Dergiler / The European Research Journal / 2026 / Volume: 5 Issue: 5

A comparison of C-MAC videolaryngoscope and Macintosh laryngoscope in intraocular pressure changes, throat pain, intubation time and hemodynamic variables

Ceyda Özhan Çaparlar(Department of Anesthesiology and Reanimation , University of Health Sciences, Dışkapı Yıldırım Beyazıt Training and Research Hospital, Ankara, Turkey)0000-0001-5306-1956
Gözde Bumin Aydın(Department of Anesthesiology and Reanimation , University of Health Sciences, Dışkapı Yıldırım Beyazıt Training and Research Hospital, Ankara, Turkey)0000-0001-8489-8505
Evginar Sezer(Department of Anesthesiology and Reanimation , University of Health Sciences, Dışkapı Yıldırım Beyazıt Training and Research Hospital, Ankara, Turkey)0000-0002-5858-7401
Jülide Ergil(Department of Anesthesiology and Reanimation , University of Health Sciences, Dışkapı Yıldırım Beyazıt Training and Research Hospital, Ankara, Turkey)0000-0002-4580-7866
Aysun Şanal Doğan(Department of Ophthalmology, University of Health Sciences, Dışkapı Yıldırım Beyazıt Training and Research Hospital, Ankara, Turkey)0000-0002-7401-8903
Sayfa
—
Yayın Tarihi
2019-09-04
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusions: C-MAC videolaryngoscope can be recommended as the first choice in patients with high IOP requiring general anesthesia with endotracheal intubation.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objectives: The aim of the current study was to compare intraocular pressure (IOP), hemodynamic parameters and throat pain in the use of C-MAC videolaryngoscope and the Macintosh laryngoscope under general anesthesia requiring endotracheal intubation.
📊
Temel Bulgular & Veri:Methods: Seventy- eight patients aged 18-65 years, ASA ( American Society of Anesthesiologists physical status).
💡
Sonuç & Katkı:Conclusions: C-MAC videolaryngoscope can be recommended as the first choice in patients with high IOP requiring general anesthesia with endotracheal intubation.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:2000 Verileri
⚙️Değişkenler:Airway management · videolaryngoscope · intraocular pressure

Abstract

Objectives: The aim of the current study was to compare intraocular pressure (IOP), hemodynamic parameters and throat pain in the use of C-MAC videolaryngoscope and the Macintosh laryngoscope under general anesthesia requiring endotracheal intubation. Methods: Seventy- eight patients aged 18-65 years, ASA ( American Society of Anesthesiologists physical status). I-II, who underwent elective surgery under general anesthesia were scheduled in the study. The groups were allocated as Group M (Macintosh laryngoscope) and Group VL (videolaryngoscope). Standard anesthesia technique was used in both groups. To assess the depth of anesthesia which was kept between 40 and 60, a Bispectral Index Monitor Model 2000 (Aspect Medical Systems, Inc, Newton, MA) was used throughout the study. We recorded hemodynamic variables, oxygen saturation before induction, at the 3rd and at the 10th minutes after intubation. The duration of intubation was recorded as the time from the laryngoscope entering the mouth to removal with end-tidal carbon dioxide on the monitor. IOP was measured before induction, and at the 3rd and 10th minutes after intubation. Inhalation agent was given after intubation. 78 patients were included in the study. We recorded cough after extubation, and postoperative sore throat was evaluated by an anesthesiologist who was blinded to the group allocations at 10 minutes and at 24 hours postoperatively. Results: There was no significant difference between the groups regarding age (p > 0.05), mean b ody mass index (p = 0.157), mean ASA (p = 0.475), mean b ispectral index values (p = 0.084) and mean operating time (p = 0.068). The mean duration of intubation was determined to be statistically significantly longer in Group M than in Group VL (p = 0.0001). There was no statistically significant difference between the groups regarding Modified Mallampati Score (p = 0.571) and Cormack Lehane Score (p = 0.819). The mean IOP at 3rd minute after intubation was determined to be statistically significantly higher in Group M (p = 0.0001). There was no statistically significant difference between the groups in regarding cough after extubation (p = 0.549), throat pain at 10 minutes (p = 0.662) and at 24 hours postoperatively. Conclusions: C-MAC videolaryngoscope can be recommended as the first choice in patients with high IOP requiring general anesthesia with endotracheal intubation.

