Supercritical Steam Power Cycle For Line-Focusing Solar Power Plants

Sayfa
219–225
Yayın Tarihi
2015-12-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Seven feed-water heaters optimized the plant performance power output

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:A recent study between Sandia National Laboratories and Siemens Energy, Inc., published on March 2013 [11], confirmed the feasibility of adapting the Siemens turbine SST-900 for supercritical steam in concentrated solar power plants, with a live steam conditions 230-260 bar and output range between 140-200 MWe.
📊
Temel Bulgular & Veri:The design-point conditions were 550ºC and 260 bar at turbine inlet, and 165 MWe Gross power output.
💡
Sonuç & Katkı:Seven feed-water heaters optimized the plant performance power output
🔬Tür:Araştırma Makalesi
📍Kapsam:2013 Verileri
⚙️Değişkenler:Supercritical water · Supercritical Rankine · Direct Steam Generation

Abstract

A recent study between Sandia National Laboratories and Siemens Energy, Inc., published on March 2013 [11], confirmed the feasibility of adapting the Siemens turbine SST-900 for supercritical steam in concentrated solar power plants, with a live steam conditions 230-260 bar and output range between 140-200 MWe. In this context, this analysis is focused on integrating a linefocus solar field with a supercritical Rankine power cycle. For this purpose two heat transfer fluids were assessed: direct steam generation and molten salt HITEC XL. The design-point conditions were 550ºC and 260 bar at turbine inlet, and 165 MWe Gross power output. Plant performance was assessed at design-point in the supercritical power plant (between 43-45% net plant efficiency depending on balance of plant configuration), and in the subcritical plant configuration (~40% net plant efficiency with one DRH, and up to ~41% with two DRH stages). Direct Reheating was adopted in Rankine power cycle to avoid any intermediate heat exchanger. Seven feed-water heaters optimized the plant performance power output

🔖

Bu Makaleye Atıf Yap

Enrıquez, L. C., Anton, J. M., Martınez-val, J. M. (2015). Supercritical Steam Power Cycle For Line-Focusing Solar Power Plants. Politeknik Dergisi, Cilt: 18 Sayı: 4, 219–225. https://ajindex.com/articles/422381