Conclusion: Within the limitations in this study, 100 g and 200 g forces can be applied because both seating forces showed acceptable SBS results

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objective: The purpose of this study was to observe two different seating forces on conventional and self-ligating brackets using shear bond strength (SBS).Methods: The study material consisted of 48 recently extracted human premolars divided into four groups: Group I, conventional bracket (Master series, AO) 100 g seating force applied; Group II, conventional bracket (Master series, AO) 200 g seating force applied; Group III, self-ligating bracket (Empower, AO) 100 g seating force applied; and Group IV, self-ligating bracket (Empower, AO) 200 g seating force applied.
📊
Temel Bulgular & Veri:Following the bonding procedure, all teeth were stored in deionized water at 37°C for 30 days, and they were thermal cycled.
💡
Sonuç & Katkı:Conclusion: Within the limitations in this study, 100 g and 200 g forces can be applied because both seating forces showed acceptable SBS results
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Objective: The purpose of this study was to observe two different seating forces on conventional and self-ligating brackets using shear bond strength (SBS).Methods: The study material consisted of 48 recently extracted human premolars divided into four groups: Group I, conventional bracket (Master series, AO) 100 g seating force applied; Group II, conventional bracket (Master series, AO) 200 g seating force applied; Group III, self-ligating bracket (Empower, AO) 100 g seating force applied; and Group IV, self-ligating bracket (Empower, AO) 200 g seating force applied. All teeth were bonded with Transbond XT by the same operator. Following the bonding procedure, all teeth were stored in deionized water at 37°C for 30 days, and they were thermal cycled. A universal testing machine was used to obtain the SBS records. The Kruskal–Wallis statistical test was used to determine the significant differences in SBS between the four groups, and the Mann–Whitney U test with Bonferroni correction was used to compare the subgroups.Results: The mean shear bond strength was 15.70 MPa for Group I, 13.97 MPa for Group II, 8.38 MPa for Group III, and 8.31 MPa for Group IV. Significant differences in the SBS values were recorded between the self-ligating groups and conventional bracket groups. Seating forces on the brackets did not show any differences among the groups. Conclusion: Within the limitations in this study, 100 g and 200 g forces can be applied because both seating forces showed acceptable SBS results

🔖

Bu Makaleye Atıf Yap

SÖKÜCÜ, O., YEŞİLDAL, S., OKŞAYAN, R., ŞİMŞEK, İ. (2016). Does the Seating Force Affect the Shear Bond Strength of Brackets? An InVitro Study. Turkish Journal of Orthodontics, Cilt: 29 - Sayı: 1, 6–9. https://ajindex.com/articles/375032

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (15)

  1. Tavares SW, Consani S, Nouer DF, Magnani MB, Nouer PR, Martins LM. Shear bond strength of new and recycled brackets to enamel. Braz Dent J 2006
  2. [CrossRef ] 2. Northrup RG, Berzins DW, Bradley TG, Schuckit W. Shear bond strength comparison between two orthodontic adhesives and self-ligating and conventional brackets. Angle Orthod 2007
  3. [CrossRef ] 3. Katona TR, Long RW. Effect of loading mode on bond strength of orthodontic brackets bonded with 2 systems. Am J Orthod Dentofacial Orthop 2006
  4. [CrossRef ] 4. Sokucu O, Siso SH, Ozturk F, Nalcaci R. Shear Bond Strength of Orthodontic Brackets Cured with Different Light Sources under Thermocycling. Eur J Dent 2010
  5. Oztoprak MO, Isik F, Sayinsu K, Arun T, Aydemir B. Effect of blood and saliva contamination on shear bond strength of brackets bonded with 4 adhesives. Am J Orthod Dentofacial Orthop 2007
  6. [CrossRef] 6. İşman E, Karaarslan E, Okşayan R, Tunçdemır AR, Üşümez S, Adanir N, et al. Inadequate shear bond strengths of self-etch, self-adhesive systems for secure orthodontic bonding. Dent Mater J 2012
  7. [CrossRef] 7. Thomas RG. Indirect bonding: simplicity in action. J Clin Orthod 1979
  8. Thompson MA, Drummond JL, BeGole EA. Bond strength analysis of custom base variables in indirect bonding techniques. Am J Orthod Dentofacial Orthop 2008
  9. 9 e15-20. 9. Muguruma T, Yasuda Y, Iijima M, Kohda N, Mizoguchi I. Force and amount of resin composite paste used in direct and indirect bonding. Angle Orthod 2010
  10. [CrossRef ] 10. Harradine NW. Self-ligating brackets: where are we now? J Orthod 2003
  11. [CrossRef ] 11. Harradine NW. Self-ligating brackets and treatment efficiency. Clinic Orthod Res 2001
  12. [CrossRef ] 12. Scott P, DiBiase AT, Sherriff M, Cobourne MT. Alignment efficiency of Damon3 self-ligating and conventional orthodontic bracket systems: a randomized clinical trial. Am J Orthod Dentofacial Orthop 2008
  13. 470 e1-8. 13. Harradine N. The history and development of self-ligating brackets. Semin Orthod 2008. p. 5-18. [CrossRef ] 14. Sfondrini MF, Xheka E, Scribante A, Gandini P, Sfondrini G. Reconditioning of self-ligating brackets. Angle Orthod 2012
  14. [CrossRef] 15. Chen SS, Greenlee GM, Kim JE, Smith CL, Huang GJ. Systematic review of self-ligating brackets. Am J Orthod Dentofacial Orthop 2010
  15. 726 e1- e18. 16. Finnema KJ, Ozcan M, Post WJ, Ren Y, Dijkstra PU. In-vitro