Dergiler / Politeknik Dergisi / 2016 / Cilt: 19 Sayı: 4

An Investigation on Shielding Effect of Bismuth on Lung Ct Scan Using Monte Carlo Simulation

Sayfa
617–622
Yayın Tarihi
2016-12-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

It can be concluded from MC results that the bismuth shielding reduced lung dose significantly in x-ray CT examination of thorax region

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Computed tomography (CT) related to computer-processed combination or X-ray images obtained from different angles to create patient’s cross-sectional body parts images.
📊
Temel Bulgular & Veri:MCNPX (version 2.4.0) has been used during the calculations.
💡
Sonuç & Katkı:It can be concluded from MC results that the bismuth shielding reduced lung dose significantly in x-ray CT examination of thorax region
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Dose Reduction · Bismuth Shielding · Monte Carlo

Abstract

Computed tomography (CT) related to computer-processed combination or X-ray images obtained from different angles to create patient’s cross-sectional body parts images. CT is mostly associated with high radiation dose to organs during the diagnostic process. To provide the probable effect of bismuth shielding on dose reduction to organs and investigation of applicability of Monte Carlo (MC) method. Monte Carlo (MC) method has been used for calculation of dose attenuation properties of bismuth. MCNPX (version 2.4.0) has been used during the calculations. In this study, validation of modeled MCNPX simulation geometry has been provided by calculating the mass attenuation coefficient values of lung and comparing with previous available studies in literature for lung. Our results agreed well with other results about mass attenuation coefficients of lung. By using the validated MC model, dose attenuation properties of bismuth have been investigated. Dose reduction rates of bismuth on lung have been compared with experimental studies. With bismuth shielding, absorbed dose amount in lung significantly reduced. It can be concluded from MC results that the bismuth shielding reduced lung dose significantly in x-ray CT examination of thorax region

🔖

Bu Makaleye Atıf Yap

Tekin, H. O., Manici, T., Sıngh, V. P. (2016). An Investigation on Shielding Effect of Bismuth on Lung Ct Scan Using Monte Carlo Simulation. Politeknik Dergisi, Cilt: 19 Sayı: 4, 617–622. https://ajindex.com/articles/422320

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...