Dergiler / Turkish Journal of Chemistry / 2010 / Cilt: 34 - Sayı: 1

Interference elimination studies during the determination of trace elements in cow liver using differential pulse polarography

Sayfa
135–146
Yayın Tarihi
2010-01-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

It was found that the quantities for Cu, Cd, Pb, and Zn were larger in medium where interference does not take place.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The liver is known to accumulate many trace elements; thus it is very important to determine their level in a sensitive way.
📊
Temel Bulgular & Veri:It was shown that this interference could be eliminated by using pH 8.5 NaAc electrolyte.
💡
Sonuç & Katkı:It was found that the quantities for Cu, Cd, Pb, and Zn were larger in medium where interference does not take place.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Liver · trace elements · determination

Özet

The liver is known to accumulate many trace elements; thus it is very important to determine their level in a sensitive way. The objective of this study was to develop a simple method for the simultaneous determination of trace elements in cow liver in which the elimination of interference can be accomplished. It was observed that Cd, Pb, Zn, and Cu ions could not be determined correctly in the presence of Se(IV), because of interference of Se. It was shown that this interference could be eliminated by using pH 8.5 NaAc electrolyte. In this medium first Cd and Zn were determined; then, after addition of EDTA, Pb and Cu ions were determined by standard addition. Since Ti(IV), Mo(VI), Cr(III), and Fe(III) had no interference with Se(IV) they could be determined at appropriate electrolyte conditions. Selenite, on the other hand, was determined using its hydrogen catalytic peak. The results obtained under 2 conditions, where interference was eliminated and not eliminated, were compared. It was found that the quantities for Cu, Cd, Pb, and Zn were larger in medium where interference does not take place.

Abstract

The liver is known to accumulate many trace elements; thus it is very important to determine their level in a sensitive way. The objective of this study was to develop a simple method for the simultaneous determination of trace elements in cow liver in which the elimination of interference can be accomplished. It was observed that Cd, Pb, Zn, and Cu ions could not be determined correctly in the presence of Se(IV), because of interference of Se. It was shown that this interference could be eliminated by using pH 8.5 NaAc electrolyte. In this medium first Cd and Zn were determined; then, after addition of EDTA, Pb and Cu ions were determined by standard addition. Since Ti(IV), Mo(VI), Cr(III), and Fe(III) had no interference with Se(IV) they could be determined at appropriate electrolyte conditions. Selenite, on the other hand, was determined using its hydrogen catalytic peak. The results obtained under 2 conditions, where interference was eliminated and not eliminated, were compared. It was found that the quantities for Cu, Cd, Pb, and Zn were larger in medium where interference does not take place.

🔖

Bu Makaleye Atıf Yap

YILMAZ, Ü. T., SOMER, G. (2010). Interference elimination studies during the determination of trace elements in cow liver using differential pulse polarography. Turkish Journal of Chemistry, Cilt: 34 - Sayı: 1, 135–146. https://ajindex.com/articles/184938

📄 Tam Metin PDF Okuyucu

📄