Air and breath analysis for the assessment of exposure to solvent emissions in university chemistry laboratories

Sayfa
1795–1802
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

These results indicate that biological monitoring using breath analysis mirror more accurately the dose inhaled in non-acute conditions and may help to assess provable chronic health effects.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:In this study, ambient and biological monitoring, through the use of breath analysis, in different university laboratory environments have been performed and compared to assess whether breath analysis is an efficient alternative for exposure monitoring in non-acute conditions. 40 atmospheric samples from four laboratories were evaluated: three of the labs used solvents on a daily basis and the manipulation of solvents was forbidden in the other laboratory. 76 breath samples were analyzed from non-exposed people (n=21) and researchers doing their regular daily routine in each of the tested laboratories (n=55).
📊
Temel Bulgular & Veri:It was found that ambient levels in the most contaminated laboratory reached values below the recommended occupational exposure limits for acute exposition.
💡
Sonuç & Katkı:These results indicate that biological monitoring using breath analysis mirror more accurately the dose inhaled in non-acute conditions and may help to assess provable chronic health effects.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

In this study, ambient and biological monitoring, through the use of breath analysis, in different university laboratory environments have been performed and compared to assess whether breath analysis is an efficient alternative for exposure monitoring in non-acute conditions. 40 atmospheric samples from four laboratories were evaluated: three of the labs used solvents on a daily basis and the manipulation of solvents was forbidden in the other laboratory. 76 breath samples were analyzed from non-exposed people (n=21) and researchers doing their regular daily routine in each of the tested laboratories (n=55). It was found that ambient levels in the most contaminated laboratory reached values below the recommended occupational exposure limits for acute exposition. However, the levels found for some of the solvents tested were above the proposed inhalation minimum risk levels (MRL) and reference concentrations (RfC) associated with chronic health effects. The results obtained for exhaled breath tend to agree with the air levels detected in the most contaminated environments, but it was found that exhaled breath levels for people working in environments with low contamination levels were not always correlated with air levels. These results indicate that biological monitoring using breath analysis mirror more accurately the dose inhaled in non-acute conditions and may help to assess provable chronic health effects.

🔖

Bu Makaleye Atıf Yap

SANCHEZ, J. M. (2019). Air and breath analysis for the assessment of exposure to solvent emissions in university chemistry laboratories. Atmospheric Pollution Research, Cilt: 10 - Sayı: 6, 1795–1802. https://ajindex.com/articles/165075

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (8)

  1. ACGIH (American Conference of Governmental Industrial Hygienists), 2001. n-Hexane. TLV(R) Chemical Substances, Cincinnati, OH. Alonso, M., Sanchez, J.M., 2013. Analytical challenges in breath analysis and its application to exposure monitoring. Trac. Trends Anal. Chem. 44, 78–89.
  2. Alonso, M., Castellanos, M., Martin, J., Sanchez, J.M., 2009. Capillary thermal desorption unit for near real-time analysis of VOCs at sub-trace levels: application to the analysis of environmental air contamination and breath samples. J. Chromatogr. B 877, 1472–1478.
  3. Alonso, M., Castellanos, M., Sanchez, J.M., 2010. Evaluation of potential breath biomarkers for active smoking: assessment of smoking habits. Anal. Bional. Chem. 396, 2987–2995.
  4. Ashford, N.A., Miller, C.S., 1998a. Chemical Exposure: Low Levels and High Stakes. Wiley, New York. Ashford, N.A., Miller, C.S., 1998b. Low-level chemical exposures: a challenge for science and policy. Environ. Sci. Technol. 32, 508A–509A. ATSDR (Agency for Toxic Substances and Disease Registry), 1999. Toxicological Profile for N-Hexane. US Department of Health and Human Services, Atlanta, GA. https:// www.atsdr.cdc.gov/toxprofiles/tp113.pdf, Accessed date: 28 January 2019. ATSDR, 2017. Minimal risk levels (MRLs) for hazardous substances. Available from: https://www.atsdr.cdc.gov/mrls/index.asp, Accessed date: 28 January 2019.
  5. Basilico, S., Garlanda, T., 1995. Occupational Exposure Limits: Criteria Document for NHexane. Report: EUR 15962 EN, Health and Safety Series. European Comission, Luxembourg. Boogaard, P.J., Hays, S.M., Aylward, L.L., 2011. Human biomonitoring as a pragmatic tool to support health risk management of chemicals – examples under the EU REACH programme. Regul. Toxicol. Pharmacol. 59, 125–132.
  6. Busby, L.D., 2017. A comparison of multiple chemical sensitivity with other hypersensitivity illnesses suggests evidence and a path to answers. Ecopsychology 9, 90–98.
  7. Castellanos, M., Xifra, G., Fernández-Real, J.M., Sanchez, J.M., 2016. Breath gas concentrations mirror exposure to sevoflurane and isopropyl alcohol in hospital environments in non-occupational conditions. J. Breath Res. 10, 016001. CDC, 2007. NIOSH pocket guide to chemical hazards. DHHS (NIOSH) Publication No. 2005-149. http://www.cdc.gov/niosh/npg, Accessed date: 28 January 2019.
  8. Coelho, L., Amorim, A., Cardeal, Z.L., 2007. Breath air analysis and its use as a biomarker in biological monitoring of occupational and environmental exposure to chemical agents. J. Chromato