Dergiler / Turkish Journal of Chemistry / 2018 / Cilt: 42 - Sayı: 6

Metal nanoparticles/carbon nanotube modified electrodes for voltammetric determination of boron

Sayfa
1611–1622
Yayın Tarihi
2018-12-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Moreover, UME CRM 1201 (Elements in Spring Water) was used for the accuracy check of the proposed method.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:This study describes a sensitive and accurate voltammetric method for determination of boron using metal nanoparticles/carbon nanotube modified electrodes.
📊
Temel Bulgular & Veri:The oxidation peak of Alizarin Red S (ARS) at -0.59 V in the boron-ARS complex formed in ammonium/ammonia buffer solution (pH 8.5) was evaluated as a response.
💡
Sonuç & Katkı:Moreover, UME CRM 1201 (Elements in Spring Water) was used for the accuracy check of the proposed method.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Boron · Alizarin Red S · nanoparticles

Abstract

This study describes a sensitive and accurate voltammetric method for determination of boron using metal nanoparticles/carbon nanotube modified electrodes. The oxidation peak of Alizarin Red S (ARS) at -0.59 V in the boron-ARS complex formed in ammonium/ammonia buffer solution (pH 8.5) was evaluated as a response. The electrode modification conditions and experimental parameters affecting the peak height were optimized. The characteristics of modified electrodes were investigated using cyclic voltammetry, electrochemical impedance spectroscopy, scanning electron microscope, energy dispersive X-ray spectroscopy, high resolution transmission electron microscopy, and X-ray photoelectron spectroscopy. The limits of detection (3s$_{y/x})$ and the analytical ranges for gold nanoparticles/carbon nanotube modified electrode (AuNP/CNT/GCE) and copper nanoparticles/carbon nanotube modified electrode (CuNP/CNT/GCE) for 40 s accumulation times were 55 \textmu g L$^{-1}$ and 83 \textmu g L$^{-1}$ and 182-1500 \textmu g L$^{-1}$ and 278-1000 \textmu g L$^{-1}$, respectively. The method was applied to various water and eye drop samples. The results obtained for two modified electrodes were compared with inductively coupled plasma-mass spectrometry results and there was no statistically significant difference between the methods at 95% confidence level. Moreover, UME CRM 1201 (Elements in Spring Water) was used for the accuracy check of the proposed method.

🔖

Bu Makaleye Atıf Yap

LİV, L., DURSUN, Z., NAKİBOĞLU, N. (2018). Metal nanoparticles/carbon nanotube modified electrodes for voltammetric determination of boron. Turkish Journal of Chemistry, Cilt: 42 - Sayı: 6, 1611–1622. https://ajindex.com/articles/184467

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...