Dergiler / Turkish Journal of Chemistry / 2004 / Cilt: 28 - Sayı: 3

Anodic Stripping Voltammetric Determination of Gold on a Polyvinylferrocene Coated Glassy Carbon Electrode

Sayfa
287–298
Yayın Tarihi
2004-03-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The effects of the preconcentration period, film thickness and the presence of Cu(II) ions as possible interferants were investigated.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The anodic stripping voltammetric determination of gold was accomplished on a chemically modified glassy carbon electrode in a solution containing chloride ions.
📊
Temel Bulgular & Veri:Tetrahalo complexes of gold, tetrachloroaurate(III) and tetrabromoaurate(III) ions, were found to be reduced to metallic gold by chemical reduction during immersion of the polymer coated electrode into the solution containing aurate(III) ions.
💡
Sonuç & Katkı:The effects of the preconcentration period, film thickness and the presence of Cu(II) ions as possible interferants were investigated.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Polyvinylferrocene · modified electrode · gold determination

Özet

The anodic stripping voltammetric determination of gold was accomplished on a chemically modified glassy carbon electrode in a solution containing chloride ions. A modifying polymer, polyvinylferrocene, was coated by immersing the glassy carbon surface in its solution in methylene chloride followed by solvent evaporation. Tetrahalo complexes of gold, tetrachloroaurate(III) and tetrabromoaurate(III) ions, were found to be reduced to metallic gold by chemical reduction during immersion of the polymer coated electrode into the solution containing aurate(III) ions. This reaction was utilized as means of preconcentration without the need for cathodic electrolysis prior to the anodic stripping of metallic gold. The effects of the preconcentration period, film thickness and the presence of Cu(II) ions as possible interferants were investigated.

Abstract

The anodic stripping voltammetric determination of gold was accomplished on a chemically modified glassy carbon electrode in a solution containing chloride ions. A modifying polymer, polyvinylferrocene, was coated by immersing the glassy carbon surface in its solution in methylene chloride followed by solvent evaporation. Tetrahalo complexes of gold, tetrachloroaurate(III) and tetrabromoaurate(III) ions, were found to be reduced to metallic gold by chemical reduction during immersion of the polymer coated electrode into the solution containing aurate(III) ions. This reaction was utilized as means of preconcentration without the need for cathodic electrolysis prior to the anodic stripping of metallic gold. The effects of the preconcentration period, film thickness and the presence of Cu(II) ions as possible interferants were investigated.

🔖

Bu Makaleye Atıf Yap

KAVANOZ, M., GÜLCE, H., YILDIZ, A. (2004). Anodic Stripping Voltammetric Determination of Gold on a Polyvinylferrocene Coated Glassy Carbon Electrode. Turkish Journal of Chemistry, Cilt: 28 - Sayı: 3, 287–298. https://ajindex.com/articles/185462

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...