Macro-TSH Can be a Rare Cause of Elevated Serum Thyroid Stimulating Hormone Concentration: A Case Report

Sayfa
1691–1696
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

To avoid unnecessary investigations and treatment, macro-TSH should be kept in mind in patients with high TSH levels without symptoms of hypothyroidism in the differential diagnosis.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:In this case report, an 18 years old female subject with incidentally detected thyroid stimulating hormon (TSH) elevation due to macro-TSH without clinical findings of thyroid disorder was defined.
📊
Temel Bulgular & Veri:Initially, the laboratory investigations revealed high TSH [11.45 µIU/mL; normal reference interval (NRI: 0.50-5.50 µIU/mL)] with electrochemiluminescence immunoassay (ECLIA) method.
💡
Sonuç & Katkı:To avoid unnecessary investigations and treatment, macro-TSH should be kept in mind in patients with high TSH levels without symptoms of hypothyroidism in the differential diagnosis.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

In this case report, an 18 years old female subject with incidentally detected thyroid stimulating hormon (TSH) elevation due to macro-TSH without clinical findings of thyroid disorder was defined. Initially, the laboratory investigations revealed high TSH [11.45 µIU/mL; normal reference interval (NRI: 0.50-5.50 µIU/mL)] with electrochemiluminescence immunoassay (ECLIA) method. When L-thyroxine and L-triodothyronine treatments were found to be ineffective for lowering TSH, polyethylene glycol (PEG) method for TSH measurement was planned to rule out the posibility of macro-TSH. TSH level upon using the PEG method was found to be within normal ranges as 1.96 µIU/mL. In conclusion, normal free thyroxine level accompanied by elevated TSH is mostly encountered in cases of subclinical hypothyroidism. Such a laboratory finding can also be caused by macro-TSH which is a rare condition. To avoid unnecessary investigations and treatment, macro-TSH should be kept in mind in patients with high TSH levels without symptoms of hypothyroidism in the differential diagnosis.

🔖

Bu Makaleye Atıf Yap

PEYNİRCİ, H., ERSOY, C., ŞAHİN, A., İMAMOĞLU, Ş. (2014). Macro-TSH Can be a Rare Cause of Elevated Serum Thyroid Stimulating Hormone Concentration: A Case Report. Medicine Science, Cilt: 3 - Sayı: 4, 1691–1696. https://ajindex.com/articles/277977

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. Loh TP, Kao SL, Halsall DJ, Toh SA, Chan E, Ho SC, Tai ES, Khoo CM. Macrothyrotropin: a case report and review of literature. J Clin Endocrinol Metab. 2012;97(6):1823-8
  2. Mills F, Jeffery J, Mackenzie P, Cranfield A, Ayling RM. An immunoglobulin G complexed form of thyroid-stimulating hormone (macro thyroid-stimulating hormone) is a cause of elevated serum thyroid-stimulating hormone concentration. Ann Clin Biochem. 2013;50(Pt 5):416-20
  3. Cooper DS, Ladenson PW. The thyroid gland. In: Gardner DG, Shoback D, eds, Greenspan's Basic and Clinical Endocrinology, 9th edition. New York: The McGraw Hill Companies. 2011;163-226
  4. Melmed S, Kleinberg D, Ho K. Pituitary physiology and diagnostic evaluation. In: Melmed S, Polonsky KS, Larsen PR, Kronenberg HM, eds, William's Textbook of Endocrinology, 12th edition. USA: Elsevier Saunders. 2011;175-228
  5. Després N, Grant AM. Antibody interference in thyroid assays: a potential for clinical misinformation. Clin Chem. 1998;44(3):440-54
  6. Mendoza H, Connacher A, Srivastava R. Unexplained high thyroid stimulating hormone: a "BIG" problem. BMJ Case Rep. pii:bcr01.2009.1474
  7. Verhoye E, Van den Bruel A, Delanghe JR, Debruyne E, Langlois MR. Spuriously high thyrotropin values due to anti-thyrotropin antibodies in adult patients. Clin Chem Lab Med. 2009;47(5):604-6
  8. Lazarus J H, John R, Ginsberg J, Hughes IA, Shewring G, Smith BR, Woodhead JS, Hall R. Transient neonatal hyperthyrotrophinaemia: a serum abnormality due to transplacentally acquired antibody to thyroid stimulating hormone. Br Med J (Clin Res Ed). 1983;286(6365):592-4
  9. Rix M, Laurberg P, Porzig C, Kristensen SR. Elevated thyroid-stimulating hormone level in a euthyroid neonate caused by macro thyrotropin-IgG complex. Acta Paediatr. 2011;100(9):e135-7
  10. Halsall DJ, Fahie-Wilson MN, Hall SK, Barker P, Anderson J, Gama R, Chatterjee VK. Macro thyrotropin-IgG complex causes factitious increases in thyroidstimulating hormone screening tests in a neonate and mother. Clin Chem. 2006;52(10):1968-9
  11. Sakai H, Fukuda G, Suzuki N, Watanabe C, Odawara M. Falsely elevated thyroidstimulating hormone (TSH) level due to macro-TSH. Endocr J. 2009;56(3):435- 40
  12. Vieira JG, Maciel RM, Hauache OM, Nishida SK, Boelter DM, Pinheiro MF. Unexpected high values of TSH: the presence of high molecular weight forms (macro TSH) must be investigated. Arq Bras Endocrinol Metabol. 2006;50(3):445- 9.