🔖

Bu Makaleye Atıf Yap

Çaparlar, C. Ö., Aydın, G. B., Sezer, E., Ergil, J., Doğan, A. Ş. (2019). A comparison of C-MAC videolaryngoscope and Macintosh laryngoscope in intraocular pressure changes, throat pain, intubation time and hemodynamic variables. The European Research Journal, Volume: 5 Issue: 5. https://doi.org/10.18621/eurj.419490

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Vinayagam S, Dhanger S, Tilak P, Gnanasekar R. C-MAC® video laryngoscope with D-BLADE™ and Frova introducer for awake intubation in a patient with parapharyngeal mass. Saudi J Anaesth 2016;10:471-3.
  2. Griesdale DE, Liu D, McKinney J, Choi PT. Glidescope® video-laryngoscopy versus direct laryngoscopy for endotracheal intubation: a systematic review and meta-analysis. Can J Anaesth 2012;59:41-52.
  3. Cavus E, Thee C, Moeller T, Kieckhaefer J, Doerges V, Wagner K. A randomised, controlled crossover comparison of the C-MAC videolaryngoscope with direct laryngoscopy in 150 patients during routine induction of anaesthesia. BMC Anesthesiol 2011;11:6.
  4. Das B, Samal RK, Ghosh A, Kundu R. A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery. Braz J Anesthesiol 2016;66:19-23.
  5. Ahmad N, Zahoor A, Riad W, Al Motowa S. Influence of GlideScope assisted endotracheal intubation on intraocular pressure in ophthalmic patients. Saudi J Anaesth. 2015;9:195-8.
  6. Mahjoubifar M, Boroojeny SB. Hemodynamic changes during orotracheal intubation with the Glidescope and direct laryngoscope. IRCMJ 2010;12:406-8.
  7. Win NN, Kohase H, Yoshikawa F, Wakita R, Takahashi M, Kondo N, et al. Haemodynamic changes and heart rate variability during midazolam-propofol co-induction. Anaesthesia 2007;62:561-8.
  8. Yang JC, Siu TS, Ng KF, Gong Z, Tsui SL, Wong JS. Combined effect of isoflurane and esmolol on sympathetic responses to tracheal intubation. Acta Anaesthesiol Sin 2000;38:123-30.
  9. Amini S, Shakib M. Hemodynamic changes following endotracheal intubation in patients undergoing cesarean section with general anesthesia: application of glidescope® videolaryngoscope versus direct laryngoscope. Anesth Pain Med 2015;5:e21836.
  10. Karaman T, Dogru S, Karaman S, Demir S, Kaya Z, Suren M, et al. Intraocular pressure changes: the McGrath videolaryngoscope vs the Macintosh laryngoscope: a randomized trial. J Clin Anesth 2016;34:358-64.
  11. Canbay O, Celebi N, Sahin A, Celiker V, Ozgen S, Aypar U. Ketamine gargle for attenuating postoperative sore throat. Br J Anaesth 2008;100:490-3.
  12. Cirilla DJ 2nd, Ngo J, Vaisman V, Daly C, Ata A, Sandison M, et al. Does the incidence of sore throat postoperatively increase with the use of a traditional intubation blade or the GlideScope? J Clin Anesth 2015;27:646-51.
  13. Serocki G, Neumann T, Scharf E, Dörges V, Cavus E. Indirect videolaryngoscopy with C-MAC D-Blade and GlideScope: a randomized, controlled comparison in patients with suspected difficult airways. Minerva Anestesiol 2013;79:121-9.
  14. Smereka J, Ladny JR, Naylor A, Ruetzler K, Szarpak L. C-MAC compared with direct laryngoscopy for intubation in patients with cervical spine immobilization: a manikin trial. Am J Emerg Med 2017;35:1142-6.