Dergiler / Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi / 2020 / Cilt: 11 - Sayı: 2

Verification Of Percentage Depth-Doses With Monte Carlo Simulation and Calculation Of Mass Attenuation Coefficients For Various Patient Tissues In Radiation Therapy

Verification of Percentage Depth-Doses with Monte Carlo Simulation and Calculation of Mass Attenuation Coefficients for Various Patient Tissues in Radiation Therapy

Sayfa
224–230
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Bulgular: Geant4 modellemesinin sonuçları, yüzde derin doz eğrileri için deneysel ölçümlerle uyumlu bulundu.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Amaç: Bu çalışmanın ilk kısmında, 6 MV ve 18 MV x-ışını foton demeti için deneysel olarak elde edilen yüzde derin doz eğrilerinin, Geant4 Monte Carlo simülasyonu kullanılarak doğrulanması amaçlanmıştır.
📊
Temel Bulgular & Veri:Materyal-Metot: Varian Clinac IX lineer hızlandırıcı cihazında deneysel olarak ölçülen merkezi eksen yüzde derin dozları; 6 MV ve 18 MV x- ışını foton enerjileri için 10x10 cm2 ve 30x30 cm2 alan boyutlarında, Monte Carlo simülasyonu (Geant4) ile hesap edilerek doğrulandı.
💡
Sonuç & Katkı:Bulgular: Geant4 modellemesinin sonuçları, yüzde derin doz eğrileri için deneysel ölçümlerle uyumlu bulundu.
🔬Tür:Deneysel Tarla Denemesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Radyoterapi · Geant4 · MATLAB

Özet

Amaç: Bu çalışmanın ilk kısmında, 6 MV ve 18 MV x-ışını foton demeti için deneysel olarak elde edilen yüzde derin doz eğrilerinin, Geant4 Monte Carlo simülasyonu kullanılarak doğrulanması amaçlanmıştır. Buna ek olarak; çalışmanın ikinci kısmında, MATLAB ve XCOM programları kullanılarak, çeşitli insan dokularının ve suyun kütle zayıflatma katsayıları hesap edilerek karşılaştırıldı. Materyal-Metot: Varian Clinac IX lineer hızlandırıcı cihazında deneysel olarak ölçülen merkezi eksen yüzde derin dozları; 6 MV ve 18 MV x- ışını foton enerjileri için 10x10 cm2 ve 30x30 cm2 alan boyutlarında, Monte Carlo simülasyonu (Geant4) ile hesap edilerek doğrulandı. Ek olarak; kan, kemik, yağ dokusu, kas, deri ve suyun kütle zayıflama katsayıları MATLAB ile hesaplanarak, NIST XCOM verileri ile karşılaştırıldı. Bulgular: Geant4 modellemesinin sonuçları, yüzde derin doz eğrileri için deneysel ölçümlerle uyumlu bulundu. Geant4' ün; deneysel sonuçlar ile tutarlılığı, 10x10 cm2 alan büyüklüğünde 6 MV foton enerjisi için daha belirgindi. MATLAB ve XCOM sonuçları arasında; bahsi geçen tüm insan dokuları için kemik hariç hiçbirinde istatistiksel olarak anlamlı bir fark bulunmadı (her iki cinsiyette kemik için p=0.039). En düşük medyan yüzde farkı, su ve cilt için sırasıyla 1.23% ve 2.19% olarak hesaplandı. Sonuç: Geant4, tıbbi linaklarda, yüzde derin doz eğrilerini hesaplamak için kullanılabilir. MATLAB ile hesaplanan kütle zayıflatma katsayıları önceki çalışmalarda diğer yazılım programları ile elde edilen sonuçlarla tutarlı bulundu. Bu da, MATLAB'ın çeşitli insan dokularının yanı sıra suyun kütle zayıflama katsayılarını hesap etmek için alternatif bir simülasyon aracı olarak kullanılabileceğini göstermektedir.

