An Application for Refrigerant Selecting In the Cascade Refrigeration Systems

Kademeli Soğutma Sistemlerinde Soğutucu Akışkan Seçimi İçin Bir Uygulama

Dergi
Yekarum
Sayfa
—
Yayın Tarihi
2015-05-31
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

In all cases, the refrigerant couple R134a-R407C has the highest COP and lowest irreversibility.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:In this study, energy and exergy analysis of a cascade refrigeration system was carried out.
📊
Temel Bulgular & Veri:It is assumed that the refrigeration load is 1 kW.
💡
Sonuç & Katkı:In all cases, the refrigerant couple R134a-R407C has the highest COP and lowest irreversibility.
🔬Tür:Makale
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Cascade refrigeration · Thermodynamic analysis · COP

Özet

In this study, energy and exergy analysis of a cascade refrigeration system was carried out. It is assumed that the refrigeration load is 1 kW. The temperature in condenser has been used between 50 ËšC to 60 ËšC, and the temperature in evaporator was changed between -30 ËšC to -40 ËšC. Refrigerant couples used in the cascade refrigeration system are R134a-R404A, R134a-R407C, R404A-R410A, R404A-R507, and R407C-R410A. These refrigerant couples are new generation refrigerant couples that are non-destructive to environment and to the ozone layer. The COP values and irreversibility values of the cascade refrigeration system were determined. In all cases, the refrigerant couple R134a-R407C has the highest COP and lowest irreversibility.

Abstract

Bu çalışmada kaskad soğutma sisteminin termodinamik analizi yapılmıştır. Soğutma kapasitesi 1 kW olarak kabul edilmiştir. Kondenser sıcaklığı 50 ËšC ile 60 ËšC arasında, evaporator sıcaklığı -30 ËšC ile -40 ËšC arasında değiştirilmiştir. Kaskad soğutma sisteminde soğutucu çifti olarak R134a-R404A, R134a-R407C, R404A-R410A, R404A-R507, R407C-R410 A kullanılmıştır. Bu soğutucu akışkan çiftlerinin ozon tabakasına ve çevreye yıkıcı etkisi yoktur. Kaskad soğutma sisteminin COP değerleri ve tersinmezlik değerleri belirlenmiştir. Bütün akışkan çiftlerin arasında en yüksek verim ve en düşük tersinmelik oranı R134a-R407C akışkan çiftinde elde edilmiştir.

🔖

Bu Makaleye Atıf Yap

Selbaş, R. (2015). An Application for Refrigerant Selecting In the Cascade Refrigeration Systems. Yekarum, Cilt: 3 Sayı: 1. https://ajindex.com/articles/1577697

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Kilicarslan, A., 2004. An experimental investigation of a different type vapor compression cascade refrigeration system,
  2. Applied Thermal Engineering, 24, 2611– 26
  3. Silva, A., Filho, E. P. B., Antunes, A.H.P., 2012. Comparison of a R744 cascade refrigeration system with R404A and R22 conventional systems for supermarkets, Applied Thermal Engineering, 41, 30-35.
  4. Kilicarslan, A., Hosoz, M., 2010.
  5. Energy and irreversibility analysis of a cascade refrigeration system for various refrigerant couples, Energy Conversion and Management, 51, 2947–2954. Mafi, M., Naeynian, S.M.M.,
  6. Amidpour, M., 2009. Exergy analysis of multistage cascade low temperature refrigeration systems used in olefin plants,
  7. Int. J. Refrigeration, 32, 279 – 294. Dopazo, A.J., Fernandez-Seara, J., 20 Experimental evaluation of a cascade refrigeration system prototype with CO2 and NH3 for freezing process applications, Int. J. Refrigeration, 34, 257- 2
  8. Bingming, W., Huagen, W., Jianfeng, L., Ziwen, X., 2009. Experimental investigation on the performance of
  9. NH3/CO2 cascade refrigeration system with twin-screw compressor, Int. J. Refrigeration, 32, 1358 – 1365. Messineo, A., 2012. R744-R717 Cascade Refrigeration System:
  10. Performance Evaluation compared with a HFC Two-Stage System, Energy Procedia 14, 56 – 65. Dopazo, A.J., Fernandez-Seara, J., Sieres, J., Uhia, F.J., 2009. Theoretical analysis of a CO2–NH3 cascade refrigeration system for cooling applications at low temperatures, Applied
  11. Thermal Engineering 29, 1577–1583.
  12. Bhattacharyya, S., Garaia, A., Sarkar, J., 2009. Thermodynamic analysis and optimization of a novel N2O–CO2 cascade system for refrigeration and heating, Int. J. Refrigeration, 32, 1077 – 10 Getu H.M., Bansal, P.K., 2008.
  13. Thermodynamic analysis of an R744– R717 cascade refrigeration system, Int. J. Refrigeration, 31, 45 – 54. Rezayan, O., Behbahaninia, A., 2011.
  14. Thermoeconomic optimization and exergy analysis of CO2/NH3 cascade an engineering approach. 2nd ed. McGraw-Hill.