Dergiler / Adli Tıp Dergisi / 2011 / Cilt: 25 Sayı: 2

DETERMINATION AND METHOD VALIDATION OF HEROIN, MORPHINE, CODEINE AND 6-MONOACETYLMORPHINE BY GC-FID

Gürol Berber(Adli Tıp Kurumu)
Mesut Şahin(Adli Tıp Kurumu)
Eyüp Kandemir(Adli Tıp Kurumu)
Muhammet Nabi Kantarcı(Adli Tıp Kurumu)
Neval Berber(Adli Tıp Kurumu)
Sayfa
50–53
Yayın Tarihi
2011-08-31
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

For this reason validation and continual reclamation of methods that have been used in forensic laboratories is getting very important.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objective: This study describes the development and validation of a gas chromatography–flame ionization detection (GC–FID) method for the quantitative heroin (diacetylmorphine), morphine, codeine (3-methylmorphine) and 6-monoacetylmorphine (6 MAM) in narcotics.
📊
Temel Bulgular & Veri:Methods: In our study, GC/FID Agilent 6890N (DB-5: 10,0m x 100 µm x 0,17 µm) with Chemstation software and 5% phenylmethylpolysiloxane non polar analytic colon (max 325 °C) was used for the analyses.
💡
Sonuç & Katkı:For this reason validation and continual reclamation of methods that have been used in forensic laboratories is getting very important.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Laboratory · Quality · Validation

Abstract

Objective: This study describes the development and validation of a gas chromatography–flame ionization detection (GC–FID) method for the quantitative heroin (diacetylmorphine), morphine, codeine (3-methylmorphine) and 6-monoacetylmorphine (6 MAM) in narcotics. Methods: In our study, GC/FID Agilent 6890N (DB-5: 10,0m x 100 µm x 0,17 µm) with Chemstation software and 5% phenylmethylpolysiloxane non polar analytic colon (max 325 °C) was used for the analyses. Standards and reagents were Dichloromethaneisopropylalcohol mixture (1: 1), Methanol, HeroinHCl.H2O, CodeineHCI, MorphineHCI, 6-MonoacetylmorphineHCI, Paracetamol, caffeine and n-docosane which were used as reference standard and internal standard. Carrier gas was Helium. Injection temperature (T) was 280 ˚C, injection volume was 1 µl. Repeatability study was evaluated using 4 operators. Reproducibility study was evaluated using 3 operators during 29 days. Results: The method is linear over the range (0.01-2.00mg mL-1) for heroin, (0,008-2 mg L-1) for codeine, (0,005-2 mg mL-1) for 6-monoacetylmorphine and (0.015- 0,75mg mL-1) for morphine in the study. Correlation coefficients vary between 0.997 and 0.999 are detected. Conclusion: The increases in demanding of human rights, in getting prevalent of special insurances make it obligatory to perform total quality principles particularly for forensic disciplines. Reliability and credibility are also found very important by the courts. For this reason validation and continual reclamation of methods that have been used in forensic laboratories is getting very important.

🔖

Bu Makaleye Atıf Yap

Berber, G., Şahin, M., Kandemir, E., Kantarcı, M. N., Berber, N. (2011). DETERMINATION AND METHOD VALIDATION OF HEROIN, MORPHINE, CODEINE AND 6-MONOACETYLMORPHINE BY GC-FID. Adli Tıp Dergisi, Cilt: 25 Sayı: 2, 50–53. https://ajindex.com/articles/1352741

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Small LF, Lutz RE, editors. Chemistry of the Opium Alkaloids. U. S. Government Printing Office: Washington: DC. 1932: 153–154.
  2. Rapoport H. The Preparation of Morphine-N-Methyl-C14. J. Am. Chem. Soc. 1951;73:5900.
  3. Crews JC, Denson DD, editors. Recovery of morphine from a controlled-release preparation. A source of opioid abuse. Cancer, 1990; 66:2642–4.
  4. Trescot AM, Datta S, Lee M, et all. Opioid pharmacology. Pain Physician, 2008; 11:133–53.
  5. Baselt R, editor. Disposition of Toxic Drugs and Chemicals in Man, CA: Biomedical Publications, 8th ed. Foster City, 2008: 1057-1062.
  6. Shewan D, Dalgarno P. Evidence for contolled heroin use? High levels of negative health and social outcomes among non-treatment heroin users in glasgow. British Journal of Health Psychology, 2005; 10:33–48.
  7. Hook S, editor. The Hero in History. A Study in Limitation and Possibility. MA: Beacon Press, Boston, 1955:92-21.
  8. Sawynok J. The therapeutic use of heroin: a review of the pharmacological literature. Canadian Journal of Physiology and Pharmacology, 1986; 64:1- 6.
  9. Klous MG, Van den Brink W, Van Ree JM et all. Development of pharmaceutical heroin preparations for medical coprescription to opioid-dependent patients. Drug and Alcohol Dependence. 2005; 12;283-95.
  10. Srinivasan V, Wielbo D, Tebbett IR. Analgesic effects of codeine-6-glucuronide after intravenous administration. European journal of pain, 1997; 1:185–90.
  11. Tasker RA, Vander Velden PL, Nakatsu K. Relative cataleptic potency of narcotic analgesics, including 3,6-dibutanoylmorphine and 6-monoacetylmorphine. Prog Neuropsychopharmacol Biol Psychiatry, 1984; 8:747-50.
  12. CITAC/EURACHEM, 2002. Guide to quality in analytical chemistry: an aid to accreditation. CITAC/EURACHEM Guide, Edition: 2002.
  13. ISO/IEC 17025, General Requirements for the Competence of Testing and Calibration Laboratories. ISO, Geneva, Switzerland: 1999.
  14. Manual for use by national drug testing laboratories. Methods for impurity profiling heroin and cocaine, New York: United Nations, 2005: 13-45.