Dergiler / Research on Engineering Structures and Materials / 2018 / Cilt: 4 - Sayı: 3

Darrieus vertical axis wind turbines: methodology to study the self-start capabilities considering symmetric and asymmetric airfoils

Sayfa
189–217
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Both symmetrical and asymmetrical airfoils are targeted in our study, presenting comprehensive results to validate our methodology

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The rapid growth of wind power generation and the need for a smarter grid with decentralized energy generation has increased the interest in vertical axis wind turbines (VAWT), especially for the urban areas.
📊
Temel Bulgular & Veri:The existing methodologies are usually used to optimize the wind turbine performance, but not its ability to self-start.
💡
Sonuç & Katkı:Both symmetrical and asymmetrical airfoils are targeted in our study, presenting comprehensive results to validate our methodology
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

The rapid growth of wind power generation and the need for a smarter grid with decentralized energy generation has increased the interest in vertical axis wind turbines (VAWT), especially for the urban areas. For the urban areas the VAWT offer several advantages over the horizontal ones, so their acceptance is rising. The lift-type VAWT (Darrieus wind turbines) have a natural inability to self-start without the help of extra components. The existing methodologies are usually used to optimize the wind turbine performance, but not its ability to self-start. Indeed, studying the aerodynamic behavior of blade profiles is a very complex and time-consuming task, since blades move around the rotor axis in a threedimensional aerodynamic environment. Hence, a new methodology is presented in this paper to study the self-start ability of VAWT, which offers a substantial time reduction in the first steps of new blade profiles development. Both symmetrical and asymmetrical airfoils are targeted in our study, presenting comprehensive results to validate our methodology

🔖

Bu Makaleye Atıf Yap

BATİSTA, N. C., MELILIO, R., MENDES, V. M. (2018). Darrieus vertical axis wind turbines: methodology to study the self-start capabilities considering symmetric and asymmetric airfoils. Research on Engineering Structures and Materials, Cilt: 4 - Sayı: 3, 189–217. https://ajindex.com/articles/302628

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. Francese D., Adamo E., Khanmohammadi S. Micro-aeolic in residential districts: a Case study in Sant'Arsenio (south-western Italy). Mediterranean Green Buildings and Renewable Energy 2017; 369-377. Jäger-Waldau A. PV Status Report 2017. Publications Office of the European Union 2017.
  2. Melicio R., Mendes V.M.F., Catalão J.P.S. Computer simulation of wind power systems: power electronics and transient stability analysis. Proceedings of the Int. Conference on Power Systems Transients (IPST 2009), 1–7,
  3. Kyoto, Japan, June 2009.
  4. Batista N.C., Melicio R., Matias J.C.O, Catalão J.P.S. ZigBee standard in the creation of wireless networks for advanced metering infrastructures. Proceedings of the 16th IEEE Mediterranean Electrotechnical Conference, 220–223,
  5. Medina Yasmine Hammamet, Tunisia, March 2012. https://doi.org/10.1109/MELCON.2012.6196418
  6. Melicio R., Mendes V.M.F., Catalão J.P.S. Modeling, control and simulation of full-power converter wind turbines equipped with permanent magnet synchronous generator. International Review of Electrical Engineering 2010; 5(2): 397-408.
  7. Melicio R., Mendes V.M.F., Catalão J.P.S. Modeling and simulation of wind energy systems with matrix and multilevel power converters. IEEE Latin America Transactions 2009; 7(1): 78-84. https://doi.org/10.1109/TLA.2009.5173468
  8. Arab A., Javadi M., Anbarsooz M., Moghiman M. A numerical study on the aerodynamic performance and the self-starting characteristics of a Darrieus wind turbine considering its moment of inertia. Renewable Energy 2017; 107: 298-311. https://doi.org/10.1016/j.renene.2017.02.013
  9. D'Alessandro V., Montelpare S., Ricci R., Secchiaroli A. Unsteady aerodynamics of a Savonius wind rotor: a new computational approach for the simulation of energy performance. Energy, 2010; 35: 3349-3363. https://doi.org/10.1016/j.energy.2010.04.021
  10. Shigetomi A., Murai Y., Tasaka Y., Takeda Y. Interactive flow field around two Savonius turbines. Renewable and Sustainable Energy Reviews, 2011; 36: 536-545. https://doi.org/10.1016/j.renene.2010.06.036
  11. Hill N., Dominy R., Ingram G., Dominy J. Darrieus turbines: the physics of self-starting. Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy, 2009; 223: 21 – 29. https://doi.org/10.1243/09576509JPE615
  12. Castelli M.R., Englaro A., Benini E. The Darrieus wind turbine: proposal for a new performance prediction model based on CFD. Energy, 2011; 36: 4919 – 4934. https://doi.org/10.1016/j.energy.2011.05.036
  13. Kjellin J., Bulow