Dergiler / Research on Engineering Structures and Materials / 2018 / Cilt: 4 - Sayı: 1

The required ductility reduction of soft storey buildings through application of base isolation

Sayfa
49–60
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

This means that the base isolation technique is a good alternative to be applied in buildings with first soft/weak storey structure.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The Response Spectrum Analysis of the structures is based on the allowable ductility considered for that structure.
📊
Temel Bulgular & Veri:Linear Response Spectrum analysis and Nonlinear Time History analysis are performed in order to determine the required storey ductility for the existing and new soft/weak storey buildings using the SAP2000 computer program.
💡
Sonuç & Katkı:This means that the base isolation technique is a good alternative to be applied in buildings with first soft/weak storey structure.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

The Response Spectrum Analysis of the structures is based on the allowable ductility considered for that structure. In the case of multi-degree-of-freedom buildings, the required ductility cannot be the same with the allowable ductility; furthermore, the required ductility values are different for different storey. In the case of first soft/weak storey building, the required ductility of this storey is much higher compared to allowable ductility and impossible to achieve. Nowadays there are many cases of existing reinforced concrete structures with the possibility of soft/weak storey. Even new structures are required to have open space at ground floor level as the owners want them for shops or garages usage. This paper analysis the influence of base isolation to the required storey ductility of weak storey buildings. A five storey shear frame type structure is considered as the model. The elastic and elasto-plastic modeling of the structural elements and bilinear modeling of rubber isolators are used. Linear Response Spectrum analysis and Nonlinear Time History analysis are performed in order to determine the required storey ductility for the existing and new soft/weak storey buildings using the SAP2000 computer program. The analysis results show the reduction of the required storey ductility due to the application of base isolation not only in new structures, but in existing structures too. This means that the base isolation technique is a good alternative to be applied in buildings with first soft/weak storey structure.

🔖

Bu Makaleye Atıf Yap

SERANAJ, A., GAREVSKİ, M. (2018). The required ductility reduction of soft storey buildings through application of base isolation. Research on Engineering Structures and Materials, Cilt: 4 - Sayı: 1, 49–60. https://ajindex.com/articles/302666

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (5)

  1. Chopra AK. Dynamics of Structures: Theory and Application to Earthquake Engineering. 2nd Ed, Pearson Prentice Hall, Upper Saddle River, New Jersey, 2007.
  2. Skinner RI, Robinson WH, McVerry GH. An Introduction to Seismic Isolation. John Wiley & Sons Ltd., New York, 1993.
  3. Naeim F, Kelly JM. Design of Seismic Isolated Structures. John Wiley & Sons, New York, 1999.https://doi.org/10.1002/9780470172742
  4. Higashino M, Okamoto S. Response Control and Seismic Isolation of Buildings. Taylor & Francis, New York, 2006. KellyJM. Earthquake Resistant Design with Rubber. Springer-Verlag London Limited, 1997.https://doi.org/10.1007/978-1-4471-0971-6 Kelly E Trevor. Base Isolation of Structures, Holmes, Consulting Group Ltd, 2001. SAP2000®, Integrated Finite Element Analysis and Design of Structures, analysis Reference, Vol. 1&2, Computer and Structures, Inc, Berkeley, California, USA, 2000 Seranaj A. Dynamic Response and Seismic Analysis of Base Isolated Buildings. Monograph, Scholar's Press, www.omniscriptum.com, Germany, 2016. Seranaj A. ReagimiDinamikdheAnalizaSizmike e StrukturavetëIzoluaranëBazë me IzolatorGome me Fibra.DisertacionDoktorature, Tiranë, Albania, 2015
  5. Kelly JM, Quiroz E. Mechanical Characteristics of Neoprene Isolation Bearings. UCB/EERC–92/11, 1992.