Dergiler / Gazi University Journal of Science / 2018 / Cilt: 31 - Sayı: 1

Electrochemical Behaviour of Ofloxacin in Pharmaceutical and Biological Samples Using a Boron-Doped Diamond Electrode in Using Anionic Surfactant

Sayfa
66–80
Yayın Tarihi
2018-03-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

In this way, BDD electrode may represent an efficient alternative to widely used modified electrodes in the determination of fluoroquinolone compounds.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:This paper examined use of a boron doped diamond electrode (BDDE) for the electroanalysis of ofloxacin (one of the fluoroquinolone compounds) by cyclic voltammetry (CV) and square wave voltammetry (SWV) in the presence of anionic surfactant (SDS) for the first time.
📊
Temel Bulgular & Veri:The current signal due to the oxidation process was a function of the amount of ofloxacin, pH of the medium, effect of anionic surfactant (sodium dodecyl sulfate) and scan rate.
💡
Sonuç & Katkı:In this way, BDD electrode may represent an efficient alternative to widely used modified electrodes in the determination of fluoroquinolone compounds.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Ofloxacin · Sodium Dodecyl Sulfate · Boron-Doped Diamond Electrode

Abstract

This paper examined use of a boron doped diamond electrode (BDDE) for the electroanalysis of ofloxacin (one of the fluoroquinolone compounds) by cyclic voltammetry (CV) and square wave voltammetry (SWV) in the presence of anionic surfactant (SDS) for the first time. The current signal due to the oxidation process was a function of the amount of ofloxacin, pH of the medium, effect of anionic surfactant (sodium dodecyl sulfate) and scan rate. Cyclic voltammetric studies indicated an irreversible behaviour of ofloxacin in phosphate buffer solution at pH 2.0 with well-defined oxidation peak at +1.24 V (absence SDS) and +1.21 V (presence of SDS) vs. Ag/AgCl, respectively. With optimized experimental parameters, the current response of ofloxacin was proportionally linear in the concentration range from 1.0×10-7 to 3.5×10-6 M. A detection limit of 1.76×10-8 M was observed anodically electrochemical surface pretreatments. The practical applicability of the developed method was demonstrated on the determination of ofloxacin in human urine and pharmaceutical samples. In this way, BDD electrode may represent an efficient alternative to widely used modified electrodes in the determination of fluoroquinolone compounds.

🔖

Bu Makaleye Atıf Yap

PINAR, P. T. (2018). Electrochemical Behaviour of Ofloxacin in Pharmaceutical and Biological Samples Using a Boron-Doped Diamond Electrode in Using Anionic Surfactant. Gazi University Journal of Science, Cilt: 31 - Sayı: 1, 66–80. https://ajindex.com/articles/254676

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (10)

  1. Li, R., Lv, S., Shan, J., Zhang, J., ‘A novel electrochemical method for ofloxacin determination based on interaction of ofloxacin with cupric ion’, Ionics 21(11): 3117–3124, (2015)
  2. Golcu, A., ‘Ofloxacin metal complexes: synthesis, characterization, analytical properties, and DNA binding studies’, Synth. react. inorg. met.-org. nano-met. chem., 44(10): 1509-1520, (2014)
  3. Ballesteros, O., Vı́lchez, J. L., Navalón, A.’Determination of the antibacterial ofloxacin in human urine and serum samples by solid-phase spectrofluorimetry’, J. Pharm. Biomed. Anal., 30(4): 1103–1110, (2002)
  4. Yang, C., Xu, Y., Hu, C., Hu, S.,‘Voltammetric detection of ofloxacin in human urine at a Congo Red functionalized water-soluble carbon nanotube film Electrode’, Electroanalysis, 20(2): 144-149, (2008)
  5. Vosough, M., Rashvand, M., Esfahani, H.M., Kargosha, K., Salemi, A.,’Direct analysis of six antibiotics in wastewater samples using rapid high-performance liquid chromatography coupled with diode array detector: A chemometric study towards green analytical chemistry’, Talanta 135(1): 7–17, (2015)
  6. Cañada-Cañada, F., Espinosa-Mansilla, A., Muñoz de la Peña, A.,’Separation of fifteen quinolones by high performance liquid chromatography: Application to pharmaceuticals and ofloxacin determination in urine’, J. Sep. Sci. 30(9): 1242 – 1249, (2007)
  7. Espinosa-Mansilla, A., Muñoz de la Peña, A., González Gómez, D., Salinas, F.,’HPLC determination of enoxacin, ciprofloxacin, norfloxacin and ofloxacin with photoinduced fluorimetric (PIF) detection and multiemission scanning: Application to urine and serum’, J. Chromatogr. B, 822(1-2): 185-193, (2005)
  8. Immanuel, C., Hemanth Kumar, A. K.,’Simple and rapid high-performance liquid chromatography method for the determination of ofloxacin concentrations in plasma and urine’, J. Chromatogr. B Biomed. Sci. Appl., 760(1): 91-95, (2001)
  9. Puranik, M., Bhawsar, D. V., Rathi, P., Yeole, P.G.,’Simultaneous determination of ofloxacin and ornidazole in solid dosage form by RP-HPLC and HPTLC techniques’, The indian journal of pharmaceutical sciences, 72(4): 513-517, (2010)
  10. Kraemer, H., Gehrke, R., Breithaupt, A., Breithaupt, H.,’Simultaneous quantification of cefotaxime, desacetylcefotaxime, ofloxacine and ciprofloxacine in ocular aqueous humor and in plasma by high-performance liquid chromatography’, J. Chromatogr. B 700(1-2): 147-153, (1997). Refe