Dergiler / Research on Engineering Structures and Materials / 2020 / Cilt: 6 - Sayı: 3

Impact of energy efficient design parameters on energy consumption in hot-humid climate zones

Sayfa
197–206
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

In addition to this, as of the early design phase, the energy efficient design of the building is of great importance in terms of a holistic evaluation and maximum energy efficiency

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:In this study; based on energy-efficient design parameters, the effects of building design parameters on the energy consumption of the building were examined.
📊
Temel Bulgular & Veri:The model has been transferred to Green Building Studio (GBS) for energy performance analysis and evaluation of design alternatives.
💡
Sonuç & Katkı:In addition to this, as of the early design phase, the energy efficient design of the building is of great importance in terms of a holistic evaluation and maximum energy efficiency
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

In this study; based on energy-efficient design parameters, the effects of building design parameters on the energy consumption of the building were examined. Accordingly, a reference building has been created as an example of application in the hot-humid climate zone. In the process of modelling the building, BIM (Building Information Modelling) software Autodesk Revit was used. The model has been transferred to Green Building Studio (GBS) for energy performance analysis and evaluation of design alternatives. The parameters evaluated in terms of energy consumption of the building were selected from among the design alternatives produced by GBS, based on energy-efficient design parameters. As a result of the energy performance analysis of the reference building via GBS, the building's annual electricity consumption is 35,137 kWh and the annual fuel consumption is 93,729 MJ. Based on the evaluation of selected design parameters as a result of reference building energy performance analysis; HVAC systems have been found to have the most impact on energy consumption (rates of changes; 36.83% in annual electricity consumption, 90.27% in annual fuel consumption). HVAC systems, selected to be highly efficient and suitable for climate type, have the potential to save significant energy in the amount of energy consumption throughout the life cycle. In addition to this, as of the early design phase, the energy efficient design of the building is of great importance in terms of a holistic evaluation and maximum energy efficiency

🔖

Bu Makaleye Atıf Yap

YAKUT, M. Z., ESEN, S. (2020). Impact of energy efficient design parameters on energy consumption in hot-humid climate zones. Research on Engineering Structures and Materials, Cilt: 6 - Sayı: 3, 197–206. https://ajindex.com/articles/302593

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. BP Energy. BP Energy Outlook 2019 Edition, 29, 2019
  2. Turk Ž, Klinc R, Ma Z. Towards a Parsimonious Information Management for Energy Retrofitting of Buildings. Proceedings of the Creative Construction Conference, Budapest, Hungary, 490 - 495, 2019.
  3. Khoshdelnezamiha G, Liew SC, Bong VNS, Ong DEL. BIM-based Approach for Green Buildings in Malaysia. Earth and Environmental Science, 2018;268(2019):1-8.
  4. Ebrahim A, Wayal AS, Cook M. BIM Based Building Performance Analysis Of A Green Office Building. International Journal Of Scientific & Technology Research, 2019;8(08):566-573
  5. Lu Y, Wu Z, Chang R, Lİ Y. Building Information Modeling (BIM) for green buildings: A critical review and future directions. Automation in Construction, 2017;83(2017):134- 148.
  6. Xu G, He Y. Research on Decoration Design of Green Building Based on BIM Technology. Earth and Environmental Science, 2019;242(2019):1-7.
  7. Gerrish K, Ruikar K, Cook M. Using BIM Capabilities to İmprove Existing Building Energy Modelling Practices. Engineering, Construction and Architectural Management, 2017;24(2):190-208.
  8. Gao H, Koch C, Yupeng W. Building information modelling based building energy modelling: A review. Applied Energy, 2019;238(2019):320-343.
  9. Kim JU, Hadadi OA, Kim H, Kim J. Development of A BIM-Based Maintenance Decision Making Framework for the Optimization between Energy Efficiency and Investment Costs. Sustainability, 2018;10:1-15.
  10. Abanda FH, Byers L. An İnvestigation of the Impact of Building Orientation on Energy Consumption in A Domestic Building Using Emerging BIM(Building İnformation Modelling). Energy, 2016;97:517-527.
  11. Kim S, Zadeh PA, Staub-French S, Froese T, Terim Cavka B. Assessment of the Impact of Window Size, Position and Orientation on Building Energy Load Using BIM. Procedia Engineering, 2016;145:1424-1431.
  12. Sorgato MJ, Melo AP, Lamberts R. The Effect of Window Opening Ventilation Control on Residential Building Energy Consumption. Energy and Buildings, 2016;133:1-13.
  13. Mujeebu MA, Ashraf N, Alsuwayigh A