Dergiler / The Anatolian Journal of Cardiology / 2019 / Cilt: 21 - Sayı: 4

Comprehensive echocardiographic imaging of atrioventricular valves in children with atrioventricular septal defect: Accuracy of 2D and 3D imaging and reasons for disagreement

Sayfa
214–221
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

In most cases, where it was not possible to visualize the atrioventricular feature by 2D, it was possible by 3D, and vice versa.Conclusion: The accuracy of 2D and 3D echocardiography and understanding the potential reasons for disagreements in assessing the atrioventricular valve complex with 2D and 3D can guide the use of those two techniques when combining them in the clinical practice. (Anatol JCardiol 2019; 21: 214-21)

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objective: To compare the accuracy and reasons for disagreement of two-dimensional (2D) and three-dimensional (3D) echocardiography findings in the assessment of the atrioventricular valve complex in patients with atrioventricular septal defect.Methods: A total of 20 children (mean age 8 months) with atrioventricular septal defect were enrolled prospectively into this study.
📊
Temel Bulgular & Veri:The accuracyof and the reasons for disagreement in the assessment of the atrioventricular valve features were analyzed between 2D and 3D echocardiography and surgical findings.Results: We found that in assessing the Rastelli type and the extension of the inferior leaflet into the right ventricle, 3D echocardiography wasmore accurate compared to 2D echocardiography.
💡
Sonuç & Katkı:In most cases, where it was not possible to visualize the atrioventricular feature by 2D, it was possible by 3D, and vice versa.Conclusion: The accuracy of 2D and 3D echocardiography and understanding the potential reasons for disagreements in assessing the atrioventricular valve complex with 2D and 3D can guide the use of those two techniques when combining them in the clinical practice. (Anatol JCardiol 2019; 21: 214-21)
🔬Tür:Araştırma Makalesi
📍Kapsam:2019 Verileri
⚙️Değişkenler:Alan Parametreleri

Özet

Objective: To compare the accuracy and reasons for disagreement of two-dimensional (2D) and three-dimensional (3D) echocardiography findings in the assessment of the atrioventricular valve complex in patients with atrioventricular septal defect.Methods: A total of 20 children (mean age 8 months) with atrioventricular septal defect were enrolled prospectively into this study. The accuracyof and the reasons for disagreement in the assessment of the atrioventricular valve features were analyzed between 2D and 3D echocardiography and surgical findings.Results: We found that in assessing the Rastelli type and the extension of the inferior leaflet into the right ventricle, 3D echocardiography wasmore accurate compared to 2D echocardiography. In all other features, 2D and 3D echocardiography showed similar accuracy. A significant reason for inaccuracy by both echo modalities was that the technique itself could not visualize the feature, although the image quality was considered to be adequate. In most cases, where it was not possible to visualize the atrioventricular feature by 2D, it was possible by 3D, and vice versa.Conclusion: The accuracy of 2D and 3D echocardiography and understanding the potential reasons for disagreements in assessing the atrioventricular valve complex with 2D and 3D can guide the use of those two techniques when combining them in the clinical practice. (Anatol JCardiol 2019; 21: 214-21)

🔖

Bu Makaleye Atıf Yap

HAKACOVA, N., HIGGINS, T., MALM, T., WIERUP, P., MAYNARD, C., JOHANSSON, J. R. (2019). Comprehensive echocardiographic imaging of atrioventricular valves in children with atrioventricular septal defect: Accuracy of 2D and 3D imaging and reasons for disagreement. The Anatolian Journal of Cardiology, Cilt: 21 - Sayı: 4, 214–221. https://ajindex.com/articles/366789

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. Acar P, Laskari C, Rhodes J, Pandian N, Warner K, Marx G. Threedimensional echocardiographic analysis of valve anatomy as a determinant of mitral regurgitation after surgery for atrioventricular septal defects. Am J Cardiol 1999; 83: 745-9
  2. Fabricius AM, Walther T, Falk V, Mohr FW. Three-dimensional echocardiography for planning of mitral valve surgery: current applicability? Ann Thorac Surg 2004; 78: 575-8
  3. Simpson J, Lopez L, Acar P, Friedberg M, Khoo N, Ko H, et al. Threedimensional echocardiography in congenital heart disease: an expert consensus document from the European Association of Cardiovascular Imaging and the American Society of Echocardiography. Eur Heart J Cardiovasc Imaging 2016; 17: 1071-97
  4. Lange A, Palka P, Burstow DJ, Godman MJ. Three-dimensional echocardiography: historical development and current applications. J Am Soc Echocardiogr 2001; 14: 403-12
  5. Mori M, Yoshimuta T, Ohira M, Yagi M, Sakata K, Konno T, et al. Impact of real-time three-dimensional transesophageal echocardiography on procedural success for mitral valve repair. J Echocardiogr 2015; 13: 100-6
  6. Enriquez-Sarano M, Akins CW, Vahanian A. Mitral regurgitation. Lancet 2009; 373: 1382-94
  7. Studer M, Blackstone EH, Kirklin JW, Pacifico AD, Soto B, Chung GK, et al. Determinants of early and late results of repair of atrioventricular septal (canal) defects. J Thorac Cardiovasc Surg 1982; 84: 523-42. 8. van den Bosch AE, Ten Harkel DJ, McGhie JS, Roos-Hesselink JW, Simoons ML, Bogers AJ, et al. Surgical validation of real-time transthoracic 3D echocardiographic assessment of atrioventricular septal defects. Int J Cardiol 2006; 112: 213-8
  8. Kutty S, Colen TM, Smallhorn JF. Three-dimensional echocardiography in the assessment of congenital mitral valve disease. J Am Soc Echocardiogr 2014; 27: 142-54
  9. Yao C, Simpson JM, Schaeffter T, Penney GP. Multi-view 3D echocardiography compounding based on feature consistency. Phys Med Biol 2011; 56: 6109-28
  10. Adachi I, Uemura H, McCarthy KP, Ho SY. Surgical anatomy of atrioventricular septal defect. Asian Cardiovasc Thorac Ann. 2008; 16: 497-502
  11. Cabrera A, Pastor E, Galdeano JM, Modesto C, Cabrera JA, Alcibar J, et al. Cross-sectional echocardiography in the diagnosis of atrioventricular septal defect. Int J Cardiol 1990; 28: 19-23
  12. Minich LA, Snider AR, Bove EL, Lupinetti FM, Vermilion RP. Echocardiographic evaluation of atrioventricular orifice anatomy in children with atrioventricular septal defect. J