Dergiler / Turkish Journal of Chemistry / 2002 / Cilt: 26 - Sayı: 5

Determination of Calcium, Magnesium and Aluminium in Magmatic Rocks after Ultrasonic Leaching by Flame AAS

Sayfa
711–724
Yayın Tarihi
2002-05-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The following recovery ratios were obtained for Ca, Mg and Al, respectively. 96% < K1, Ca < 112% and 95% < K2, Ca < 112%, 93% < K1, Mg < 109% and 94% < K2, Mg < 108% and 91% < K1, Al < 102% and 94% < K2, Al < 107%.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:A method of ultrasonic leaching has been developed for the destructive analysis of magmatic rock samples1.
📊
Temel Bulgular & Veri:The accuracy of the ultrasonic leaching method (CULM) was tested using standard reference materials (SRMs) and the recovery ratio as K1 = CULM/CSRM was defined.
💡
Sonuç & Katkı:The following recovery ratios were obtained for Ca, Mg and Al, respectively. 96% < K1, Ca < 112% and 95% < K2, Ca < 112%, 93% < K1, Mg < 109% and 94% < K2, Mg < 108% and 91% < K1, Al < 102% and 94% < K2, Al < 107%.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Ultrasonic metal leaching · partial leaching · magmatic rocks

Özet

A method of ultrasonic leaching has been developed for the destructive analysis of magmatic rock samples1. This method was applied to determine three new elements, Ca, Mg and Al, in magmatic rock samples. The accuracy of the ultrasonic leaching method (CULM) was tested using standard reference materials (SRMs) and the recovery ratio as K1 = CULM/CSRM was defined. Another recovery ratio, K2, was also defined from the results of the conventional dissolution method (CDM), that is K2 = CULM/CCDM. The accuracy and precision of the method are comparable with those of conventional methods. The following recovery ratios were obtained for Ca, Mg and Al, respectively. 96% < K1, Ca < 112% and 95% < K2, Ca < 112%, 93% < K1, Mg < 109% and 94% < K2, Mg < 108% and 91% < K1, Al < 102% and 94% < K2, Al < 107%.

Abstract

A method of ultrasonic leaching has been developed for the destructive analysis of magmatic rock samples1. This method was applied to determine three new elements, Ca, Mg and Al, in magmatic rock samples. The accuracy of the ultrasonic leaching method (CULM) was tested using standard reference materials (SRMs) and the recovery ratio as K1 = CULM/CSRM was defined. Another recovery ratio, K2, was also defined from the results of the conventional dissolution method (CDM), that is K2 = CULM/CCDM. The accuracy and precision of the method are comparable with those of conventional methods. The following recovery ratios were obtained for Ca, Mg and Al, respectively. 96% < K1, Ca < 112% and 95% < K2, Ca < 112%, 93% < K1, Mg < 109% and 94% < K2, Mg < 108% and 91% < K1, Al < 102% and 94% < K2, Al < 107%.

🔖

Bu Makaleye Atıf Yap

AKÇAY, M. H. Ö. A. M. (2002). Determination of Calcium, Magnesium and Aluminium in Magmatic Rocks after Ultrasonic Leaching by Flame AAS. Turkish Journal of Chemistry, Cilt: 26 - Sayı: 5, 711–724. https://ajindex.com/articles/397795

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...