Dergiler / Atmospheric Pollution Research / 2017 / Cilt: 8 - Sayı: 5

Polycyclic aromatic hydrocarbons in filterable PM2.5 emissions generated from regulated stationary sources in the metropolitan area of Costa Rica

Sayfa
843–849
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Among the diagnostic concentration ratios examined, only BaP/(BaPþChr), BaA/Chr, BaA/BaP and Pyr/BaP coefficients demonstrated codependency on the type of fuel used.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:This study analyzed the profiles of polycyclic aromatic hydrocarbons (PAHs) in filterable PM2.5 particles collected from a total of 71 boilers and 22 indirect type furnaces that burn liquid and biomass fuels in the Metropolitan Area of Costa Rica, from February 2014 to November 2015.
📊
Temel Bulgular & Veri:Modified method NIOSH 5506 was used to analyze PAHs content present in the filter samples.
💡
Sonuç & Katkı:Among the diagnostic concentration ratios examined, only BaP/(BaPþChr), BaA/Chr, BaA/BaP and Pyr/BaP coefficients demonstrated codependency on the type of fuel used.
🔬Tür:Araştırma Makalesi
📍Kapsam:2014 Verileri
⚙️Değişkenler:Alan Parametreleri

Özet

This study analyzed the profiles of polycyclic aromatic hydrocarbons (PAHs) in filterable PM2.5 particles collected from a total of 71 boilers and 22 indirect type furnaces that burn liquid and biomass fuels in the Metropolitan Area of Costa Rica, from February 2014 to November 2015. Modified method NIOSH 5506 was used to analyze PAHs content present in the filter samples. The average concentration of PM2.5 showed values between 18 and 735 mg m 3, based on the source and fuel type used, while the total PAHs in the PM2.5 fraction ranged 1.02e592 mgm 3. For biomass boilers, the most abundant species were Benzo[g,h,i]perylene (BghiP) (35.7e46.5%), Indeno[1,2,3-cd]pyrene (IND) (20.6e27.1%), Benzo[a]pyrene (BaP) (5.2e14.7%) and Dibenzo[a,h]anthracene (DBA) (3.2e13.9%), while for liquid fuels IND (12.8 e20.5%), BghiP (7.9e21.2%), Fluoranthene (Flu) (14.5e21.3%) and Pyrene (Pyr) (9.8e14.5%) prevailed. The particles from biomass furnace emissions present higher concentrations of PAHs classified by the U.S. EPA as probable human carcinogens causing a greater health risk than other fuels. Among the diagnostic concentration ratios examined, only BaP/(BaPþChr), BaA/Chr, BaA/BaP and Pyr/BaP coefficients demonstrated codependency on the type of fuel used.

🔖

Bu Makaleye Atıf Yap

MURİLLO, J. H., MARİN, J. F. R., ALVAREZ, V. M., ARİAS, D. S., GUERRERO, V. H. B. (2017). Polycyclic aromatic hydrocarbons in filterable PM2.5 emissions generated from regulated stationary sources in the metropolitan area of Costa Rica. Atmospheric Pollution Research, Cilt: 8 - Sayı: 5, 843–849. https://ajindex.com/articles/214267

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (2)

  1. WHO, IARC, 2010. Monographs on the Evaluation of Carcinogenic Risks to Humans, Some Non e Heterocyclic Polycyclic Aromatic Hydrocarbons and Some Related Exposures, 92. Wei, Y.J., Han, I.K., Hu, M., Shao, M., Zhang, J.F., Tang, X.Y., 2010. Personal exposure to particulate PAHs and anthraquinone and oxidative DNA damages in humans. Chemosphere 81, 1280e1285. Wang, Y., Hopke, P., Utell, M., 2011. Urban-scale spatial-temporal variability of black carbon and winter residential wood combustion particles. Aerosol Air Qual. Res. 11, 473e481. Tobiszewski, M., Namiesnik, J., 2012. Review: PAH diagnostic ratios for the identi- fication of pollution emission sources. Environ. Pollut. 162, 110e119. Srogi, K., 2007. Monitoring of environmental exposure to polycyclic aromatic hy- drocarbons: a review. Environ. Chem. Lett. 5 (4), 169e195. Ribeiro, J., Silva, T., Graciano, J., Filho, M., Flores, D., 2012. Polycyclic aromatic hy- drocarbons (PAHs) in burning and non-burning coal waste piles. J. Hazard. Mater. 19, 105e110. Ravindra, K., Sokhi, R., Van Grieken, R., 2008. Atmospheric polycyclic aromatics hydrocarbons: source attribution, emission factors and regulation. Atmos. En- viron. 42, 2895e2921. Ministerio de Salud, 2011. Decreto 36 551 S-MINAET-MTSS Reglamento sobre emision de contaminantes atmosfericos provenientes de calderas y hornos de tipo indirecto. Diario Oficial La Gaceta N 125. Meier, P., Zund, R., 2001. Statistical Methods in Analytical Chemistry, second ed. Lima, A., Farrington, J., Reddy, C., 2005. Combustion-derived of polycyclic aromatic hydrocarbons in the environment-a review. Environ. Forensics 6, 109e131. Kong, S., Shi, J., Lu, B., Qiu, W., Zhang, B., Peng, Y., Zhang, B., Bai, Z., 2011. Charac- terization of PAHs within PM10 fraction for ashes from coke production, iron smelt, heating station and power plant stacks in Liaoning Province. Atmos. Environ. 45 (23), 3777e3785. Herrera, J., 2016. Informe de Calidad del Aire del Area Metropolitana de Costa Rica: Anos~ 2013-2015, p. 75 (Report on air quality in the metropolitan area of CostaRica: 2013-2015).
  2. Gong, P., Liang, S., Carlton, E., Jiang, Q., Wu, J., Wang, L., Remais, J., 2012. Urbani- sation and health in China. Lancet 379, 843e852. Gao, B., Guo, H., Wang, X., Zhao, X., Ling, Z., Zhang, Z., Liu, T., 2012. Polycyclic aro- matic hydrocarbons in PM2.5 in Guangzhou, southern China: spatiotemporal patterns and emission sources. J. Hazard. Mater 239, 78e87. Gadi, R., Singh, D.P., Saud, T., Mandal, T.K.,