Dergiler / Atmospheric Pollution Research / 2019 / Cilt: 10 - Sayı: 1

Air quality assessment and modelling of pollutants emission from a majorcement plant complex in Nigeria

Sayfa
257–266
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Comprehensive evaluation of thefugitive emission sources should be carried out in the cement plant for immediate attention.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Cement manufacturing contributes to the elevation of air pollutants in the atmosphere and thus impact on thenearby communities.
📊
Temel Bulgular & Veri:Combustion products including SO2, NO, NO2, CO and VOCs were the gaseous pollutantsdetected along the complex fenceline and in the receptor environments.
💡
Sonuç & Katkı:Comprehensive evaluation of thefugitive emission sources should be carried out in the cement plant for immediate attention.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

Cement manufacturing contributes to the elevation of air pollutants in the atmosphere and thus impact on thenearby communities. This study assessed air quality in a major Cement Plant in Ibese Ogun State, Nigeria,through an ambient air quality monitoring and air emission dispersion modelling. Particulate Matter (PM) andgaseous pollutants were measured using portable samplers and AERMOD View was used for the emission dis-persion modelling. Combustion products including SO2, NO, NO2, CO and VOCs were the gaseous pollutantsdetected along the complex fenceline and in the receptor environments. Pollutants measurements were under-taken at 23 locations within the fence line and receptor locations. The daily SO2and NO2Federal Ministry ofEnvironment - Nigeria (FMEnv) limits were exceeded in ten (10) andfive (5) locations along the fenceline,respectively. Particulates were detected in all the locations along the fenceline and in the communities. Thecumulative gaseous pollutants resulting from simultaneous operations of all the identified plant air emissionpoint sources are 0.01–276.13% of their respective 24-h limits along the fenceline, with 1-h SO2within thethreshold limit at all fenceline locations, but 1-h NOXexceeds the threshold limit at all locations 16–21 times.The 24-h CO and VOCs are within their limits at all fenceline locations; however the 24-h SO2and NOXarebreaching the limits at some locations 30–34 times (0.34–0.39% of the investigation period) and 44–87 times,respectively. Daily and Annual averaging concentrations of PM10was 14.32–31.54% and 4.90–52.60% of theirrespective limits. Process facilities are the major point sources of atmospheric emissions identified in the factory.Several fugitive emission sources were also identified during thefield work. Comprehensive evaluation of thefugitive emission sources should be carried out in the cement plant for immediate attention.

🔖

Bu Makaleye Atıf Yap

ADENİRAN, J. A., YUSUF, R. O., FAKİNLE, B. S., SONİBARE, J. A. (2019). Air quality assessment and modelling of pollutants emission from a majorcement plant complex in Nigeria. Atmospheric Pollution Research, Cilt: 10 - Sayı: 1, 257–266. https://ajindex.com/articles/196241

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (10)

  1. Abdul-Wahab, S., Fadlallah, S., Al-Rashdi, M., 2018. Evaluation of the impact of ground-level concentrations of SO2, NOx, CO, and PM10 emitted from a steel melting planton Muscat, Oman. Sustain. Cities Soc. 38, 675–683.
  2. Abdul-Wahab, S.A., 2006. Impact of fugitive dust emissions from cement plants on nearbycommunities. Ecol. Model. 195, 338–348.
  3. Abril, G.A., Diez, S.C., Pignata, M.L., Britch, J., 2016. Particulate matter concentrationsoriginating from industrial and urban sources: validation of atmospheric dispersionmodeling results. Atmos. Pollut. Res. 7, 180–189.
  4. Adeniran, J., Yusuf, R., Olajire, A., 2017a. Exposure to coarse andfine particulate matterat and around major intra-urban traffic intersections of Ilorin metropolis, Nigeria.Atmos. Environ. 166, 383–392.
  5. Adeniran, J.A., Aremu, A.S., Saadu, Y.O., Yusuf, R.O., 2018. Particulate matter con-centration levels during intense haze event in an urban environment. Environ. Monit.Assess. 190, 41. Adeniran, J.A., Yusuf, R.O., Amole, M.O., Jimoda, L.A., Sonibare, J.A., 2017b. Air qualityimpact of diesel back-up generators (BUGs) in Nigeria's mobile telecommunicationbase transceiver stations (BTS). Manag. Environ. Qual. Int. J. 28, 723–744.
  6. Adesanmi, A., Adeniran, J., Fakinle, B., Jimoda, L., Yusuf, R., Sonibare, J., 2016. Groundlevel concentration of some air pollutants from Nigeria thermal power plants. EnergySources, Part A Recovery, Util. Environ. Eff. 38, 2426–2432.
  7. Akintunde, A., Adeniran, J., Akintunde, T., Oloyede, T., Salawu, A., Opadijo, O., 2017.P2508Air quality index and cardiovascular health among automobile technicians inNigeria: any association? Eur. Heart J. 38.Aprianti, E., 2017. A huge number of artificial waste material can be supplementarycementitious material (SCM) for concrete production–a review part II. J. Clean. Prod.142, 4178–4194.
  8. Ayer, N.W., Dias, G., 2018. Supplying renewable energy for Canadian cement production:life cycle assessment of bioenergy from forest harvest residues using mobile fastpyrolysis units. J. Clean. Prod. 175, 237–250.
  9. Bertoldi, M., Borgini, A., Tittarelli, A., Fattore, E., Cau, A., Fanelli, R., et al., 2012. Healtheffects for the population living near a cement plant: an epidemiological assessment.Environ. Int. 41, 1–7. Çetin Doğruparmak,Ş., Pekey, H., Arslanbaş, D., 2018. Odor dispersion modeling withCALPUFF: case study of a waste and residue treatment incineration and utilizationplant in Kocaeli, Turkey. Environ. Forensics 19, 79–86.
  10. Eom, S.-Y., Cho, E.-B., O