Dergiler / The European Research Journal / 2017 / Cilt: 3 - Sayı: 2

Biometric and intraocular pressure changes after Nd:YAG laser capsulotomy

Sayfa
140–144
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The BCVA and ACD values follow-up period should be at least one month after Nd:YAG capsulotomy.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:We aimed to investigate the influences of Nd:YAG (neodymium-doped yttrium aluminum garnet) laser capsulotomy on ocular biometric parameters.
📊
Temel Bulgular & Veri:In this prospective study, 117 eyes of 117 pseudophakic patients were included.
💡
Sonuç & Katkı:The BCVA and ACD values follow-up period should be at least one month after Nd:YAG capsulotomy.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Ocular biometry · Nd:YAG laser capsulotomy · LenStar

Abstract

Objective. We aimed to investigate the influences of Nd:YAG (neodymium-doped yttrium aluminum garnet) laser capsulotomy on ocular biometric parameters. Methods. In this prospective study, 117 eyes of 117 pseudophakic patients were included. Full ocular examination, the best-corrected visual acuity (BCVA), and intraocular pressure (IOP) measurements were performed before the procedure as well as one week, one month, and three months after Nd:YAG laser capsulotomy. The axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), and pupil diameter (PD) were measured by LenStar 900 optical biometry. The measurements were repeated one week, one month, and three months. Results. The BCVA improvements at preoperative, one week, and one month were statistically significant, but no significant changes in the BCVA were found at one month and three months (p=0.345). No association was found between the capsulotomy and mean IOP changes during the follow-up period (p=0.300). No significant changes were found in the CCT (p=0.059). The ACD changes occurred at preoperative; the first week and the first month were statistically significant (p<0.001). No statistically significant differences were found between the first month and the third month (p=0.365). No significant changes in the pupil size (p=0.200) and AL (p=0.112) were found after Nd:YAG laser capsulotomy. Conclusıons. Our study demonstrated that the BCVA parameter changed after Nd:YAG laser capsulotomy. The BCVA and ACD values follow-up period should be at least one month after Nd:YAG capsulotomy.

🔖

Bu Makaleye Atıf Yap

ŞİMŞEK, A. (2017). Biometric and intraocular pressure changes after Nd:YAG laser capsulotomy. The European Research Journal, Cilt: 3 - Sayı: 2, 140–144. https://ajindex.com/articles/361364

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Bai L, Zhang J, Chen L, Ma T, Liang HC. Comparison of posterior capsule opacification at 360-degree square edge hydrophilic and sharp edge hydrophobic acrylic intraocular lens in diabetic patients. Int J Ophthalmol 2015;8:725-9
  2. Cetinkaya S, Cetinkaya YF, Yener HI, Dadaci Z, Ozcimen M, Acir NO. The influence of size and shape of Nd:YAG capsulotomy on visual acuity and refraction. Arq Bras Oftalmol 2015;78:220-3
  3. Cobo LM, Ohsawa E, Chandler D, Arguello R, George G. Pathogenesis of capsular opacification after extracapsular cataract extraction. An animal model. Ophthalmology 1984;91:857-63
  4. Aron-Rosa D, Aron JJ, Griesemann M, Thyzel R. Use of the neodymium-YAG laser to open the posterior capsule after lens implant surgery: a preliminary report. J Am Intraocul Implant Soc 1980;6:352-4
  5. Shaikh A, Shaikh F, Adwani JM, Shaikh ZA. Prevalence of different Nd: YAG Laser induced complication in patients with significant posterior capsule opacification and their correlation with time duration after standard cataract surgery. Int J Med Med Sci 2010;2:12-7
  6. Yilmaz T, Yilmaz A. Long-term changes in subfoveal choroidal thickness and central macula thickness after Nd:YAG lasercapsulotomy. Int Ophthalmol 2016 Oct 3
  7. Sherrard ES, Kerr Muir MG. Damage to corneal endothelium by Q switched Nd: YAG laser posterior capsulotomy. Trans Ophthalmol Soc UK 1985;104(Pt5):524-8
  8. Wilkins M, Mcpherson R, Fergusson V. Visual recovery under glare conditions following laser capsulotomy. Eye 1996;10(Pt1):117-20
  9. Burq MA, Taqui AM. Frequency of retinal detachment and other complications after Neodymium: YAG laser capsulotomy. J Pak Med Assoc 2008;58:550-2
  10. Khambhiphant B, Liumsirijarern C, Saehout P. The effect of Nd:YAG laser treatment of posterior capsule opacification on anterior chamber depth and refraction in pseudophakic eyes. Clin Ophthalmol 2015;9:557-61
  11. Pandey SK, Apple DJ, Werner L, Maloof AJ, Milverton EJ. Posterior capsule opacification: a review of the aetiopathogenesis, experimental and clinical studies and factors for prevention. Indian J Ophthalmol 2004;52:99-112
  12. Chambless WS. Neodymium: YAG laser posterior capsulotomy results and complications. J Am Intraocul Implant Soc 1985;11:31-2
  13. Buckhurst PJ, Wolffsohn JS, Shah S, Naroo SA, Davies LN, Berrow EJ. A new optical low coherence reflectometry device for ocular biometry in cataract patients. Br J Ophthalmol 2009;93:949-53
  14. Oztas Z, Palamar M, Afrashi F, Yagci A. Th