Dergiler / The European Research Journal / 2019 / Cilt: 5 - Sayı: 3

Physio-chemical investigation and analyses of contaminants in groundwater flow. Case study - Papalanto, Ifo local government area, South - Western Nigeria, Ogun State

Sayfa
440–448
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Hence, the groundwater near the leachate is confirmed contaminated.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objectives: Groundwater is the primary source of drinking water for roughly, a third of the world’s population, but highly vulnerable to pollution.
📊
Temel Bulgular & Veri:Other physical parameters like color, turbidity, conductivity, total suspended solids, total dissolved solid, total hardness, total alkalinity, total acidity, calcium, magnesium, chloride, nitrite, manganese, lead, nickel, nitrate, have higher values than the authorized standard value, which directly or indirectly affect the water content found in the area for drinking purpose.
💡
Sonuç & Katkı:Hence, the groundwater near the leachate is confirmed contaminated.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Groundwater · contaminants · well

Abstract

Objectives: Groundwater is the primary source of drinking water for roughly, a third of the world’s population, but highly vulnerable to pollution. A thorough research was carried out to investigate the extent of groundwater contamination on four active dumpsite and a control point at Papalanto, Abeokuta area, and South-Western Nigeria. Methods: Domestic wells in the area facilitated the resources for water chemistry. A total of five groundwater samples were collected from wells located close to different dumpsite in the study area, to determine the extent of groundwater contamination. Physio-chemical analysis was carried out on the five water samples; the basic method adopted in the chemical analysis includes titrimetric method, atomic absorption spectroscopy and calometric method. Results: The results showed that water quality parameter like temperature, pH, taste, odour, total solids, sulphate, copper, iron, zinc, cadmium and chromium are in appropriate standard prescribed by WHO and NSDWQ. Other physical parameters like color, turbidity, conductivity, total suspended solids, total dissolved solid, total hardness, total alkalinity, total acidity, calcium, magnesium, chloride, nitrite, manganese, lead, nickel, nitrate, have higher values than the authorized standard value, which directly or indirectly affect the water content found in the area for drinking purpose. These features could be attributed to the possible activities of contaminants facilitated by leachate plume from the dumpsite. Conclusions: The study shows that the regolith aquifer in the area of study is highly vulnerable to pollution from the refuse dumps. From the geophysical and physio-chemical analysis carried out, the values of most parameters obtained in the water samples collected at locations close to the leachate have been confirmed to be higher than those collected at locations away from the leachate. Hence, the groundwater near the leachate is confirmed contaminated.

🔖

Bu Makaleye Atıf Yap

OLORODE, O. D., ADENEYE, S. O., MORAKİNYO, A. D., OYENEYİN, O. A., AKPOCHAFOR, M. O., OMOJOLA, A. D. (2019). Physio-chemical investigation and analyses of contaminants in groundwater flow. Case study - Papalanto, Ifo local government area, South - Western Nigeria, Ogun State. The European Research Journal, Cilt: 5 - Sayı: 3, 440–448. https://ajindex.com/articles/361020

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (15)

  1. Brand EC. Hazardous waste management in the European Community. Implications of ‘1992’ Sci Total Environ 1993;129:241-51
  2. Cooke RU, Doornkamp JC. Geomorphology in Environmental Management: An Introduction. Oxford: University Press. 1st Ed. edition (October 24, 1974) Available at:
  3. Vijaya Sankar M, Abideen S, Babu Selvam M, Gunasekaran T, Hussain Syed Bava M. A comparative study of ground water by physiochemical parameter and water quality in the Lalgudi taluk of angari pancyayat of Tiruchirappalli district in Tamilnadu, India. Int J Sci Environ Technol 2014;3:348-56
  4. Oyelami AC, Ojo AO, Aladejana JA, Agbede OO. Assessing the effect of a dumpsite on groundwater quality: a case study of Aduramigba Estate within Osogbo Metropolis. J Environ Earth Sci 2013;3:120-30
  5. Vodela JK, Renden JA, Lenz SD, McElhenney WH, Kemppainen BW. Drinking water contaminants (arsenic, cadmium, lead, benzene, and trichloroethylene)
  6. Interaction of contaminants with nutritional status on general performance and immune function in broiler chickens. Poult Sci 1997;76:1474-92
  7. Mendie U. The Nature of Water. In: The Theory and Practice of Clean Water Production for Domestic and Industrial Use Lagos: Lacto-Medals publishers, 2005:pp.1-21
  8. Ikem A, Osibanjo O, Sridhar MKC, Sobande A. Evaluation of groundwater quality characteristics near two waste sites in Ibadan and Lagos, Nigeria. Water Air Soil Poll 2002;140:307-33
  9. Ushie F, Harry T, Affiah U. Reserve estimation from geoelectrical sounding of the Ewekoro Limestone at Papalanto, Ogun State, Nigeria. J Energy Technol Policy 2014;4:28-32
  10. Jones HA, Hockey RD. The geology of parts of South-Western Nigeria. Geol Surv Nig Bull 1964;31:101
  11. Owulakoda Blog. Authority Site of Owu People of the Yoruba Tribe, Nigeria. 2010
  12. Ogbe FGA. Stratigraphy of strata exposed in the Ewekoro Quarry, SW Nigeria, in: Dessauvagie TFJ, Whiteman (eds.), African Geology, Press, Nigeria. 1972:pp. 305
  13. Gbadebo AM, Amos AJ. Assessment of radionuclide pollutants in Bedrocks and soils from Ewekoro cement factory, Southwestern Nigeria. Asian J Appl Sci 2010;3:135-44
  14. Alile OM, Oranusi S, Adetola OO, Airen JO. Subsurface geophysical investigation and physiochemical/microbial contaminant in Ota, Southwestern Nigeria. Geosciences 2012;2:179-84
  15. Water conductivity, 2013, Lenntech- http://www.lenntech.com/applications/ultrapure/conductivity/