Journals / Mathematical and Computational Applications / 1996 / Cilt: 1 - Sayı: 2

A cost-effective method for ultrasound volumetric imaging

Pages
127–132
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The technique reduces the number of firings and therefore allows real-time imaging with very low susceptibility to motion artifacts.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:A synthetic receive aperture technique is explored for cost-effective ultrasound scanners with high frame rates and beam density.
📊
Key Findings & Data:The technique provides ultrasound volumetric imaging where beam count is very large with 2-D transducer arrays using subaperture processing.
💡
Conclusion & Impact:The technique reduces the number of firings and therefore allows real-time imaging with very low susceptibility to motion artifacts.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

A synthetic receive aperture technique is explored for cost-effective ultrasound scanners with high frame rates and beam density. The technique provides ultrasound volumetric imaging where beam count is very large with 2-D transducer arrays using subaperture processing. For every beam Ene, transmit beam is performed with a small subaperture whereas the reflected echo signals are received from non-overlapping subapertures. For every transmit-receive subaperture combination, a small number of beams are acquired and then the number of beam lines is increased through beam space interpolation. A 2-D linear filter with a different spatial frequency band for each subaperture is employed as the interpolation filter. Performance of the technique is analyzed through simulations. The technique reduces the number of firings and therefore allows real-time imaging with very low susceptibility to motion artifacts.

🔖

Cite This Article

UÇAR, F. N., KARAMAN, M. (1996). A cost-effective method for ultrasound volumetric imaging. Mathematical and Computational Applications, Cilt: 1 - Sayı: 2, 127–132. https://ajindex.com/articles/280224

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (9)

  1. B. D. Steinberg, "Digital beamforming in ultrasound," IEEE Trans. Ultrason Ferroelect. Freq. Cont., vol. 39, pp.116-721, Nov. 1992
  2. Y. Ozaki, H. Sumitani, T.Tomoda and M.Tanaka, "A new system for real time synthetic aperture ultrasonic imaging," IEEE Trans. Ultrason Ferroelect. Freq. Cont., vol. 35, pp.828-838, Nov. 1988
  3. M. Karaman, P. C. Li and M. O'Donnell, " Synthetic aparture imaging for small scale systems," IEEE Trans. Ultrason Ferroelect. Freq. Cont., vol. 42, no.3, pp 429-441 May 1995
  4. O. T. V. Ranun and S.W. Smith, "Beam steering with linear arrays," IEEE Trans. Biomedical Engineering., vol. 30, no. 8, pp 438-452 Nov. 1995
  5. L. F. Nock and G.E.Trahey, "Synthetic receive aparture imaging with phase correction for motion and for tissue inhomogeneities-Part I:basic principles," IEEE Trans. Ultrason Ferroelect. Freq. Cont., vol. 39, no.3, pp.489-495, July 1992
  6. K. Nagai, "A new synthetic-aperture focusing method for ultrasonic B-scan imaging by the Fourier transform," IEEE Trans. Sonics. Ultrason., vol. 32, pp.531-536, July 1985
  7. W. C. Curtis, "Synthetic aperture fundamentals," in E. Brookner, ed., Radar Technology., pp. 231- 237. Artec Hause, 1978. chap. 16
  8. S. W. Smith, H. G. Pavy, 0. T. von Ramm, "High-speed ultrasound volumetric imaging system-Part I: transducer design and beam steering," IEEE Trans. Ultrason Ferroelect. Freq. Cont., vol. 38, pp.101-108, March 1991
  9. B. D. Steinberg, Principles of Aperture and Array System Design. New York: Wiley, 1976.