Dergiler / Şişli Etfal Hastanesi Tıp Bülteni / 2020 / Cilt: 54 - Sayı: 2

Late Intraluminal Stent Application in Strictures due to Corrosive Esophagitis: Our Preliminary Experiences

Sayfa
176–180
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

All stents had to be removed in mean 38 days because of embedding of the stent, developmentof granulation tissue and intolerance.Conclusion: More research is needed to determine the type, length and diameter of the stent, the timing and the duration of theapplication, the length and level of the stricture suitable for stent application and medications during treatment.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objectives: Household chemicals result in corrosive esophageal burns in the developing third world countries, and most of themcause esophageal strictures.
📊
Temel Bulgular & Veri:Here, we present our preliminary experiencewith intraluminal esophageal stents for stricture treatment.Methods: The files of the patients who had stenosis due to corrosive esophagitis in our clinic were evaluated retrospectively.Stricture lengths were between 30 and 130 mm.
💡
Sonuç & Katkı:All stents had to be removed in mean 38 days because of embedding of the stent, developmentof granulation tissue and intolerance.Conclusion: More research is needed to determine the type, length and diameter of the stent, the timing and the duration of theapplication, the length and level of the stricture suitable for stent application and medications during treatment.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

Objectives: Household chemicals result in corrosive esophageal burns in the developing third world countries, and most of themcause esophageal strictures. There is no standard treatment for esophageal strictures. Here, we present our preliminary experiencewith intraluminal esophageal stents for stricture treatment.Methods: The files of the patients who had stenosis due to corrosive esophagitis in our clinic were evaluated retrospectively.Stricture lengths were between 30 and 130 mm. Stents were self-expandable, made of nitinol alloy that was covered with silicone,and they were cylindrical in shape with a conical tip. The lengths varied between 60 and 170 mm and the diameters were between10-20 mm. The stent application was made under general anaesthesia.Results: There were seven patients (four girls and three boys). After stent application, all patients experienced constant or temporarypain, vomiting, and difficulty in swallowing. Bleeding occurred in one patient. Sudden death occurred in one patient, probablyas a complication of chest infection. All stents had to be removed in mean 38 days because of embedding of the stent, developmentof granulation tissue and intolerance.Conclusion: More research is needed to determine the type, length and diameter of the stent, the timing and the duration of theapplication, the length and level of the stricture suitable for stent application and medications during treatment.

🔖

Bu Makaleye Atıf Yap

KABA, M., KARADAĞ, Ç. A., DEMİR, M., SEVER, N., AKIN, M., DOKUCU, A. İ. (2020). Late Intraluminal Stent Application in Strictures due to Corrosive Esophagitis: Our Preliminary Experiences. Şişli Etfal Hastanesi Tıp Bülteni, Cilt: 54 - Sayı: 2, 176–180. https://ajindex.com/articles/363407

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (11)

  1. Spitz L. Esophageal Replacement. In: Grosfeld J, O’Neill, Coran A Fonkalsrud E. Pediatric Surgery. 6th ed. Philadelphia: Mosby Elsevier; 2006. p. 1093–106
  2. Lee SH. The role of oesophageal stenting in the non-surgical management of oesophageal strictures. Br J Radiol. 2001;74(886):891– 900
  3. Zhang C, Yu JM, Fan GP, Shi CR, Yu SY, Wang HP, Ge L, Zhong WX. The use of a retrievable self-expanding stent in treating childhood benign esophageal strictures. J Pediatr Surg 2005;40:501–4
  4. Cheng YS, Li MH, Chen WX, Zhuang QX, Chen NW, Shang KZ. Follow- up evaluation for benign stricture of upper gastrointestinal tract with stent insertion. World J Gastroenterol 2003;9:2609–11
  5. Maetani I, Ukita T, Inone H, Yoshida M, Igarashi Y, Sakai Y. Knittednitinol stent insertion for various intestinal stenoses with a modified delivery system. Gastrointest Endosc 2001;54:364–7
  6. Reyes HM, Hill JL. Modification of the experimental stent technique for esophageal burns. J Surg Res 1976;20:65–70
  7. Peppo FD, Rivosecchi M, Federici G, Matarazzo E, Ponticelli A, Schingo P, et al. Conservative treatment of corrosive esophageal strictures: A comparative study of endoscopic dilatations and esophageal stenting. Pediatr Surg Int 1993;8:2–7
  8. Shin JH, Song HY, Ko GY, Shim TS, Kim SW, Cho YK, et al. Treatment of tracheobronchial obstruction with a polytetrafluoroethylenecovered retrievable expandable nitinol stent. J Vasc Interv Radiol 2006;17:657–63
  9. Cwikiel W, Willén R, Stridbeck H, Lillo-Gil R, von Holstein CS. Selfexpanding stent in the treatment of benign esophageal strictures: experimental study in pigs and presentation of clinical cases. Radiology 1993;187:667–71
  10. Mutaf O. Treatment of corrosive esophageal strictures by longterm stenting. J Pediatr Surg 1996;31:681–5
  11. Millar AJW, Numanoglu A, Rode H. Caustic strictures of the esophagus. In: Grosfeld JL,O’Neill JA, Fonkalsrud EW, Coran AG, editors. Pediatric Surgery. 6th ed. Philadelphia: Mosby Elsevier; 2006. p. 1082–92.