Dergiler / International Journal of Automotive Engineering and Technologies / 2021 / Cilt: 10 - Sayı: 1

Experimental performance evaluation of an R1234yf automobile air conditioning system employing an internal heat exchanger

Sayfa
50–59
Yayın Tarihi
2021-03-31
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Consequently, the performance of R1234yf AAC systems can be improved with the use of HEX, and thus, the AAC systems using R1234yf can be more competitive with those using R134a.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:A bench-top automobile air conditioning (AAC) system using a thermostatic expansion valve was developed.
📊
Temel Bulgular & Veri:The system was equipped with a coaxial internal heat exchanger (HEX) and charged with R1234yf, a new refrigerant used as an alternative to R134a.
💡
Sonuç & Katkı:Consequently, the performance of R1234yf AAC systems can be improved with the use of HEX, and thus, the AAC systems using R1234yf can be more competitive with those using R134a.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Automobile · Air conditioning · R1234yf

Abstract

A bench-top automobile air conditioning (AAC) system using a thermostatic expansion valve was developed. The system was equipped with a coaxial internal heat exchanger (HEX) and charged with R1234yf, a new refrigerant used as an alternative to R134a. The system was tested at the compressor speeds ranging between 1000 rpm and 2600 rpm with increments of 400 rpm. For each compressor speed, the air temperatures at the evaporator and condenser inlets were concurrently changed between 30 °C and 40 °C with increments of 5 °C. The system was operated for the cases of employing and not employing the HEX, and totally 30 test runs were performed. Then, the first law of thermodynamics was applied to the system components to evaluate various steady state performance parameters. The considered parameters were the refrigerant mass flow rate, evaporating temperature, cooling capacity, compressor power, coefficient of performance (COP), condenser heat dissipation rate and discharge temperature of the compressor. It was determined that the experimental system employing the HEX yielded on average 0.8 °C lower evaporating temperature, 2.2% higher cooling capacity, 2.0% lower compressor power and 3.0% higher COP values relative to the system not employing the HEX. These findings reveal that the use of HEX causes a better system performance in terms of the cooling capacity, compressor power and COP. Consequently, the performance of R1234yf AAC systems can be improved with the use of HEX, and thus, the AAC systems using R1234yf can be more competitive with those using R134a.

🔖

Bu Makaleye Atıf Yap

GÜNGÖR, U., HOŞÖZ, M. (2021). Experimental performance evaluation of an R1234yf automobile air conditioning system employing an internal heat exchanger. International Journal of Automotive Engineering and Technologies, Cilt: 10 - Sayı: 1, 50–59. https://ajindex.com/articles/258241

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. UNEP, “Montreal Protocol on substances that deplete the ozone layer, final act”, United Nations Environment Programme, 1987.
  2. Lee, Y. and Jung, D., “A brief performance comparison of R1234yf and R134a in a bench tester for automobile applications”, Applied Thermal Engineering, 35, 240-242, 2012. EU, “Regulation (EU) No 517/2014 of the European Parliament and of the Council of 16 April 2014 on fluorinated greenhouse gases and repealing Regulation (EC) No 842/2006”,
  3. Official Journal of European Union, L 150/195, 2014.
  4. Zilio, C., Brown, S.J., Schiochet, G. and Cavallini, A., “The refrigerant R1234yf in air conditioning systems”, Energy, 36(10), 6110–6120, 2011.
  5. Zhao, Y., Qi, Z., Chen, J., Xu, B. and He, B., “Experimental analysis of the low-GWP refrigerant R1234yf as a drop-in replacement for R134a in a typical mobile air conditioning system”, Journal of Mechanical Engineering Science, 226, 2713–2725, 2012.
  6. Mota-Babiloni, A., Navarro-Esbri, J., Barragan-Cervera, A., Moles, F. and Peris, B., “Drop-in energy performance evaluation of R1234yf and R1234ze(e) in a vapor compression system as R134a replacements”, Applied Thermal Engineering, 71, 259–265, 2014.
  7. Meng, Z., Zhang, H., Lei, M., Qin, Y. and Qiu, J., “Performance of low GWP R1234yf/R134a mixture as a replacement for R134a in automotive air conditioning systems”, International Journal of Heat and Mass Transfer, 116, 362–370, 2018.
  8. Li, Z., Liang, K. and Jiang, H., “Experimental study of R1234yf as a drop-in replacement for R134a in an oil-free refrigeration system”, Applied Thermal Engineering, 153, 646–654, 2019.
  9. Aral, M.C., Suhermanto, M. and Hosoz, M., “Performance evaluation of an automotive air conditioning and heat pump system using R1234yf and R134a”, Science and Technology for the Built Environment, 27, 44–60, 2021.
  10. Cho, H., Lee, H. and Park, C., “Performance characteristics of an automobile air conditioning system with internal heat exchanger using refrigerant R1234yf”, Applied Thermal Engineering, 61(2), 563–569, 2013.
  11. Navarro-Esbri, J., Moles, F. and Barragan-Cervera, A., “Experimental analysis of the internal heat exchanger influence on a vapour compression system performance working with R1234yf as a drop-in replacement for R134a, Applied Thermal Engineering”, 59(1-2), 153–161, 2013.
  12. Direk, M., Kelesoglu, A. and Akin, A., “Drop-in performance analysis and effect of IHX for an automotive air conditioning system with R1234yf as a replacement of R134a”, Journal of Mechanical Engineering, 63(5), 314