Dergiler / Turkish Neurosurgery / 2019 / Cilt: 29 - Sayı: 1

How to Reduce Stress on the Pedicle Screws in Thoracic Spine? Importance of Screw Trajectory: A Finite Element Analysis

Sayfa
20–25
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

In addition, we believe that AT could protect against screw loosening because the von-Mises stress of the internal fixationwas scattered.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:AIM: To investigate the biomechanical comparison of thoracic transpedicular screw trajectories on the sagittal plane.MATERIAL and METHODS: A three-dimensional, non-linear finite element analysis (FEA) model of T8 through T9 was used.Anatomic trajectory (AT) and Straightforward trajectory (ST) models of the transpedicular screws were used in the intact FEA model.The von-Mises stress and range of motion (ROM) of the transpedicular screws were evaluated.RESULTS: The difference in ROM between both techniques was negligible.
📊
Temel Bulgular & Veri:In lateral bending and axial rotation, FEA showeddecrease in stress by 25% and 8%, respectively, when pedicle screws were placed using AT.CONCLUSION: AT decreased the von-Mises stress of the pedicle screws, thereby reducing the rates of screw breakage and fatiguerisks.
💡
Sonuç & Katkı:In addition, we believe that AT could protect against screw loosening because the von-Mises stress of the internal fixationwas scattered.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

AIM: To investigate the biomechanical comparison of thoracic transpedicular screw trajectories on the sagittal plane.MATERIAL and METHODS: A three-dimensional, non-linear finite element analysis (FEA) model of T8 through T9 was used.Anatomic trajectory (AT) and Straightforward trajectory (ST) models of the transpedicular screws were used in the intact FEA model.The von-Mises stress and range of motion (ROM) of the transpedicular screws were evaluated.RESULTS: The difference in ROM between both techniques was negligible. In lateral bending and axial rotation, FEA showeddecrease in stress by 25% and 8%, respectively, when pedicle screws were placed using AT.CONCLUSION: AT decreased the von-Mises stress of the pedicle screws, thereby reducing the rates of screw breakage and fatiguerisks. In addition, we believe that AT could protect against screw loosening because the von-Mises stress of the internal fixationwas scattered.

🔖

Bu Makaleye Atıf Yap

GUVENC, Y., AKYOLDAS, G., SENTURK, S., ERBULUT, D., YAMAN, O., OZER, A. F. (2019). How to Reduce Stress on the Pedicle Screws in Thoracic Spine? Importance of Screw Trajectory: A Finite Element Analysis. Turkish Neurosurgery, Cilt: 29 - Sayı: 1, 20–25. https://ajindex.com/articles/404396

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (1)

  1. Asher MA, Carson WL, Hardacker JW, Lark RG, Lai SM: The effect of arthrodesis, implant stiffness, and time on the canine lumbar spine. J Spinal Disord Tech 20:549–559, 2007 2. Ashman RB, Galpin RD, Corin JD, Johnston CE: Biomechanical analysis of pedicle screw instrumentation systems in a corpectomy model. Spine 14:1398–1405, 1989 3. Belmont PJ Jr, Klemme WR, Dhawan A, Polly DW Jr: In vivo accuracy of thoracic pedicle screws. Spine 26:2340–2346, 2001 4. Benzel EC, Baldwin NG: Crossed-screw fixation of the unstable thoracic and lumbar spine. J Neurosurg 82:11–16, 1995 5. Boos N, Webb JK: Pedicle screw fixation in spinal disorders: A European view. Eur Spine J 6:2–18, 1997 6. Boucher HH: A method of spinal fusion. J Bone Joint Surg Br 41:248–259, 1959 7. Brodke DS, Bachus KN, Mohr RA, Nguyen BK: Segmental pedicle screw fixation or cross-links in multilevel lumbar constructs. A biomechanical analysis. Spine J 1:373–379, 2001 8. Chao CK, Hsu CC, Wang JL, Lin J: Increasing bending strength and pullout strength in conical pedicle screws: Biomechanical tests and finite element analyses. J Spinal Disord Tech 21: 130-138, 2008 9. Cho W, Cho SK, Wu C: The biomechanics of pedicle screwbased instrumentation. J Bone Joint Surg 92-B: 1061-1065, 2010 10. Davne SH, Myers DL: Complications of lumbar spinal fusion with transpedicular instrumentation. Spine (Phila Pa 1976) 17: S184–S189, 1992 11. Dhawan A, Klemme WR, Polly DW Jr: Thoracic pedicle screws: Comparison of start points and trajectories. Spine (Phila Pa 1976) 33(24): 2675-2681, 2008 12. El Saman A, Meier S, Sander A, Kelm A, Marzi I, Laurer H: Reduced loosening rate and loss of correction following posterior stabilization with or without PMMA augmentation of pedicle screws in vertebral fractures in the elderly. Eur J Trauma Emerg Surg 39(5):455–460, 2013 13. Erbulut DU: Biomechanical effect of graded facetectomy on asymmetrical finite element model of the lumbar spine. Turk Neurosurg 24(6): 923-928, 2014 14. Farshad M, Farshad-Amacker NA, Bachmann E, Snedeker JG, Schmid SL: Biomechanical comparison of sagittal-parallel versus non-parallel pedicle screw placement. Acta Neurochir (Wien) 156(11): 2147-2151, 2014 15. Ha KY, Kim KW, Chang CH, Ha JY: Changes of fixation strength by rod-contouring of compact Cotrel-Dubousset instrumentation. J Korean Orthop Assoc 33: 1134–1139, 1998 16. Huiskes R, Weinans H, van Rietbergen B: The relationship between stress shielding and bone resorption around total hip stems and the