Dergiler / International Dental Research / 2018 / Cilt: 8 - Sayı: 3

An evaluation using micro-CT data of the stress formed in the crown and periodontal tissues from the use of PEEK post and PEEK crown: A 3D finite element analysis study

Sayfa
144–150
Yayın Tarihi
2022-10-19
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The use of PEEK crown reduced thestresses occurring on the crown and increased the stresses occurring on thePDL and cortical bone.Conclusions: With further in vitro and clinical studies of PEEK material,it can be considered that within a short time PEEK post and PEEK crowncould be in routine use in dentistry.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Aim: Metal-supported ceramics as crown material and glass fiber posts asdental post materials are in frequent current use.
📊
Temel Bulgular & Veri:The aim of this study was to usefinite element analysis (FEA) to compare the stresses formed by forcesapplied after the use of PEEK material as dental post and crown materialas an alternative to glass fiber posts and metal-supported ceramic crowns.Methodology: The stress analysis method used in this study was FEA.First, micro-computed tomography (micro-CT) images were obtained of amaxillary central incisor tooth and the data of the post materials scannedwith a 3-dimensional (3D) laser scanner were uploaded to a computerprogram. 3D models were obtained with designs made in the computerprogram of all the materials.
💡
Sonuç & Katkı:The use of PEEK crown reduced thestresses occurring on the crown and increased the stresses occurring on thePDL and cortical bone.Conclusions: With further in vitro and clinical studies of PEEK material,it can be considered that within a short time PEEK post and PEEK crowncould be in routine use in dentistry.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Aim: Metal-supported ceramics as crown material and glass fiber posts asdental post materials are in frequent current use. In recent years, it hasbeen claimed that stress-based biomechanical problems in dentistry canbe resolved with the benefit of the low elasticity modulus ofpolyetheretherketone (PEEK) material. The aim of this study was to usefinite element analysis (FEA) to compare the stresses formed by forcesapplied after the use of PEEK material as dental post and crown materialas an alternative to glass fiber posts and metal-supported ceramic crowns.Methodology: The stress analysis method used in this study was FEA.First, micro-computed tomography (micro-CT) images were obtained of amaxillary central incisor tooth and the data of the post materials scannedwith a 3-dimensional (3D) laser scanner were uploaded to a computerprogram. 3D models were obtained with designs made in the computerprogram of all the materials. The modelling of a maxillary central toothwas completed using 2 different post materials (glass fiber and PEEK) and2 different crown materials (metal ceramic and PEEK) and 4 groups wereformed for analysis. By applying force of 100 N at 135ofrom the absolutecentral point of the palatinal surface of the tooth, the stress values anddistribution occurring in the 3D periodontal models were compared.Results: The use of PEEK post reduced the stresses occurring on theperiodontal ligament (PDL) and the cortical bone, and caused no significantchange in the stresses on the crown. The use of PEEK crown reduced thestresses occurring on the crown and increased the stresses occurring on thePDL and cortical bone.Conclusions: With further in vitro and clinical studies of PEEK material,it can be considered that within a short time PEEK post and PEEK crowncould be in routine use in dentistry.

🔖

Bu Makaleye Atıf Yap

TEKİN, S., ADIGÜZEL, Ö., CANGÜL, S. (2022). An evaluation using micro-CT data of the stress formed in the crown and periodontal tissues from the use of PEEK post and PEEK crown: A 3D finite element analysis study. International Dental Research, Cilt: 8 - Sayı: 3, 144–150. https://ajindex.com/articles/539556

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Schwartz RS, Robbins JW. Post placement and restoration of endodontically treated teeth: a literature review. J Endod 2004; 30: 289-301. (Crossref
  2. Coelho C, Biffi J, Silva G, Abrahao A, Campos R, Soares C. Finite element analysis of weakened roots restored with composite resin and posts. Dent Mater J 2009; 28: 671-678. (Crossref
  3. Yıkılgan I, Bala O. Conservative restorations of endodontically treated teeth. Acta Odontol Turcica 2013;30(1):44-8
  4. Lassilla LVJ, Tanner J, Le Bell AM, Narva K, Vallittu PK. Flexural properties of fiber reinforce root canal posts. Dent Mater 2004; 20:29e36
  5. Saupe WA, Gluskin AH, Radeke RA Jr. A comparative study of fractureresistance between morphologic dowel and cores and a resin-reinforced dowel system in the intraradicular restoration of structurally compromise droots. Quintessence Int 1996; 27:483-91
  6. Ona M, Wakabayashi N, Yamazaki T, Takaichi A, Igarashi Y.The influence of elastic modulus mismatch between tooth and post and core restorations on root fracture. Int Endod J 2013;46: 47- 52. (Crossref
  7. R. May, Polyetheretherketones, in: H.F. Mark, N.M. Bikales, C.G. Overberger, G. Menges, J.I. Kroschiwitz (Eds.), Encyclopedia of Polymer Science and Engineering, John Wiley and Sons, New York, 1988;313-320
  8. Najeeb S, Zafar MS, Khurshid Z, Siddiqui F. Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics. J Prosthodont Res 2016;60:12-9. (Crossref
  9. Wimmer T, Jahn D, Sener B, Roos M, Schmidlin PR. Polyetheretherketone A suitable material for fixed dental prostheses? J Biomed Mater Res B Appl Biomater 2013;101:1209-16. (Crossref
  10. José María Parmigiani-Izquierdo JM, Cabaña-Muñoz ME, Merino JJ and Sánchez-Pérez A. Zirconia implants and peek restorations for the replacement of upper molars. 2017;3:5 (Crossref
  11. Zoidis P, & Papathanasiou I. Modified PEEK resin-bonded fixed dental prosthesis as an interim restoration after implant placement. The Journal of prosthetic dentistry. 2016;116(5):637-41. (Crossref
  12. Cortada M, Giner LL, Costa S, Gil FJ, Rodriguez D, Planell JA. Galvanic corrosion behavior of titanium implants coupled to dental alloys. J. Mater. Sci. Mater. Med. 2002;5:287–93
  13. Bechir, E. S., Bechir, A., Gioga, C., Manu, R., Burcea, A., & Dascalu, I. T. The Advantages of BioHPP Polymer as Superstructure Material in Oral Implantology. Materiale Plastice, 2016; 53(3):394-8
  14. Genovese K, Lamberti L, Pappalettere C. Finite element analysis of a new customized co