Dergiler / Atmospheric Pollution Research / 2020 / Cilt: 11 - Sayı: 1

Spatial and temporal evaluation of H2S, SO2 and NH3 concentrations near Cerro Prieto geothermal power plant in Mexico

Sayfa
94–104
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The results indicate that GPP's emissions could affect the residents in the surrounding areas, warranting public health action to investigate exposures and risks.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Power generation is associated with toxic emissions.
📊
Temel Bulgular & Veri:Hydrogen sulfide (H2S) and ammonia (NH3) are toxic gases emitted from geothermal power generation that have negative impacts on health and the environment.
💡
Sonuç & Katkı:The results indicate that GPP's emissions could affect the residents in the surrounding areas, warranting public health action to investigate exposures and risks.
🔬Tür:Araştırma Makalesi
📍Kapsam:2013 Verileri
⚙️Değişkenler:Alan Parametreleri

Özet

Power generation is associated with toxic emissions. Hydrogen sulfide (H2S) and ammonia (NH3) are toxic gases emitted from geothermal power generation that have negative impacts on health and the environment. Oxidation of H2S leads to formation of SO2 that also has health and environmental effects. The Cerro Prieto geothermal power plant (CP-GPP) is one of the largest in the world and is located 30 km south of Mexicali, a border city between Mexico and the US. Power from this plant is sold to both countries. In order to assess the potential effects of the emissions from the GPP on nearby low-income communities, H2S, SO2 and NH3 concentrations were measured at Nuevo León, El Chimi, and Estación Delta, using passive samplers from November 2013 to June 2014. The highest concentrations of H2S were recorded during periods of high atmospheric stability, and exceeded the limit recommended by the WHO (150 μgm−3, 24-h) three times downwind from the GPP. Similarly, the mean SO2 concentrations at all three sites exceeded the limit established by the NOM-022- SSA1-2010 (288 μgm−3, 24-h), while NH3 concentrations exceeded the limits established by the OEHHA (100 μgm−3, 24-h) eight times at Nuevo León. A backward trajectory analysis indicated transport of air masses from the GPP to El Chimi and Estación Delta sampling sites. The results indicate that GPP's emissions could affect the residents in the surrounding areas, warranting public health action to investigate exposures and risks.

🔖

Bu Makaleye Atıf Yap

DODİER, L. A., CASTİLLO, J., QUİNTANA, P. J., MONTOYA, L. D., MOLİNA, L. T., ZAVALA, M., VELOZ, V. A., VENTURA, J. R. (2020). Spatial and temporal evaluation of H2S, SO2 and NH3 concentrations near Cerro Prieto geothermal power plant in Mexico. Atmospheric Pollution Research, Cilt: 11 - Sayı: 1, 94–104. https://ajindex.com/articles/157240

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (6)

  1. Adon, M., Galy-Lacaux, C., Yoboué, V., Delon, C., Lacaux, J.P., Castera, P., Gardrat, E., Pienaar, J., Al Ourabi, H., Laouali, D., Diop, B., Sigha-Nkamdjou, L., Akpo, A., Tathy, J.P., Lavenu, F., Mougin, E., 2010. Long term measurements of sulfur dioxide, nitrogen dioxide, ammonia, nitric acid and ozone in Africa using passive samplers. Atmos. Chem. Phys. 10, 7467–7487. https://doi.org/10.5194/acp-10-7467-2010.
  2. Barbier, E., 2002. Geothermal energy technology and current status: an overview. Renew. Sustain. Energy Rev. 6, 3–65. https://doi.org/10.1016/S1364-0321(02)00002-3.
  3. Barnes, I., Bastian, V., Becker, K.H., Fink, E.H., Nelsen, W., 1986. Oxidation of sulfur compounds in the atmosphere: I. Rate constants of OH radicals reactions with sulfur dioxide, hydrogen sulphide, aliphatic thiols and thiophenol. J. Atmos. Chem. 4, 445–466. https://doi.org/10.1007/BF00053845.
  4. Barrancos, J., Briz, S., Nolasco, D., Melián, G., Padilla, G., Padrón, E., Fernández, I., Pérez, N., Hernández, P.A., 2013. A new method for estimating greenhouse gases and ammonia emissions from livestock buildings. Atmos. Environ. 74, 10–17. https://doi. org/10.1016/j.atmosenv.2013.03.021. Bates, M.N., Garrett, N., Crane, J., Balmes, J.R., 2013. Associations of ambient hydrogen sulfide exposure with self-reported asthma and asthma symptoms. Environ. Res. 122, 81–87. https://doi.org/10.1016/j.envres.2013.02.002.
  5. Bei, N.F., Li, G.H., Zavala, M., Barrera, H., Torres, R., Grutter, M., Gutierrez, W., Garcia, M., Ruiz-Suarez, L.G., Ortinez, A., Guitierrez, Y., Alvarado, C., Flores, I., Molina, L.T., 2013. Meteorological overview and plume transport patterns during Cal-Mex 2010. Atm. Environ. Times 70, 477–489. https://doi.org/10.1016/j.atmosenv.2012.01. 065. Brioude, J., Angevine, W.M., McKeen, S.A., Hsie, E.-Y., 2012. Numerical uncertainty at mesoscale in a Lagrangian model in complex terrain. Geosci. Model Dev. (GMD) 5, 1127–1136. https://doi.org/10.5194/gmd-5-1127-2012.
  6. Brioude, J., Arnold, D., Stohl, A., Cassiani, M., Morton, D., Seibert, P., Angevine, W., Evan, S., Dingwell, A., Fast, J.D., Easter, R.C., Pisso, I., Burkhart, J., Wotawa, G., 2013. The Lagrangian particle dispersion model FLEXPART-WRF version 3.1. Geosci. Model Dev. 6, 1889–1904. https://doi.org/10.5194/gmd-6-1889-2013. CARB, 2016. Ambient air quality standards. Calif. Air Resources board. https://ww3.arb. ca.gov/research/aaqs/aaqs2.pdf?_ga=2.253901836.587531124.1565663701- 1417475160.1564692278. Chow Pineda, I.G., 2007. Gaussian