Abstract

Objective: First part of this work dedicated to the verification of the percentage depth dose curves that obtained experimentally for 6 MV and 18 MV x-ray photon beams via using Geant4 Monte Carlo simulation. Second part of this study compared the computed mass attenuation coefficients of various human tissues and water between MATLAB and XCOM. Material-Methods: The central-axis percentage depth doses of Varian Clinac IX linear accelerator were verified via Monte Carlo simulation (Geant4) with square field sizes (10x10 and 30x30 cm2) for 6 MV and 18 MV x-ray photon energies. In addition, mass attenuation coefficients of adipose tissue, blood, muscle, bone, skin and water were computed with MATLAB and were compared with the NIST XCOM data. Results: Results of the Geant4 modeling were in line with the experimental measurements for percentage depth dose curves. The consistency of Geant4 with experimental results was more explicit for 6 MV photons with the field size of 10x10 cm2. No statistical significant difference between MATLAB and XCOM were found for all mentioned human tissues, except for bone (p=0.039 for bone in both genders). The minimum median percentage difference were calculated for water and skin with a result of 1.23% and 2.19%, respectively. Conclusion: Geant4 can be used to predict percentage depth dose curves for medical linacs. Mass attenuation coefficients calculated with MATLAB yielded consistent results with previous studies, which means MATLAB can be used as an alternative simulation tool for estimating mass attenuation coefficients of various human tissues and water.

🔖

Bu Makaleye Atıf Yap

ÖZSEVEN, A., KARA, Ü. (2020). Verification Of Percentage Depth-Doses With Monte Carlo Simulation and Calculation Of Mass Attenuation Coefficients For Various Patient Tissues In Radiation Therapy. Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi, Cilt: 11 - Sayı: 2, 224–230. https://ajindex.com/articles/360267

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Gottfried KLD, Penn G, editors. Institute of Medicine (US) Committee for Review and Evaluation of the Medical Use Program of the Nuclear Regulatory Commission; Radiation In Medicine: A need for regulatory reform. Washington (DC): National Academies Press (US); 1996. Available from:
  2. Caccia B, Andenna C, Cirrone GA. MedLinac2: a GEANT4 based software package for radiotherapy. Ann Ist Super Sanita. 2010; 46(2): 173-177. DOI: 10.4415/ANN_10_02_11
  3. Stewart BW, Wild CP, editors. World cancer report 2014. Lyon: International Agency for Research on Cancer; 2014
  4. Xu XG, Bednarz B, Paganetti H. A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction phases. Phys in Med Biol. 2008; 53: R193-R241
  5. Agostinelli S., Allison J., Amako K., Apostolaki J., Araujo H., Arce P, et al. Geant4 – a simulation toolkit. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2003; 56 (3): 250-303
  6. El Bakkali J and El Bardouni T. Validation of Monte Carlo Geant4 code for a 6 MV varian linac. J. King Saud Univ. Sci. 2017; 29: 106–113
  7. Carrier JF, Archambault L, Beaulieu L. Validation of GEANT4 (an object-oriented Monte Carlo toolkit) for simulations in medical physics. Med Phys. 2004; 31: 484-492
  8. Kienböch R. On the quantimetric method. Arch Roentgen Ray. 1906; 11: 17
  9. Tekin HO, Singh VP, Altunsoy EE, Manici T, Sayyed M. Mass attenuation coefficients of human body organs using MCNPX Monte Carlo code. Iran J Med Phys. 2017; 14: 229-240. DOI:10.22038/ijmp.2017.23478.1230
  10. Jones AK, Hintenlang DE and Bolch WE. Tissue-equivalent materials for construction of tomographic dosimetry phamtons in pediatric radiology. Med. Phys. 2003; 30: 2072-2081
  11. ICRU. Tissue substitutes in radiation dosimetry and measurement ICRU Report 44. Bethesda, MD, USA: International Commission on Radiation Units and Measurements; 1989
  12. ICRP. Basic Anatomical and physiological data for use in radiological protection: Reference Values: ICRP Publication 89. Ann. ICRP 32 (3-4). Pergamon; 2002
  13. Hubbell JH. Review and history of photon cross section calculations. Phys. Med. Biol. 2006; 51: 245-262
  14. Foppiano F, Mascialino B, Pia MG, Piergentili M (2004) A Geant4 based simulation of an accelerator head for intensity modulated radiation therapy. In: Nuclear Science Symposium Conference Record, IEEE. 2004; 4: 2128–