Dergiler / Annals of Medical Research / 2020 / Cilt: 27 - Sayı: 3

Clinical results of volar locking plate fixation in radius distal fractures

Sayfa
805–809
Yayın Tarihi
2022-10-12
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

It should be considered as treatment of choicefor all but especially active and demanding patients.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Aim: This study aimed to evaluate the results of 41 surgically treated radius distal fracture patients.
📊
Temel Bulgular & Veri:Average follow-up time was 9.8months (6-19) and mean age was 44.04 (20-81).
💡
Sonuç & Katkı:It should be considered as treatment of choicefor all but especially active and demanding patients.
🔬Tür:Araştırma Makalesi
📍Kapsam:2018 Verileri
⚙️Değişkenler:Alan Parametreleri

Abstract

Aim: This study aimed to evaluate the results of 41 surgically treated radius distal fracture patients. Average follow-up time was 9.8months (6-19) and mean age was 44.04 (20-81). All patients treated surgically with volar locking plate between the dates October2010 and November 2018.Material and Methods: There were 11 type A2 (26%), 10 type C2 (24%), 4 type A3 (9%), 3 type B1 (7%), 3 type B3 (8%), 6 type C3(14%) and 4 type C1 (9%) fractures, respectively according to the AO Classification System. Stewart’s radiological criteria and rangeof motion were used in clinical and radiological evaluation. QuickDASH-T and Gartland-Werley scores were used for functionalassessment.Results: Twenty-three patients (56%) had excellent, 14 patients (34%) had good and 4 patients (9%), respectively had moderatefunctional scores according to Gartland-Werley scoring scale. Thirty-four patients (83%) were excellent and 7 patients (17%) weregood, respectively according to Stewart’s radiological criteria. Average QuickDASH-T score was 5.92 (0-22.7) and average GartlandWerley score was 3.26 (0-13). Two patients suffered reflex sympathetic dystrophy as a complication.Conclusion: Volar locking plating in distal radius fractures is a reliable treatment method with successful results with carefulpreoperative planning, attentive surgical approach and systematical rehabilitation. It should be considered as treatment of choicefor all but especially active and demanding patients.

🔖

Bu Makaleye Atıf Yap

UMUR, L., SARI, E. (2022). Clinical results of volar locking plate fixation in radius distal fractures. Annals of Medical Research, Cilt: 27 - Sayı: 3, 805–809. https://ajindex.com/articles/446455

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (15)

  1. KJ Koval, JJ Harrast, JO Anglen et al. “Fractures of the distal part of the radius: The evolution of practice over time. Where’s the evidence?,” J Bone J Surg 2008;90:1855-61
  2. JB Jupiter. “Fractures of the distal end of the radius.,” J Bone Jt Surg 1991;73:461-9
  3. R Sevimli, “Efficacy of compression application in instable intraarticular distal radius fractures, treated with external fixator,”. Sci Res Essays 2014;9:722-9
  4. F Wichlas, NP Haas, A Disch, et al. “Complication rates and reduction potential of palmar versus dorsal locking plate osteosynthesis for the treatment of distal radius fractures,” J Ortho. Traumatol 2014;15:259-64
  5. J Orbay. “Volar plate fixation of distal radius fractures,” Hand Clin 2005;21;347-54
  6. NC Chen and JB Jupiter. “Management of distal radial fractures,” J. Bone Jt Surg 2007;89:2051-62
  7. L Obert. “Fixation of distal radius fractures in adults: A review,” Orthop. Traumatol Surg Res 2013;99:216-34, 8. M Fok, M Klausmeyer, D Fernandez, et al.“Volar Plate Fixation of Intra-Articular Distal Radius Fractures: A Retrospective Study,” J Wrist Surg 2013;2:247-54
  8. PD Gallacher, R Gilbert, S Memon, et al.“Volar plating of distal radius fractures using a locked anatomically contoured plate,” Eur J Orthop Surg Traumatol 2010;20:11-5
  9. J Imatani, K Akita, K Yamaguchi, et al.“An anatomical study of the watershed line on the volar, distal aspect of the radius: Implications for plate placement and avoidance of tendon ruptures,” J Hand Surg Am 2012;37:1550-4
  10. P Esenwein, J Sonderegger, J Gruenert, et al. “Complications following palmar plate fixation of distal radius fractures: A review of 665 cases,” Arch. Orthop Trauma Surg 2013;133;1155-62
  11. L B Wall, MD Brodt, MJ Silva, et al. “The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates,” J Hand Surg Am 2012;37: 446-53
  12. AP Riddick, B Hickey, SP White. “Accuracy of the skyline view for detecting dorsal cortical penetration during volar distal radius fixation,” J Hand Surg Eur Vol 2012;37:407-41
  13. RH Brumfield and JA Champoux. “A biomechanical study of normal functional wrist motion,” Clin Orthop Relat Res 1984;187: 23-5
  14. JL Orbay and DL Fernandez. “Volar Fixation for Dorsally Displaced Fractures of the Distal Radius: A Preliminary Report,” J Hand Surg Am 2002;27:205-15
  15. A Bentohami, K De Burlet, N De Korte, et al.Goslings, and N. W. L. Schep, “Complications following volar locking pl