BFRBCs showed clinically acceptable bottom/top hardness ratios.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Aim: The aim of this study was to compare the Vickers hardness numbers (VHNs) of two bulk-fill resin-based composites (BFRBC) and a conventional hybrid resin-based composite (RBC) through the layers of a 5mm thickness model with two different light-curing time intervals.
📊
Temel Bulgular & Veri:Semi-cylindrical specimens 4 mm in radius and 5 mm in height were prepared using a twopiece stainless-steel mold (n=10).
💡
Sonuç & Katkı:BFRBCs showed clinically acceptable bottom/top hardness ratios.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Aim: The aim of this study was to compare the Vickers hardness numbers (VHNs) of two bulk-fill resin-based composites (BFRBC) and a conventional hybrid resin-based composite (RBC) through the layers of a 5mm thickness model with two different light-curing time intervals. Methodology: In the present study, a sonic-activated and dual-cure BFRBC, and a conventional hybrid RBC were used. Semi-cylindrical specimens 4 mm in radius and 5 mm in height were prepared using a twopiece stainless-steel mold (n=10). The BFRBCs allowed a single 5mm increment to be introduced into the molds, whereas hybrid RBC was incremented (2+2+1 mm). Two different time intervals were applied for the light-curing (irradiance of 1200 mW/cm2) of each material (hybridsonic-activated bulk-fill, 20 s and 40 s; dual-cure bulk-fill, 7 s and 15 s). VHN measurements were carried out from top to bottom at every 1 mm of the specimen thickness. Data were analyzed using three-way and two-way ANOVA for the VHN and bottom/top ratios and Bonferroni correction for multiple comparisons (p=0.05). Results: For each layer and time interval groups, there was a significant difference between the materials. The highest VHN was found within hybrid groups, whereas dual-cure bulk-fill groups showed the lowest results. Sonic-activated bulk-fill had the lowest bottom/top ratios, which were significantly different from those of the other materials. There was no significant difference between the different time intervals for bottom/top ratios within each material. Conclusion: Increased irradiation intervals positively affected the VHN of hybrid and dual-cure bulk-fill. BFRBCs showed clinically acceptable bottom/top hardness ratios.

🔖

Bu Makaleye Atıf Yap

DEMİR, O., BAL, F. A., AĞACCIOĞLU, M. (2022). A comparative study of the 5 mm-layer Vickers hardness model with bulk-fill resin-based composites. International Dental Research, Cilt: 11 - Sayı: 3, 172–179. https://ajindex.com/articles/539456

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Fugolin APP, Pfeifer CS. New Resins for Dental Composites. J Dent Res 2017; 96:1085-91. (Crossref
  2. Lima RBW, Troconis CCM, Moreno MBP, Murillo-Gómez F, De Goes MF. Depth of cure of bulk-fill resin composites: A systematic review. J Esthet Restor Dent 2018; 30: 492–501. (Crossref
  3. Chesterman J, Jowett A, Gallacher A, Nixon P. Bulk-fill resinbased composite restorative materials: a review. Br Dent J 2017; 222:337-44. (Crossref
  4. Agaccioglu M, Cevval Ozkocak BB, Aytac Bal F. A General Look Through Bulk-Fill Resin-Based Composites. In: Uzel I, editor. Current dental studies. 1st ed. Ankara: Akademisyen Kitabevi AŞ.; 2020. p. 93–110
  5. Czasch P, Ilie N. In vitro comparison of mechanical properties and degree of cure of bulk-fill composites. Clin Oral Investig 2013;17: 227-35. (Crossref
  6. Ozel E, Tuna EB, Firatli E. The effects of cavity-filling techniques on microleakage in class II resin restorations prepared with Er:YAG laser and diamond bur: A scanning electron microscopy study. Scanning 2016; 38:389-95. (Crossref
  7. Oglakci B, Kazak M, Donmez N, Dalkilic EE, Koymen SS. The use of a liner under different bulk-fill resin composites: 3D GAP formation analysis by x-ray microcomputed tomography. J Appl Oral Sci 2020; 28: e20190042. (Crossref
  8. Ronald L. Sakaguchi JMP. Craig’s Restorative Dental Materials. 13th ed. Elsevier; 2012. 33–81
  9. Besegato JF, Jussiani EI, Andrello AC, Fernandes RV, Salomão FM, Vicentin BLS, et al. Effect of light-curing protocols on the mechanical behavior of bulk-fill resin composites. J Mech Behav Biomed Mater 2019; 90:381–7. (Crossref
  10. Leprince JG, Leveque P, Nysten B, Gallez B, Devaux J, Leloup G. New insight into the “depth of cure” of dimethacrylatebased dental composites. Dent Mater 2012; 28:512–20. (Crossref
  11. Kim E-H, Jung K-H, Son S-A, Hur B, Kwon Y-H, Park J-K. Effect of resin thickness on the microhardness and optical properties of bulk-fill resin composites. Restor Dent Endod 2015; 40:512- 20. (Crossref
  12. Aggarwal N, Jain A, Gupta H, Abrol A, Singh C, Rapgay T. The comparative evaluation of depth of cure of bulk-fill composites – An in vitro study. J Conserv Dent 2019; 22: 371. (Crossref
  13. Monterubbianesi R, Orsini G, Tosi G, Conti C, Librando V, Procaccini M, et al. Spectroscopic and mechanical properties of a new generation of bulk-fill composites. Front Physiol 2016; 7. (Crossref
  14. Finan L, Palin WM, Moskwa N, McGinley EL, Fleming GJP. The influence of irradiation potential on the degree