Dergiler / Anadolu Üniversitesi Bilim ve Teknoloji Dergisi :A-Uygulamalı Bilimler ve Mühendislik / 2017 / Cilt: 18 - Sayı: 1

A NOVEL GEL ELECTROLYTE FOR VALVE-REGULATED LEAD ACID BATTERY

Sayfa
146–160
Yayın Tarihi
2022-10-11
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

TiO can be a useful additive for gel-VRLA batteries.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:A novel gel electrolyte system used in lead-acid batteries was investigated in this work.
📊
Temel Bulgular & Veri:The gel systems were prepared by addition of different amount of Al2O3, TiO2 and B2O3 into the gelled system consisting of 6 wt% fumed silica and 30 wt% sulfuric acid solution for the first time.
💡
Sonuç & Katkı:TiO can be a useful additive for gel-VRLA batteries.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

A novel gel electrolyte system used in lead-acid batteries was investigated in this work. The gel systems were prepared by addition of different amount of Al2O3, TiO2 and B2O3 into the gelled system consisting of 6 wt% fumed silica and 30 wt% sulfuric acid solution for the first time. The anodic peak currents and peak redox capacities of the gel electrolytes were characterized by cyclic voltammetric method. When B2O3 and Al2O3 were used as additives in fumed silica based gel electrolyte system, the anodic peak currents and peak redox capacities decreased. However, the investigated parameters in cyclic voltammetry (anodic peak current and capacities) increased by the adding of 3.0 wt% of TiO2 in the fumed silica based gel system. The solution and charge transfer resistances of the gel electrolytes were investigated by electrochemical impedance spectroscopy. While the solution resistances were lower in gel systems having different amount additives than pure fumed silica based gel, the charge transfer resistance was the lowest in gel electrolytes consisting fumed silica and fumed silica-TiO2. The morphological differences of gelled systems were elucidated by scanning electron microscopic and optic microscopic analysis. The battery performances were studied by obtaining discharge curves of prepared gel electrolytes. The performance of gelled systems were higher than that of non-gelled electrolyte at room temperature. The mixture of fumed silica-TiO2 was suggested an alternative gel formulation for gel valve-regulated lead acid batteries. TiO can be a useful additive for gel-VRLA batteries.

🔖

Bu Makaleye Atıf Yap

ŞAHİN, Y., DÖNMEZ, K. B., GENÇTEN, M. (2022). A NOVEL GEL ELECTROLYTE FOR VALVE-REGULATED LEAD ACID BATTERY. Anadolu Üniversitesi Bilim ve Teknoloji Dergisi :A-Uygulamalı Bilimler ve Mühendislik, Cilt: 18 - Sayı: 1, 146–160. https://ajindex.com/articles/438266

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (15)

  1. Ohmae T, Sawai K, Shiomi M, Osumi S. Advanced technologies in VRLA batteries for automotive applications. J Power Sources 2006; 154: 523-529
  2. Tsujikawa T, Matsushima, T. Remote monitoring of VRLA batteries for telecommunications systems. J Power Sources 2007, 168: 99-104
  3. Chang Y, Mao X, Zhao Y, Feng S, Chen H, Finlow D. Lead-acid battery use in the development of renewable energy systems in China. J Power Sources 2009; 191: 176-183
  4. Lambert D.W. H, Greenwood P. H. J, Reed M. C. Advances in gelled-electrolyte technology for valve-regulated lead-acid batteries. J Power Sources 2002; 107: 173-179
  5. Wagner R. High-power lead-acid batteries for different applications. J Power Sources 2005; 144: 494-504
  6. May G. J, Calasanzio D, Aliberti R. VRLA automotive batteries for stop&go and dual battery systems. J Power Sources 2005; 144: 411-417
  7. Clement N. Use of synthetic fibre reinforcement for improving the performance of AGM separators for VRLA batteries. J. Power Sources 2004; 133: 87-93
  8. Prengamani, R. D. Improvements to active material for VRLA batteries. J Power Sources 2005; 144: 426-437
  9. Martha S.K, Hariprakash B, Gaffoor S.A, Ambalavanan S, Shukla A.K. Performance characteristics of a gelled-electrolyte valve-regulated lead-acid battery. Bull Mater Sci 2003; 26:465-469
  10. Bhattacharya A, Basumallick I. N. Effect of mixed additives on lead-acid battery electrolyte. J Power Sources 2003; 113: 382-387
  11. Tantichanakul T, Chailapakul O, Tantavichet N. Influence of fumed silica and additives on the gel formation and performance of gel valve-regulated lead-acid batteries. J Ind Eng Chem 2013; 19: 2085-2091
  12. Chen M.Q, Chen H. Y, Shu D, Li A.J, Finlow D.E. Effects of preparation condition and particle size distribution on fumed silica gel valve-regulated lead-acid batteries performance. J Power Sources 2008; 181: 161-171
  13. Chen M, Guo W, Zhang M, Cheng F, Liu P, Cai Z, Zhang Y. Effect of polyols on the electrochemical behavior of gel valve-regulated lead-acid batteries. Electrochim Acta 2015; 164:243- 251
  14. Pan K, Shi G, Li A, Li H, Zhao R, Wang F, Zhang W, Chen Q, Chen H, Xiong Z, Finlow D. The performance of a silica-based mixed gel electrolyte in lead acid batteries. J Power Sources 2012; 209: 262-268
  15. Gençten M, Dönmez K.B, Şahin Y, Pekmez K, Suvacı E. Voltammetric and electrochemical impedimetric behavior of silica-based gel electrolyte for valve-regulated lead-acid battery. J Solid State Electrochem 20