This observation underlines the importance of the operational units when designing a PV power plant.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:In photovoltaic (PV) systems, power generation is significantly affected by partial or complete shading of solar panels.
📊
Temel Bulgular & Veri:In this study, the effects of shading caused by a transformer building on the performance of a PV array in an on-grid solar power plant were investigated under real operating conditions.
💡
Sonuç & Katkı:This observation underlines the importance of the operational units when designing a PV power plant.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Partial shading · Sustainability · Photovoltaics

Özet

In photovoltaic (PV) systems, power generation is significantly affected by partial or complete shading of solar panels. In this study, the effects of shading caused by a transformer building on the performance of a PV array in an on-grid solar power plant were investigated under real operating conditions. The performaces onf the shaded and the unshaded array were regularly observed under the outdoor climatic conditions on clear and sunny days for 12 months. As a result of the evaluation of performance data, the total power loss due to the transformer building was calculated to be 307 kW (0.66%) in the shaded 30 kW-PV array after one-year operation of the power plant. It is obvious that the energy loss caused by the shading effect will reach up to power in MW scale when considered since photovoltaic energy systems have lifetime up to 30 years. This observation underlines the importance of the operational units when designing a PV power plant.

Abstract

In photovoltaic (PV) systems, power generation is significantly affected by partial or complete shading of solar panels. In this study, the effects of shading caused by a transformer building on the performance of a PV array in an on-grid solar power plant were investigated under real operating conditions. The performaces onf the shaded and the unshaded array were regularly observed under the outdoor climatic conditions on clear and sunny days for 12 months. As a result of the evaluation of performance data, the total power loss due to the transformer building was calculated to be 307 kW (0.66%) in the shaded 30 kW-PV array after one-year operation of the power plant. It is obvious that the energy loss caused by the shading effect will reach up to power in MW scale when considered since photovoltaic energy systems have lifetime up to 30 years. This observation underlines the importance of the operational units when designing a PV power plant.

🔖

Bu Makaleye Atıf Yap

KESKİN, V., KHALEJAN, S. H. P. R., ÇIKLA, R. (2021). Investigation of the Shading Effect on the Performance of a grid-connected PV Plant in Samsun/Turkey. Politeknik Dergisi, Cilt: 24 - Sayı: 2, 553–563. https://ajindex.com/articles/306239

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. Ramli, M.Z., Salam, Z. (2019). Performance evaluation of dc power optimizer (DCPO) for photovoltaic (PV) system during partial shading. Renewable Energy, 139:1336-1354
  2. Hachicha, A.A., Al-Sawafta, I., Said, Z. (2019). Impact of dust on the performance of solar photovoltaic (PV) systems under United Arab Emirates weather conditions. Renewable Energy, 141:287-297
  3. Dolara, A., Lazaroiu, G.C., Leva, S., Manzolini, G. (2013). Experimental investigation of partial shading scenarios on PV (photovoltaic) modules. Energy, 55:466-475
  4. Maftah, A., Maarouft, M. (2019). Experimental evaluation of temperature effect of two different PV Systems Performances under arid climate. Energy Procedia, 157: 701-708
  5. Mert, B.D., Ekinci, F., Demirdelen, T. (2019). Effect of partial shading conditions on off-grid solar PV/Hydrogen production in high solar energy index regions. International Journal of Hydrogen Energy, 44:277, 13-25
  6. Winston, D.P., Kumaravel, S., Kumar, B.P., Devakirubakaran, S. (2020). Performance improvement of solar PV array topologies during various partial shading conditions. Solar Energy, 196:228-242
  7. Pendem, S.R., Mikkili, S. (2018). Modeling, simulation and performance analysis of solar PV array configurations (Series, Series–Parallel and Honey-Comb) to extract maximum power under Partial Shading Conditions. Energy Reports, 4:274-287
  8. Ma, M., Liu, H., Zhang, Z., Yun, P., Liu, F. (2019). Rapid diagnosis of hot spot failure of crystalline silicon PV module based on I-V curve. Microelectronics Reliability, 100-101, [9] Guerriero, P., Tricoli, P., Daliento, S. (2019). A bypass circuit for avoiding the hot spot in PV Modules. Solar Energy, 181:430-438
  9. Hanifi, H., Pander, M., Jaeckel, B., Schneider, J., Bakhtiari, A., Maier, W. (2019). A novel electrical approach to protect PV modules under various partial shading situations. Solar Energy, 193:814-819
  10. Krishna, G.S., Moger, T. (2019). Reconfiguration strategies for reducing partial shading effects in photovoltaic arrays: State of the art. Solar Energy, 182:429-452.,[12] Ryad, A.K., Atallah, A.M., Zekry, A. (2019). Photovoltaic Array Reconfiguration under Partial Shading Based on Integer Link Matrix and Harmony Search. European Journal of Electrical Engineering, 21:471-477
  11. Silvestre, S., Boronat, A., Chouder, A. (2009). Study of bypass diodes configuration on PV modules. Applied Energy, 86(9):16, 32-40
  12. Daliento, S., Napoli, F.D., Guerriero, P., d’Alessandro, V.