Dergiler / The European Research Journal / 2018 / Cilt: 4 - Sayı: 4

The use of doppler ultrasound in evaluation and follow-up of arteriovenous fistula patients

Sayfa
356–361
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusion: We believe that the DUS performed before AVF procedure would increase the primary patency rates of AVF created between the most convenient vessels and reduce the procedure failure.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objectives: The aim of the present study was to search the effect of preoperative Doppler ultrasonography (DUS) of the concerning limb on AVF patency for arteriovenous fistula (AVF) to be performed on the patients with end-stage renal disease.
📊
Temel Bulgular & Veri:Function of the AVF was controlled on the procedure day, at day 10, months 1, 3 and 6 as well as year 1 after the procedure.
💡
Sonuç & Katkı:Conclusion: We believe that the DUS performed before AVF procedure would increase the primary patency rates of AVF created between the most convenient vessels and reduce the procedure failure.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Hemodialysis · arteriovenous fistula · doppler ultrasonography

Abstract

Objectives: The aim of the present study was to search the effect of preoperative Doppler ultrasonography (DUS) of the concerning limb on AVF patency for arteriovenous fistula (AVF) to be performed on the patients with end-stage renal disease. Methods: One hundred and three patients were enrolled into the study. The exclusion criteria were previous central catheter procedure, history of thrombophlebitis on the upper limb and previous surgery on the upper limb. Among the remaining patients, those who fulfilled the physical examination criteria were included. The patients were divided into two groups as the control, DUS (-) group and the study group, DUS (+). The patients in the control group were taken into the procedure after a physical examination only. Brescio-Cimino method was preferred for all patients. Function of the AVF was controlled on the procedure day, at day 10, months 1, 3 and 6 as well as year 1 after the procedure. The results in both groups were statistically evaluated. Results: Twenty patients in the DUS (+) group (50% male, mean age: 57.25 ± 13.34 years) and 20 patients in the DUS (-) group (45% male, mean age: 56.10 ± 12.35) were recorded in the study. Cumulative primary patency rates between DUS (+) group and DUS(-) group for 12 months were 95% and 65%, respectively (log-rank, p = 0.022). Conclusion: We believe that the DUS performed before AVF procedure would increase the primary patency rates of AVF created between the most convenient vessels and reduce the procedure failure.

🔖

Bu Makaleye Atıf Yap

KAHRAMAN, N., ÖZSİN, K. K. (2018). The use of doppler ultrasound in evaluation and follow-up of arteriovenous fistula patients. The European Research Journal, Cilt: 4 - Sayı: 4, 356–361. https://ajindex.com/articles/364392

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. Rooijens PP, Burgmans JP, Yo TI, Hop WC, de Smet AA, van den Dorpel MA, et al. Autogenous radial-cephalic or prosthetic brachial-antecubital forearm loop AVF in patients with compromised vessels? A randomized, multicenter study of the patency of primary hemodialysis access. J Vasc Surg 2005;42:481-6
  2. Rahman A, Özsin KK. Upper extremity otogen arteriovenous fistulas for hemodialysis. Turkish J Vasc Surg 2007;16:19-24
  3. Brescia MI, Cimino JC, Appel K. Chronic hemodialysis using venipuncture and surgically created arteriovenous fistulas. N Eng J Med 1966;275:1089-92
  4. Guedes Marques M, Ibeas J, Botelho C, Maia P, Ponce P. Doppler ultrasound: a powerful tool for vascular access surveillance. Semin Dial 2015;28:206-210
  5. Wong CS, McNicholas N, Healy D, Clarke-Moloney M, Coffey JC, Grace PA, et al. A systematic review of preoperative duplex ultrasonography and arteriovenous fistula formation. J Vasc Surg 2013;57:1129-33
  6. Ko SH, Bandyk DF, Hodgkiss-Harlow KD, Barleben A, Lane J 3rd. Estimation of brachial artery volume flow by duplex ultrasound imaging predicts dialysis access maturation. J Vasc Surg 2015;61:1521-7
  7. Lomonte C, Meola M, Petrucci I, Casucci F, Basile C. The key role of color Doppler ultrasound in the work-up of hemodialysis vascular access. Semin Dial 2015;28:211-5
  8. Matsui S, Nakai K, Taniguchi T, Nagai T, Yokomatsu T, Kono Y, et al. Systematic evaluation of vascular access by color-Doppler ultrasound decreased the incidence of emergent vascular access intervention therapy and X-ray exposure time: a single-center observational study. Ther Apher Dial 2012;16:169-72
  9. Older RA, Gizienski TA, Wilkowski MJ, Angle JF, Cote DA. Hemodialysis access stenosis: early detection with color DUS. Radiology 1998;207:161-4
  10. Sidawy AN1, Spergel LM, Besarab A, Allon M, Jennings WC, Padberg FT Jr, et al. The Society for Vascular Surgery: clinical practice guidelines for the surgical placement and maintenance of arteriovenous hemodialysis access. J Vasc Surg 2008;48:2S-25S
  11. Bay WH, Henry ML, Lazarus JM, Lew NL, Ling J, Lowrie EG. Predicting hemodialysis access failure with color flow Doppler ultrasound. Am J Nephrol 1998;18:296-304
  12. Dossabhoy NR, Ram SJ, Nassar R, Work J, Eason JM, Paulson WD. Stenosis surveillance of hemodialysis grafts by duplex ultrasound reduces hospitalizations and cost of care. Semin Dial 2005;18:550-7
  13. Schanzer H, Skladany M. Vascular access for dialysis. In: Haimovici H. Editor. Haimovici’s V