Dergiler / Hittite Journal of Science and Engineering / 2018 / Cilt: 5 - Sayı: 2

Design and Implementation of an Underwater Telemetric Glucose Monitoring System for Scuba Divers

Sayfa
141–146
Yayın Tarihi
2022-10-18
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

It offers as well an emergency system to monitor the non-diabetic divers during extreme exposures such as saturation diving.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Despite the abundance of telemetric applications for ecology, behaviour and physiology of marine life, few efforts were reported about the use of acoustic telemetry for SCUBA divers.
📊
Temel Bulgular & Veri:This board works as a relay to transmit the blood glucose value to an acoustic modem SAM-1 Desert Star Systems LLC, Monterey Bay, CA, USA via RS232 serial communication.
💡
Sonuç & Katkı:It offers as well an emergency system to monitor the non-diabetic divers during extreme exposures such as saturation diving.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Diabetes · Underwater · Diving

Abstract

Despite the abundance of telemetric applications for ecology, behaviour and physiology of marine life, few efforts were reported about the use of acoustic telemetry for SCUBA divers. Such systems are required to follow the medical conditions of divers with chronic health problems such as diabetics. This study communicates the details of a study to design, manufacture and test a prototype system that measures the blood glucose while diving and transmit the results in real time to the surface. A subcutaneous glucose sensor placed on the diver transmits wirelessly the glycaemia data to a microcontroller based RF receiver board placed in a custom built waterproof casing. This board works as a relay to transmit the blood glucose value to an acoustic modem SAM-1 Desert Star Systems LLC, Monterey Bay, CA, USA via RS232 serial communication. The modem transmits the data to the other modem, which is placed underwater at 1 m depth with a maximum baud rate of 100 bit/sec with ultrasound communication. Finally, the data reaches a portable computer from RS232 serial interface of the acoustic modem. The data is displayed and logged on the computer based at the surface. The whole system is tested to 11 Bar in hyperbaric chamber. The acoustical data link is first established between two computers located at surface to test the reliability of the communication. The acoustical link experiments were successful for 20 minutes of simulated signals for the depth, interstitial glycaemia, breathing frequency and temperature information. The overall efficiency was 80.1%, with 474 bytes sent and 378 bytes received. The bandwidth of the acoustical link is very low max 4 reading/min but is adequate for glycaemia monitoring that can be as low as 1 reading every 5 minutes. Finally the system recorded the interstitial glucose of divers in 8 open water dives successfully and will be beneficial for studying diabetic divers. The system has a potential to be used to verify and optimize the existing protocols on diabetic divers. It offers as well an emergency system to monitor the non-diabetic divers during extreme exposures such as saturation diving.

🔖

Bu Makaleye Atıf Yap

ÖZYİĞİT, T., PİERLEONİ, P., EGİ, S. M., ALTEPE, C., PIERI, M., SİNOPLU, D. R., CİALONİ, D., MARRONİ, A. (2022). Design and Implementation of an Underwater Telemetric Glucose Monitoring System for Scuba Divers. Hittite Journal of Science and Engineering, Cilt: 5 - Sayı: 2, 141–146. https://ajindex.com/articles/538021

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (15)

  1. Pollock, NW, Uguccioni, DM, Dear, GdeL. (Eds.). Diabetes and recreational diving: guidelines for the future. Proceedings of the UHMS/DAN Workshop, Durham, NC, 19 June, Divers Alert Network, 136 p, 2005
  2. Pieri, M, Cialoni, C, Marroni, A. Continuous real-time monitoring and recording of glycemia during scuba diving: pilot study. Undersea Hyperb Med 43 (2016) 265–272
  3. Baggeroer. AB. Acoustic telemetryan overview. IEEE J Oceanic Engineering 9 (1984) 229–235
  4. Fell, RB, Skutt, HR, Waterfield, A. Four-channel ultrasonic telemetry system for obtaining physiological data from ocean divers. Biotelemetry 1 (1974) 50-59
  5. Gooden, BA, Feinstein, R, Skutt HR. Heart rate responses of scuba divers via ultrasonic telemetry. Undersea Biomed Res 2 (1975) 11–19
  6. Istepanian, RHS. Use of microcontrollers for diver monitoring by underwater acoustic biotelemetry in multipath environments. PhD thesis, Loughborough Univ. U.K., 1994
  7. Woodward, B, Istepanian, RSH. Physiological monitoring by underwater ultrasonic biotelemetry. J. Soc. Underwater Technol 18 (1992) 34–44
  8. Egi, SM. Design of an acoustic telemetry system for rebreathers. Undersea Hyperb Med 36 (2009) 65–71
  9. Vaganay J, Baccou P, Jouvencel B. Homing by acoustic ranging to a single beacon. Proceedings OCEANS 2000 MTS/IEEE Conference, 3 (2000), 1457-1462
  10. Black, S. wixel-xdrip. https://github.com/ StephenBlackWasAlreadyTaken/wixelxDrip, 2015. Access date: 20.08.2017
  11. In vitro diagnostic test systems -- Requirements for bloodglucose monitoring systems for self-testing in managing diabetes mellitus. ISO 15197:2013
  12. Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL. Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care 10 (1987) 622–628 13. https://www.pololu.com/product/1336. Access date: 14.11.2017. 14. h t t p: //w w w. i n n o v a s u b. c o m /p a g e s /d e c o p a g e. aspx?pro=uepm_d_board. Access date: 14.11.2017
  13. Davis J, Bove AA. Medical Evaluation for Sport Diving. In: Bove AA, ed. Diving Medicine, 3rd ed. Philadelphia, PA: WB Saunders Co.; 1997: 355-6
  14. USA Public Law 101-336; 104 Stat. 327; 1990 17. Dear G de L, Pollock NW, Uguccioni DM, Dovenbarger J, Feinglos MN, Moon, RE. Plasma glucose responses in recreational divers with insulin-requiring diabetes. Undersea Hyperb Med 2004; 31(3)291-301
  15. The Expert Committee on the Diagnosis and Classification of Diabetes Mellitus. Report of the Expert Committee on the Diagnosis