2021
  10. Cho, H., Lee, H. and Park, C., “Performance characteristics of an automobile air conditioning system with internal heat exchanger using refrigerant R1234yf”, Applied Thermal Engineering, 61(2), 563–569, 2013
  11. Navarro-Esbri, J., Moles, F. and Barragan-Cervera, A., “Experimental analysis of the internal heat exchanger influence on a vapour compression system performance working with R1234yf as a drop-in replacement for R134a, Applied Thermal Engineering”, 59(1-2), 153–161, 2013
  12. Direk, M., Kelesoglu, A. and Akin, A., “Drop-in performance analysis and effect of IHX for an automotive air conditioning system with R1234yf as a replacement of R134a”, Journ