Dergiler / Mathematical and Computational Applications / 1996 / Cilt: 1 - Sayı: 2

A cost-effective method for ultrasound volumetric imaging

Sayfa
127–132
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The technique reduces the number of firings and therefore allows real-time imaging with very low susceptibility to motion artifacts.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:A synthetic receive aperture technique is explored for cost-effective ultrasound scanners with high frame rates and beam density.
📊
Temel Bulgular & Veri:The technique provides ultrasound volumetric imaging where beam count is very large with 2-D transducer arrays using subaperture processing.
💡
Sonuç & Katkı:The technique reduces the number of firings and therefore allows real-time imaging with very low susceptibility to motion artifacts.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

A synthetic receive aperture technique is explored for cost-effective ultrasound scanners with high frame rates and beam density. The technique provides ultrasound volumetric imaging where beam count is very large with 2-D transducer arrays using subaperture processing. For every beam Ene, transmit beam is performed with a small subaperture whereas the reflected echo signals are received from non-overlapping subapertures. For every transmit-receive subaperture combination, a small number of beams are acquired and then the number of beam lines is increased through beam space interpolation. A 2-D linear filter with a different spatial frequency band for each subaperture is employed as the interpolation filter. Performance of the technique is analyzed through simulations. The technique reduces the number of firings and therefore allows real-time imaging with very low susceptibility to motion artifacts.

🔖

Bu Makaleye Atıf Yap

UÇAR, F. N., KARAMAN, M. (1996). A cost-effective method for ultrasound volumetric imaging. Mathematical and Computational Applications, Cilt: 1 - Sayı: 2, 127–132. https://ajindex.com/articles/280224

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (9)

  1. B. D. Steinberg, "Digital beamforming in ultrasound," IEEE Trans. Ultrason Ferroelect. Freq. Cont., vol. 39, pp.116-721, Nov. 1992
  2. Y. Ozaki, H. Sumitani, T.Tomoda and M.Tanaka, "A new system for real time synthetic aperture ultrasonic imaging," IEEE Trans. Ultrason Ferroelect. Freq. Cont., vol. 35, pp.828-838, Nov. 1988
  3. M. Karaman, P. C. Li and M. O'Donnell, " Synthetic aparture imaging for small scale systems," IEEE Trans. Ultrason Ferroelect. Freq. Cont., vol. 42, no.3, pp 429-441 May 1995
  4. O. T. V. Ranun and S.W. Smith, "Beam steering with linear arrays," IEEE Trans. Biomedical Engineering., vol. 30, no. 8, pp 438-452 Nov. 1995
  5. L. F. Nock and G.E.Trahey, "Synthetic receive aparture imaging with phase correction for motion and for tissue inhomogeneities-Part I:basic principles," IEEE Trans. Ultrason Ferroelect. Freq. Cont., vol. 39, no.3, pp.489-495, July 1992
  6. K. Nagai, "A new synthetic-aperture focusing method for ultrasonic B-scan imaging by the Fourier transform," IEEE Trans. Sonics. Ultrason., vol. 32, pp.531-536, July 1985
  7. W. C. Curtis, "Synthetic aperture fundamentals," in E. Brookner, ed., Radar Technology., pp. 231- 237. Artec Hause, 1978. chap. 16
  8. S. W. Smith, H. G. Pavy, 0. T. von Ramm, "High-speed ultrasound volumetric imaging system-Part I: transducer design and beam steering," IEEE Trans. Ultrason Ferroelect. Freq. Cont., vol. 38, pp.101-108, March 1991
  9. B. D. Steinberg, Principles of Aperture and Array System Design. New York: Wiley, 1976.