Dergiler / Hittite Journal of Science and Engineering / 2016 / Cilt: 3 - Sayı: 1

Non-Enzymatic Phenol Determination in River Water Over Modified Electrode with Poly(3-methylthiophene)

Sayfa
35–40
Yayın Tarihi
2022-10-18
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Proposed method was found as simple, rapid and economic for phenol determination.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:T his paper describes non-enzymatic phenol determination using poly(3methylthiophene) coated Pt electrode.
📊
Temel Bulgular & Veri:Modified electrode was prepared on Pt disc surface in dichloromethane medium containing 500 mM 3-methylthiophene (3MT) and 100 mM tetrabuthylammonium perchlorate (TBAP).
💡
Sonuç & Katkı:Proposed method was found as simple, rapid and economic for phenol determination.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

T his paper describes non-enzymatic phenol determination using poly(3methylthiophene) coated Pt electrode. Modified electrode was prepared on Pt disc surface in dichloromethane medium containing 500 mM 3-methylthiophene (3MT) and 100 mM tetrabuthylammonium perchlorate (TBAP). This electrode was used for amperometric determination of phenol in NaHSO4 / Na2SO4 (SBS) solution at pH 2.0. For this purpose, 0.70, 0.80 and 0.90 V potentials were applied and results were compared. Limit of detection and linear range were found as 4.22x10-5 and 1.41x104 - 4.00 mM (with R2=0.9932) at 0.90 V working potential, respectively. Repeatability of method was tested by using at least three modified electrode for 0.5, 1.0 and 2.0 mM phenol concentrations and relative standard deviation (RSD were found as 2.49%, 1.92% and 2.75%, respectively. To test the accuracy of method and matrix effect, phenol determination was carried out for 1.0 and 2.0 mM phenol concentrations in artificially contaminated river water samples at optimum condition and recovery values were found as 96.44% and 99.60%, respectively. Proposed method was found as simple, rapid and economic for phenol determination.

🔖

Bu Makaleye Atıf Yap

ÜLKER, E., BÜK, U., KAVANOZ, M. (2022). Non-Enzymatic Phenol Determination in River Water Over Modified Electrode with Poly(3-methylthiophene). Hittite Journal of Science and Engineering, Cilt: 3 - Sayı: 1, 35–40. https://ajindex.com/articles/538093

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (11)

  1. Yang X, Zou R, Huo F, Cai D, Xiao D. Preparation and characterization of Ti/SnO2-Sb2O3-Nb2O5/PbO2 thin film as electrode material for the degradation of phenol. Journal of Hazardous materials 164 (2009) 367-373.
  2. Ma H, Zhang X, Ma Q, Wang B. Electrochemical catalytic treatment of phenol wastewater. Journal of Hazardous materials 165 (2009) 475-480. Wallace J. In Kirk-Othmer encyclopedia of chemical toxicology; Kroschwitz JI, Howe-Grant M, Eds.; John Wiley & Sons: New York, forth edition, pp. 592-602, 1996.
  3. Rothman N, Bechtold WE, Yin S-N, Dosemeci M, Li G-L, Wang Y-Z, Griffith WC, Smith MT, Hayes RB. Urinary excretion of phenol, catechol, hydroquinone, and muconic acid by workers occupationally exposed to benzene. Occupational and Environmental Medicine 55 (1998) 705-711. ?vitel J. Development of Tyrosinase-Based Biosensor and Its Application for Monitoring of Bioremediation of Phenol and Phenolic Compounds. Environmental Science & Technology 32 (1998) 828-832.
  4. Vrsaljko D, Haramija V, Had?i-Skerlev A. Determination of phenol, m-cresol and o-cresol in transformer oil by HPLC method. Electric Power Systems Research 93 (2012) 24-31.
  5. Es-haghi A, Baghernejad M, Bagheri H. In situ solidphase microextraction and post on-fiber derivatization combined with gas chromatography-mass spectrometry for determination of phenol in occupational air. Analytica Chimica Acta 742 (2012) 17-21.
  6. Zhao W, Liu W, Ge J, Wu J, Zhang W, Meng X, Wang P. A novel fluorogenic hybrid material for selective sensing of thiophenols. Journal of Materials Chemistry 21 (2011) 13561-13568.
  7. He K, Wang X, Meng X, Zheng H, Suye S-i. Amperometric determination of hydroquinone and catechol on gold electrode modified by direct electrodeposition of poly(3,4- ethylenedioxythiophene). Sensors and Actuators B: Chemical 193 (2014) 212-219.
  8. Kavanoz M, Pekmez NÖ. Poly(vinylferrocenium) perchlorate- polyaniline composite film-coated electrode for amperometric determination of hydroquinone. Journal of Solid State Electrochemistry 16 (2012) 1175-1186.
  9. Tehrani MAR, Ghadimi H, Ab Ghani S. Electrochemical studies of two diphenols isomers at graphene nanosheet-poly(4- vinyl pyridine) composite modified electrode. Sensors and Actuators B: Chemical 177 (2013) 612-619.
  10. Quynh BTP, Byun JY, Kim SH. Non-enzymatic amperometric detection of phenol and catechol using nanoporous gold. Sensors and Actuators B: Chemical 221 (2015) 191-200.
  11. Nurul Karim M, Lee HJ. Amperometric phenol biosensor based on covalent immobilization of ty