Dergiler / Atmospheric Pollution Research / 2018 / Cilt: 9 - Sayı: 3

Performance studies of planetary boundary layer schemes in WRF-Chem for the Andean region of Southern Ecuador

Sayfa
411–428
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

In the future it is necessary to explore the effects in modeling of direct and indirect feedbacks, in combination with other parameterizations and aerosol-chemical mechanisms.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:In tandem with emissions, the dynamics of the Planetary Boundary Layer (PBL) strongly define the concentration of pollutants in the atmosphere.
📊
Temel Bulgular & Veri:The PBL parameterization schemes of numerical models need to be assessed to identify which one provides the best performance.
💡
Sonuç & Katkı:In the future it is necessary to explore the effects in modeling of direct and indirect feedbacks, in combination with other parameterizations and aerosol-chemical mechanisms.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:2014 Verileri
⚙️Değişkenler:Alan Parametreleri

Özet

In tandem with emissions, the dynamics of the Planetary Boundary Layer (PBL) strongly define the concentration of pollutants in the atmosphere. The PBL parameterization schemes of numerical models need to be assessed to identify which one provides the best performance. We simulated the meteorology and transport of pollutants in Cuenca (Andean region of Southern Ecuador, 2400 masl) during September 2014, using the Carbon Bond Mechanism Z (CBMZ) for gaseous species and the Model for Simulation Aerosol Interactions and Chemistry (MOSAIC) for aerosol, from the Weather Research & Forecasting with Chemistry (WRF-Chem) model. Simulations were done under 6 PBL schemes: 1 Yonsei University, YSU; 2 Mellor-Yamada-Janjic, MYJ; 3 Hong and Pang, GFS; 4 Mellor-Yamada Nakanishi and Niino Level 2.5, MYNN2; 5 Mellor-Yamada Nakanishi and Niino Level 3, MYNN3; 6 Asymmetric Convective Model PBL, ACM2. The MYJ (local, 1.5 order of closure) and YSU (nonlocal, first order of closure) schemes showed on average the best skill, with capturing 81% and 78% of shortterm air quality observations. For the MYJ scheme, the inclusion of direct effects between aerosol and meteorology increased the percentage of capturing of short and long-term air quality by 5% and 13% respectively, in comparison with modeling without feedbacks. In the future it is necessary to explore the effects in modeling of direct and indirect feedbacks, in combination with other parameterizations and aerosol-chemical mechanisms.

🔖

Bu Makaleye Atıf Yap

PARRA, R. (2018). Performance studies of planetary boundary layer schemes in WRF-Chem for the Andean region of Southern Ecuador. Atmospheric Pollution Research, Cilt: 9 - Sayı: 3, 411–428. https://ajindex.com/articles/201672

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (10)

  1. ASHRAE Standard 62.1-2007., 2007. Ventilation for Acceptable Indoor Air Quality. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA. Begum, B.A., Paul, S.K., Hossain, M.D., Biswas, S.K., Hopke, P.K., 2009. Indoor air pollution from particulate matter emissions in different households in rural areas of Bangladesh. Build. Environ. 44, 898–903.
  2. Branco, P., Alvim-Ferraz, M., Martins, F., Sousa, S., 2014. Indoor air quality in urban nurseries at Porto city: particulate matter assessment. Atmos. Environ. 84, 133–143.
  3. Deng, G., Li, Z., Wang, Z., Gao, J., Xu, Z., Li, J., Wang, Z., 2015. Indoor/outdoor relationship of PM2.5 concentration in typical buildings with and without air cleaning in Beijing. Indoor Built Environ. 26 (1), 60–69.
  4. Deng, G., Li, Z., Wang, Z., Gao, J., Xu, Z., Li, J., Wang, Z., 2017. Indoor/outdoor relationship of PM2.5 concentration in typical buildings with and without air cleaning in Beijing. Indoor Built Environ. 26, 60–68.
  5. Fan, G., Xie, J., Liu, J., Yoshino, H., 2017. Investigation of indoor environmental quality in urban dwellings with schoolchildren in Beijing, China. Indoor Built Environ. 26, 694–716. G.T. 18883-2002, 2002. Indoor Air Quality Standard of the People's Republic of China. (in Chinese). Guo, H., Morawska, L., He, C., Zhang, Y.L., Ayoko, G., Cao, M., 2010. Characterization of particle number concentrations and PM2.5 in a school: influence of outdoor air pollution on indoor air. Environ. Sci. Pollut. Res. 17, 1268–1278.
  6. Jiang, R., Bell, M.L., 2008. A comparison of particulate matter from biomass-burning rural and non-biomass-burning urban households in northeastern China. Environ. Health Perspect. 116, 907–914.
  7. Jones, A.P., 1999. Indoor air quality and health. Atmos. Environ. 33, 4535–4564.
  8. Kalimeri, K.K., Saraga, D.E., Lazaridis, V.D., Legkas, N.A., Missia, D.A., Tolis, E.I., Bartzis, J.G., 2016. Indoor air quality investigation of the school environment and estimated health risks: two-season measurements in primary schools in Kozani, Greece. Atmos. Pollut. Res. 7 (6), 1128–1142.
  9. Mainka, A., Brągoszewska, E., Kozielska, B., Pastuszka, J.S., Zajusz-Zubek, E., 2015. Indoor air quality in urban nursery schools in Gliwice, Poland: analysis of the case study. Atmos. Pollut. Res. 6 (6), 1098–1104.
  10. Massey, D.D., Kulshrestha, A., Masih, J., Taneja, A., 2012. Seasonal trends of PM10, PM5.0, PM2.5 & PM1.0 in indoor and outdoor environments of residential homes located in North-Central India. Bu