Dergiler / Turkish Journal of Chemistry / 2020 / Cilt: 44 - Sayı: 5

Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds

Sayfa
1293–1302
Yayın Tarihi
2020-10-26
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

As a result of the study, human glucose values were determined with an average error of 3.25%.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Determining the blood glucose level is important for the prevention and treatment of diabetes mellitus.
📊
Temel Bulgular & Veri:In the first stage of the study, the QCM sensor with the highest performance was identified using artificial glucose solution concentrations.
💡
Sonuç & Katkı:As a result of the study, human glucose values were determined with an average error of 3.25%.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Phthalocyanines · blood glucose · human blood serum

Abstract

Determining the blood glucose level is important for the prevention and treatment of diabetes mellitus. We developed a sensor system using Quartz Crystal Ivlicrobalance (QCM) to determine the blood glucose level from human blood serum. This study consists of two experimental stages: artificial glucose/pure water solution tests and human blood serum tests. In the first stage of the study, the QCM sensor with the highest performance was identified using artificial glucose solution concentrations. In the second stage of the study, human blood serum measurements were performed using QCM to determine blood glucose levels. QCM sensors were coated with phthalocyanines (Pcs) by jet spray method. The blood glucose values of 96 volunteers, which ranged from 71 mg/dL to 329 mg/dL, were recorded. As a result of the study, human glucose values were determined with an average error of 3.25%.

🔖

Bu Makaleye Atıf Yap

SADİK, E. S., SARAOGLU, H. M., GUROL, I., EBEOGLU, M. A., KOCAK, F. E. (2020). Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds. Turkish Journal of Chemistry, Cilt: 44 - Sayı: 5, 1293–1302. https://ajindex.com/articles/208820

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (4)

  1. Al-Sagur H, 2019, BIOSENS BIOELECTRON, V139, DOI 10.1016/j.bios.2019.111323 Bergenstal RM, 2013, DIABETES CARE, V36, pE107, DOI 10.2337/dc13-0295 Cheng TJ, 2001, ANAL CHIM ACTA, V432, P101, DOI 10.1016/S0003-2670(00)01346-5 Erbahar DD, 2014, SENSOR ACTUAT B-CHEM, V190, P651, DOI 10.1016/j.snb.2013.09.034 Harbeck M, 2010, SENSOR ACTUAT B-CHEM, V150, P346, DOI 10.1016/j.snb.2010.06.062 Harbeck S, 2013, SENSOR ACTUAT B-CHEM, V176, P838, DOI 10.1016/j.snb.2012.08.020 Huang HH, 2004, SENSOR ACTUAT B-CHEM, V101, P316, DOI 10.1016/j.snb.2004.04.001 Juan CG, 2019, SENSORS-BASEL, V19, DOI 10.3390/s19173779 KANAZAWA KK, 1985, ANAL CHEM, V57, P1770, DOI 10.1021/ac00285a062 KANAZAWA KK, 1985, ANAL CHIM ACTA, V175, P99 Kankare J, 2002,
  2. LANGMUIR, V18, P7092, DOI 10.1021/la025911w KING WH, 1964, ANAL CHEM, V36, P1735, DOI 10.1021/ac60215a012 KONASH PL, 1980, ANAL CHEM, V52, P1929, DOI 10.1021/ac50062a033 Lin TY, 2004, BIOSENS BIOELECTRON, V20, P75, DOI 10.1016/j.bios.2004.01.028 MARTIN SJ, 1991, ANAL CHEM, V63, P2272, DOI 10.1021/ac00020a015 Muller L, 2010, ANAL CHEM, V82, P658, DOI 10.1021/ac9021117 Panda A, 2020, APPL PHYS A-MATER, V126, DOI 10.1007/s00339-020-3328-8 Rasooly A, 2005,
  3. METHODS, V37, P1, DOI 10.1016/j.ymeth.2005.05.004 Saraoglu HM, 2010, IEEE SENS J, V10, P104, DOI 10.1109/JSEN.2009.2035769 SAUERBREY G, 1959, Z PHYS, V155, P206, DOI 10.1007/BF01337937 Shoji M, 2010, POLYM ADVAN TECHNOL, V21, P646, DOI 10.1002/pat.1480 Tarakci DK, 2013, J PORPHYR PHTHALOCYA, V17, P548, DOI 10.1142/S1088424613500399 Tasaltin C, 2010, SENSOR ACTUAT B-CHEM, V150, P781, DOI 10.1016/j.snb.2010.07.056 Voinova MV, 2002, BIOSENS BIOELECTRON, V17, P835, DOI 10.1016/S0956-5663(02)00050-7 Yoshihiro T, 1999,
  4. METHOD OPTICAL RECOR, Patent No. JP 11254827 A 19990921 Yoshiyama H, 2008, CHEM COMMUN, P1977, DOI 10.1039/b800918j