Dergiler / Turkish Journal of Physics / 2021 / Cilt: 45 - Sayı: 5

Thermal sensitivity from current-voltage-measurement temperaturecharacteristics in Au/n-GaAs Schottky contacts

Sayfa
268–280
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The linearity of the voltage vs temperature and the α vs current graphs is a very crucial key factor of a good thermal sensor in the thermal sensitivity

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:We have measured the current–voltage-temperature (I-V-T) characteristics of the Au/n-GaAs/In Schottky barrier diodes (SBDs) to introduce their thermal sensitivity mechanism.
📊
Temel Bulgular & Veri:The diode showed high and decisive thermal sensitivity up to a current level of 0.10 pA.
💡
Sonuç & Katkı:The linearity of the voltage vs temperature and the α vs current graphs is a very crucial key factor of a good thermal sensor in the thermal sensitivity
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

We have measured the current–voltage-temperature (I-V-T) characteristics of the Au/n-GaAs/In Schottky barrier diodes (SBDs) to introduce their thermal sensitivity mechanism. The forward bias voltage variation with temperature (thermal sensitivity) of this SBDs has been studied at different constant current levels. The diode showed high and decisive thermal sensitivity up to a current level of 0.10 pA. The bias voltage-temperature (V-T) curves of the SBD have showed an excellent linear behavior at all current levels. The slope dV/dT = α or the thermal sensitivity coefficient α from the V-T curves decreased from 3.42 mV/K at 0.10 pA to 1.31 mV/K at 10 mA with increasing current level. Furthermore, the α versus current graph of the diode has given a straight line from 0.10 pA to 10 mA whose intercept α0 and slope dα/dI values have been obtained as 2.65 mV/K and -0.081 mV/(AK). The linearity of the voltage vs temperature and the α vs current graphs is a very crucial key factor of a good thermal sensor in the thermal sensitivity

🔖

Bu Makaleye Atıf Yap

TURUT, A., EFEOĞLU, H. (2021). Thermal sensitivity from current-voltage-measurement temperaturecharacteristics in Au/n-GaAs Schottky contacts. Turkish Journal of Physics, Cilt: 45 - Sayı: 5, 268–280. https://ajindex.com/articles/408559

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (1)

  1. S. Demirezen, H.G. Cetinkaya, M. Kara, F. Yakuphanoglu and S. Altındal, Synthesis, electrical and photo-sensing characteristics of theAl/(PCBM/NiO: ZnO)/p-Si nanocomposite structure, Sensors and Actuators A: Physical 317, 112449 (2021). doi: 10.1016/j.sna.2020.112449 [2] A. Türüt, On current-voltage and capacitance-voltage characteristics of metal-semiconductor contacts, Turkish Journal of Physics 44, 302–347 (2020). doi: 10.3906/fiz-2007-11 [3] E.H. Rhoderick, Metal-semiconductor contacts, E. H. IEE Proceeding, Solid State and Electron Devices 129 (1982). doi: 10.1049/ip-i-1.1982.0001 [4] M.S. Gorji and K. Y. Cheong, Embedded nanoparticles in schottky and ohmic contacts: A review, Crit. Rev. Solid State Mater Sci. 40, 197-222 (2015). doi: 10.1080/10408436.2014.940444 [5] G. Brezeanu, F. Draghici, F. Craciunioiu, C. Boianceanu, F. Bernea, F. Udrea, D. Puscasu and I. Rusu, 4H-SiC Schottky diodes for temperature sensing applications in harsh environments, Materials Science Forum 679–680, 575–578 (2011). doi: 10.4028/www.scientific.net/MSF.679-680.575 [6] G. Pristavu, G. Brezeanu, R. Pascu, F. Drăghici and M. Bădilă, Characterization of non-uniform Ni/4H-SiC Schottky diodes for improved responsivity in high-temperature sensing, Materials Science in Semiconductor Processing 94, 64–69, (2019). doi: 10.1016/j.mssp.2019.01.018 [7] Q. Guo, F. Lu, Q. Tan, T. Zhou, J. Xiong and W. Zhang, Al2O3 -based a-IGZO Schottky Diodes for temperature sensing, Sensors 19, 224 (2019). doi: 10.3390/s19020224. [8] N. Marcano, A. Singh and F. Perez, Voltage-temperature characteristics of W/n-GaAs Schottky diodes activated by the constant forward current: application as temperature sensors, Proceedings of the second IEEE International Caracas Conference on Devices, Circuits and Systems (Cat. No.98TH8350), 88-91 (1998). doi: 10.1109/ICCDCS.1998.705812. [9] N.G. Filonov, A Stable Temperature Sensor Based on GaAs Structures with Schottky Barriers, Instruments and Experimental Techniques 45, 412–415, (2002). doi: 10.1023/A:1016088110238. [10] V. Kumar, S. Pawar, A.S. Maan and J. Akhtar, Diameter dependent thermal sensitivity variation trend in Ni/4HSiC Schottky diode temperature sensors, Journal of Vacuum Science & Technology B 33, 052207 (2015). doi: 10.1116/1.4929890 [11] V. Kumar, J. Verma, A.S. Maan and J. Akhtar, Epitaxial 4H–SiC based Schottky diode temperature sensors in ultra-low current range, Vacuum 182, 109590, (2020). doi: 10.1016/j.vacuum.2020.109590. [12] L. Di Benedett