Dergiler / Atmospheric Pollution Research / 2018 / Cilt: 9 - Sayı: 4

Multi-elemental analysis of particulate matter samples collected by a particle-into-liquid sampler

Sayfa
747–754
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Similarly, increases in the concentration of these elements were also observedin the outdoor environment during spot events of agricultural waste combustion, an illegal activityfrequently practiced in many rural areas.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Time-resolved elemental analysis of particulate matter (PM) helps in the reliable identification of specific sourcetracers and study of mixing dynamics in the lower atmosphere.
📊
Temel Bulgular & Veri:Through this system, the limits of detection and quantification were significantly reduced, comparedto those of ICP-MS analysis of samples collected by a PILS after off-line filtration.
💡
Sonuç & Katkı:Similarly, increases in the concentration of these elements were also observedin the outdoor environment during spot events of agricultural waste combustion, an illegal activityfrequently practiced in many rural areas.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

Time-resolved elemental analysis of particulate matter (PM) helps in the reliable identification of specific sourcetracers and study of mixing dynamics in the lower atmosphere. In this study, a new flow system (FS) for theintroduction of samples into the inductively coupled plasma mass spectrometry (ICP-MS) instrument, whichconsists of on-line filtration and acidification of samples collected by a particle-into-liquid sampler (PILS), wasoptimised. Through this system, the limits of detection and quantification were significantly reduced, comparedto those of ICP-MS analysis of samples collected by a PILS after off-line filtration. This makes it possible toconduct multi-elemental analysis of the samples collected by the PILS without any pre-treatment. The optimisedFS-ICP-MS system was directly coupled with a PILS in order to study the profiles of some selected indoor andoutdoor sources of PM (cigarette smoking, incense burning, brushwood burning, pellet burning, and road dustresuspension). The application of the FS-ICP-MS system for off-line elemental analysis of samples collected by aPILS during spot events in indoor and outdoor environments allowed us to verify the suitability of this system forthe time-resolved (10 min) analysis of PM. The results indicate a significant increase in the indoor concentrationsof some toxic elements (such as, Cd, and Pb) during the cleaning operation of domestic biomass burning systems(pellet stoves and thermo-fireplaces). Similarly, increases in the concentration of these elements were also observedin the outdoor environment during spot events of agricultural waste combustion, an illegal activityfrequently practiced in many rural areas.

🔖

Bu Makaleye Atıf Yap

SİMONETTİ, G., FRASCA, D., MARCOCCİA, M., FARAO, C., CANEPARİ, S. (2018). Multi-elemental analysis of particulate matter samples collected by a particle-into-liquid sampler. Atmospheric Pollution Research, Cilt: 9 - Sayı: 4, 747–754. https://ajindex.com/articles/351488

Kaynakça (6)

  1. Barnaba, F., Bolignano, A., Di Liberto, L., Morelli, M., Lucarelli, F., Nava, S., Perrino, C., Canepari, S., Basart, S., Costabile, F., Ciampichetti, S., Sozzi, R., Gobbi, G.P., Dionisi, D., 2017. Desert dust contribution to PM10 loads in Italy: methods and recommendations addressing the relevant european commission guidelines in support to the air quality directive 2008/50. Atmos. Environ. 161, 288–305.
  2. Bogenschütz, G., Emmenegger, C., and Kalcher, M.: Semicontinuous determination of anions, cations, and heavy metals in aerosols using PILS-IC-VA G technical report: http://www.metrohm.com/com/Applications (search for 8.000.6086EN). Bukowiecki, N., Hill, M., Gehrig, R., Zwicky, C.N., Lienemann, P., Hegedus, F., Falkenberg, G., Weingartner, E., Baltensperger, U., 2005. Trace metals in ambient air: hourly size-segregated mass concentrations determined by synchrotron-XRF. Environ. Sci. Technol. 39, 5754–5762. http://dx.doi.org/10.1021/es048089m.
  3. Canepari, S., Perrino, C., Olivieri, F., Astolfi, M.L., 2008. Characterisation of the traffic sources of PM through size-segregated sampling, sequential leaching and ICP analysis. Atmos. Environ. 42, 8161–8175. http://dx.doi.org/10.1016/j.atmosenv.2008. 07.052. Canepari, S., Pietrodangelo, A., Perrino, C., Astolfi, M.L., Marzo, M.L., 2009. Enhancement of source traceability of atmospheric PM by elemental chemical fractionation. Atmos. Environ. 43, 4754–4765. http://dx.doi.org/10.1016/j.atmosenv. 2008.09.059. Canepari, S., Astolfi, M.L., Moretti, S., Curini, R., 2010. Comparison of extracting solutions for elemental fractionation in airborne particulate matter. Talanta 82, 834–844. http://dx.doi.org/10.1016/j.talanta.2010.05.068.
  4. Canepari, S., Astolfi, M.L., Farao, C., Maretto, M., Frasca, D., Marcoccia, M., Perrino, C., 2014. Seasonal Variations in the chemical composition of particulate matter: a case study in the Po Valley. Part II: concentration and solubility of micro- and trace-elements. Environ. Sci. Pollut. Res. 21, 4010–4022. http://dx.doi.org/10.1007/s11356- 013-2298-1.
  5. Furger, M., Minguillón, M.C., Yadav, V., Slowik, J.G., Hüglin, C., Fröhlich, R., Petterson, K., Baltensperger, U., Prévôt, A.S., 2017. Elemental composition of ambient aerosols measured with high temporal resolution using an online XRF spectrometer. Atmos. Meas. Technol. 10 (6), 2061.
  6. Gotschi, T., Hazenkamp-von Arx, M., Heinrich, J., Bono, R., Burney, P., Forsberg, B., Jarvis, D., Maldonado, J., Norback, D., Stern, W., Sunyer, J., Toren, K., Ve