Dergiler / Turkish Journal of Chemistry / 2016 / Cilt: 40 - Sayı: 5

Speciation of inorganic selenium by solid phase extraction using nanozirconium oxide/boron oxide composite material

Sayfa
772–783
Yayın Tarihi
2016-10-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The precision of the method was also at an acceptable level for analytical purposes for trace analysis (relative standard deviation deviation

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The speciation and preconcentration of selenium were carried out by solid phase extraction using nanozirconium oxide/boron oxide (ZrO$_{2}$/B$_{2}$O$_{3})$.
📊
Temel Bulgular & Veri:The effects of pH, flow rate, and volume of sample solution and eluent type were investigated for determining the optimum preconcentration and speciation conditions.
💡
Sonuç & Katkı:The precision of the method was also at an acceptable level for analytical purposes for trace analysis (relative standard deviation deviation
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Speciation · preconcentration · selenium

Abstract

The speciation and preconcentration of selenium were carried out by solid phase extraction using nanozirconium oxide/boron oxide (ZrO$_{2}$/B$_{2}$O$_{3})$. Electrothermal atomic absorption spectrometry (ETAAS) was used for detection. This preconcentration and/or speciation method depends on the retention of Se(IV) ions selectively as its ammonium pyrrolidine dithiocarbamate (APDC) complex on the sorbent. The effects of pH, flow rate, and volume of sample solution and eluent type were investigated for determining the optimum preconcentration and speciation conditions. The effects of other ions that may interfere with the determination and speciation of selenium were also investigated. Moreover, the analytical performance criteria of the method such as detection limit, quantification limit, linear working range, precision, and accuracy were also determined under the optimum experimental parameters. The analytical limit of detection for Se(IV) was 1.21 $\mu $g L$^{-1}$. The accuracy of the method was checked by applying it to certified reference material (NIST 1643e) and spiked water samples. It was shown that the determination could be performed with a relative error of about 10%. The precision of the method was also at an acceptable level for analytical purposes for trace analysis (relative standard deviation deviation

🔖

Bu Makaleye Atıf Yap

ERDOĞAN, H., YALÇINKAYA, Ö., TÜRKER, A. R. (2016). Speciation of inorganic selenium by solid phase extraction using nanozirconium oxide/boron oxide composite material. Turkish Journal of Chemistry, Cilt: 40 - Sayı: 5, 772–783. https://ajindex.com/articles/184634

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...