Dergiler / Turkish Journal of Chemistry / 2009 / Cilt: 33 - Sayı: 4

Performance analysis for direct 2-propanol fuel-cell based on Pt containing anode electrocatalysts

Sayfa
487–499
Yayın Tarihi
2009-04-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

According to the parametric analysis, cross-over current was minimum for 0.5 M 2-propanol concentration at 40 °C operating temperature.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Direct 2-propanol cell performance based on Pt containing anode electrocatalyst was evaluated.
📊
Temel Bulgular & Veri:Cell performance, open circuit voltage, maximum current density, and maximum power density were measured at various alcohol concentrations and cell temperatures. 2-propanol fuel cell shows the highest performance at 1 M concentration and 80 °C operating temperature.
💡
Sonuç & Katkı:According to the parametric analysis, cross-over current was minimum for 0.5 M 2-propanol concentration at 40 °C operating temperature.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Propanol · Fuel cell · Performance

Özet

Direct 2-propanol cell performance based on Pt containing anode electrocatalyst was evaluated. Cell performance, open circuit voltage, maximum current density, and maximum power density were measured at various alcohol concentrations and cell temperatures. 2-propanol fuel cell shows the highest performance at 1 M concentration and 80 °C operating temperature. The highest practical efficiency (at the maximum power density) was found at 2 M 2-propanol concentration and 60 °C operating temperature. Parameter estimation was performed by non-linear least squares method using the Levenberg Marquardt algorithm. According to the parametric analysis, cross-over current was minimum for 0.5 M 2-propanol concentration at 40 °C operating temperature.

Abstract

Direct 2-propanol cell performance based on Pt containing anode electrocatalyst was evaluated. Cell performance, open circuit voltage, maximum current density, and maximum power density were measured at various alcohol concentrations and cell temperatures. 2-propanol fuel cell shows the highest performance at 1 M concentration and 80 °C operating temperature. The highest practical efficiency (at the maximum power density) was found at 2 M 2-propanol concentration and 60 °C operating temperature. Parameter estimation was performed by non-linear least squares method using the Levenberg Marquardt algorithm. According to the parametric analysis, cross-over current was minimum for 0.5 M 2-propanol concentration at 40 °C operating temperature.

🔖

Bu Makaleye Atıf Yap

TAPAN, N. A., ÖZTÜRK, E. (2009). Performance analysis for direct 2-propanol fuel-cell based on Pt containing anode electrocatalysts. Turkish Journal of Chemistry, Cilt: 33 - Sayı: 4, 487–499. https://ajindex.com/articles/184928

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...