Dergiler / Gazi University Journal of Science / 2019 / Cilt: 32 - Sayı: 2

Non-Linear Eddy Current Loss and Thermal Analysis on Transformer Cover

Sayfa
558–570
Yayın Tarihi
2019-06-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The reliability of the technique, confirmed by experimental and FEM results.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:High current conductors of transformers cause to produce losses and thermal problems in their tank cover.
📊
Temel Bulgular & Veri:Finite Difference (FD) Method (FDM) magnetic analysis is used to find out an exact estimation of the magnetic field and the losses near the bushings in the transient solution, considering the non-linear magnetic permeability of the cover plate, because FDM is more flexible to deal with the nonlinear constitutive law and easy-to-be implemented especially in the case of simple geometry.
💡
Sonuç & Katkı:The reliability of the technique, confirmed by experimental and FEM results.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Eddy current loss · Finite Difference method · Finite element simulation

Abstract

High current conductors of transformers cause to produce losses and thermal problems in their tank cover. Finite Difference (FD) Method (FDM) magnetic analysis is used to find out an exact estimation of the magnetic field and the losses near the bushings in the transient solution, considering the non-linear magnetic permeability of the cover plate, because FDM is more flexible to deal with the nonlinear constitutive law and easy-to-be implemented especially in the case of simple geometry. Finite Element Method (FEM) thermal analysis is used to determine the plate temperature based on magnetic FD analysis, taking account non-linear heat flux boundary condition. A calibration procedure is used between the analyses to ensure the precision of assumptions. The reliability of the technique, confirmed by experimental and FEM results.

🔖

Bu Makaleye Atıf Yap

ZAHEDI, M. Z., ISKENDER, İ. (2019). Non-Linear Eddy Current Loss and Thermal Analysis on Transformer Cover. Gazi University Journal of Science, Cilt: 32 - Sayı: 2, 558–570. https://ajindex.com/articles/254538

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. Turowski, J. and Pelikant, A., "Eddy Currents Losses and Hot-Spot Evaluation in Cover Plates of Power Transformers," Proc. Inst. Elect. Eng. Elect. Power Appl., vol. 144, no. 6, pp. 435-440, (1997).
  2. Olivares, J. C., Perez, R. E., Kulkarni, S. V., Leon, F. d., and Vega, M. A. V., "2D Finite-Element Determination of Tank Wall Losses in Pad-Mounted Transformers," Electric Power Systems Research, vol. 71, pp. 179-185, (2004).
  3. Zahedi, M. Z. and Iskender, I., "3D FEM Optimal Design of Transformer Cover Plates to Decrease Stray Losses and Hot Spot Temperature," International Journal on Technical and Physical Problems of Engineering (IJTPE), vol. 8, no. 3, pp. 56-60, (2016).
  4. Olivares, J. C., Perez, R. E., Kulkarni, S. V., Leon, F. d., Vasquez, E. M., and Anaya, O. H., "Improved Insert Geometry for Reducing Tank-Wall Losses in Pad-Mounted Transformers," IEEE Trans. on Power Delivery, vol. 19, no. 3, pp. 1120-1126, (2004).
  5. Vecchio, R. M. D., Poulin, B., Feghali, P. T., Shah, D. M., and Ahuja, R., Transformer Design Principles: With Applications to Core-Form Power Transformers, USA: CRC Press,
  6. Boca Raton, FL, (2010).
  7. Maximov, S., Olivares-Galvan, J. C., Magdaleno-Adame, S., Escarela-Perez, R., and Campero-Littlewood, E., "New Analytical Formulas for Electromagnetic Field and Eddy Current Losses in Bushing Regions of Transformers," IEEE Trans. Magnetics, vol. 51, (2015).
  8. Zahedi, M. Z. and Iskender, I., "FDM ELECTROMAGNETIC ANALYSIS IN BUSHING REGIONS OF TRANSFORMER," International Journal on Technical and Physical Problems of Engineering (IJTPE), vol. 10, no. 34, pp. 27-33,
  9. Mar. (2018).
  10. Lopez-Fernandez, X. M., Penabad-Duran, P., Turowski, J., and Ribeiro, P. M., "Non-linear heating hazard assessment on transformer covers and tank walls," Przeglad Elektrotech. (Elect. Rev.), vol. 88, no. 7b, pp. 28–31, (2012).[9] Vecchio, R. M. D. and Ahuja, R., "Analytic Nonlinear Correction to the Impedance Boundary Condition," IEEE Trans. Magnetics, vol. 49, no. 12, pp. 5687–5691, (2013).
  11. S. Maximov, R. E. P., Adame, S. M., Galvan, J. C. O., and Littlewood, E. C., "Calculation of Nonlinear Electromagnetic Fields in the Steel Wall Vicinity of Transformer Bushings," IEEE Trans. Magnetics, vol. 51, no. 6, (2015).
  12. Fernandez, X. M. L., Duran, P. P., and Turowski, J., "Three Dimensional Methodology for the Overheating Hazard Assessment on Transformer Covers," IEEE Trans. Industry Applications, vol. 48, pp. 1549-1555, (2012).
  13. Durana, P. P., Fernandez, X. M. L., and Turowski, J., "3D Non-Li