Dergiler / The Turkish Journal of Ear Nose and Throat / 2019 / Volume: 29 Issue: 4

Which approach is better for the protection of vestibular receptors in cochlear implant surgery: Round window or standard cochleostomy?

Muhammed Dağkıran(Department of Otorhinolaryngology, Çukurova University, Faculty of Medicine, Adana, Turkey)
Ülkü Tuncer(Department of Otorhinolaryngology, Acıbadem Adana Hospital, Adana, Turkey)
Özgür Sürmelioğlu(Department of Otorhinolaryngology, Çukurova University, Faculty of Medicine, Adana, Turkey)
Özgür Tarkan(Department of Otorhinolaryngology, Çukurova University, Faculty of Medicine, Adana, Turkey)
Süleyman Özdemir(Department of Otorhinolaryngology, Çukurova University, Faculty of Medicine, Adana, Turkey)
Elvan Onan(Department of Otorhinolaryngology, Çukurova University, Faculty of Medicine, Adana, Turkey)
Mete Kıroğlu(Department of Otorhinolaryngology, Çukurova University, Faculty of Medicine, Adana, Turkey)
Sayfa
—
Yayın Tarihi
2019-12-10
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusion: Our study results suggest that RWA for CI may minimize damage to vestibular receptor functions and vertigo symptoms than SCA.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objectives: This study aims to compare electrode insertion techniques in cochlear implantation CI as the standard cochleostomy approach SCA versus the round window approach RWA on five vestibular end-organ functions and vertigo in the pre- and postoperative period.
📊
Temel Bulgular & Veri:Patients and Methods: In total, 51 patients 22 males, 29 females; mean age 38.2 years; range 16 to 70 years with normal vestibular function and operated with single-sided CI were included in this study between January 2015 and December 2019.
💡
Sonuç & Katkı:Conclusion: Our study results suggest that RWA for CI may minimize damage to vestibular receptor functions and vertigo symptoms than SCA.
🔬Tür:Article
📍Kapsam:2015 Verileri
⚙️Değişkenler:Cervical vestibular-evoked myogenic potentials · dizziness handicap inventory · ocular vestibular-evoked myogenic potentials

Abstract

Objectives: This study aims to compare electrode insertion techniques in cochlear implantation CI as the standard cochleostomy approach SCA versus the round window approach RWA on five vestibular end-organ functions and vertigo in the pre- and postoperative period. Patients and Methods: In total, 51 patients 22 males, 29 females; mean age 38.2 years; range 16 to 70 years with normal vestibular function and operated with single-sided CI were included in this study between January 2015 and December 2019. Of the patients, 30 were operated with the RWA and 21 with the SCA. All of the patients were evaluated with the Dizziness Handicap Inventory DHI and a complete vestibular test battery including the video head impulse test vHIT , cervical vestibular-evoked myogenic potential cVEMP , and ocular vestibular-evoked myogenic potential oVEMP at one week preoperatively and one month postoperatively. Results: Patients in the RWA group had a statistically significantly better protected vestibular functions and fewer subjective vertigo symptoms in the postoperative period p<0.05 . Deterioration in at least one of the five vestibular end-organ functions was observed in eight of 21 patients 38.09% in the SCA group, compared to three of 30 10% in the RWA group. A significant correlation was detected between the vestibular tests and DHI in both groups r=0.686, p=0.001 in the SCA group and r=0.630, p<0.001 in the RWA group . Conclusion: Our study results suggest that RWA for CI may minimize damage to vestibular receptor functions and vertigo symptoms than SCA.

🔖

Bu Makaleye Atıf Yap

Dağkıran, M., Tuncer, Ü., Sürmelioğlu, Ö., Tarkan, Ö., Özdemir, S., Onan, E., Kıroğlu, M. (2019). Which approach is better for the protection of vestibular receptors in cochlear implant surgery: Round window or standard cochleostomy?. The Turkish Journal of Ear Nose and Throat, Volume: 29 Issue: 4. https://ajindex.com/articles/1329292

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (31)

  1. Fina M, Skinner M, Goebel JA, Piccirillo JF, Neely JG, Black O. Vestibular dysfunction after cochlear implantation. Otol Neurotol 2003;24:234-42.
  2. Krause E, Louza JP, Wechtenbruch J, Gürkov R. Influence of cochlear implantation on peripheral vestibular receptor function. Otolaryngol Head Neck Surg 2010;142:809-13.
  3. Batuecas-Caletrio A, Klumpp M, Santacruz-Ruiz S, Benito Gonzalez F, Gonzalez Sánchez E, Arriaga M. Vestibular function in cochlear implantation: Correlating objectiveness and subjectiveness. Laryngoscope 2015;125:2371-5.
  4. Manrique-Huarte R, Calavia D, Alvarez-Gomez L, Huarte A, Perez-Fernández N, Manrique M. Vestibulo- cochlear function after cochlear implantation in patients with Meniere’s disease. J Int Adv Otol 2018;14:18-21.
  5. Dagkiran M, Tuncer U, Surmelioglu O, Tarkan O, Ozdemir S, Cetik F, et al. How does cochlear implantation affect five vestibular end-organ functions and dizziness? Auris Nasus Larynx 2019;46:178-85.
  6. Hänsel T, Gauger U, Bernhard N, Behzadi N, Romo Ventura ME, Hofmann V, et al. Meta-analysis of subjective complaints of vertigo and vestibular tests after cochlear implantation. Laryngoscope 2018;128:2110-23.
  7. Enticott JC, Tari S, Koh SM, Dowell RC, O’Leary SJ. Cochlear implant and vestibular function. Otol Neurotol 2006;27:824-30.
  8. Schwab B, Durisin M, Kontorinis G. Investigation of balance function using dynamic posturography under electrical-acoustic stimulation in cochlear implant recipients. Int J Otolaryngol 2010;2010:978594.
  9. Devroede B, Pauwels I, Le Bon SD, Monstrey J, Mansbach AL. Interest of vestibular evaluation in sequentially implanted children: Preliminary results. Eur Ann Otorhinolaryngol Head Neck Dis 2016;133:S7-S11.
  10. Kubo T, Yamamoto K, Iwaki T, Doi K, Tamura M. Different forms of dizziness occurring after cochlear implant. Eur Arch Otorhinolaryngol 2001;258:9-12.
  11. Melvin TA, Della Santina CC, Carey JP, Migliaccio AA. The effects of cochlear implantation on vestibular function. Otol Neurotol 2009;30:87-94.
  12. Krause E, Louza JP, Hempel JM, Wechtenbruch J, Rader T, Gürkov R. Effect of cochlear implantation on horizontal semicircular canal function. Eur Arch Otorhinolaryngol 2009;266:811-7.
  13. O’Leary MJ, Fayad J, House WF, Linthicum FH Jr. Electrode insertion trauma in cochlear implantation. Ann Otol Rhinol Laryngol 1991;100:695-9.
  14. van den Broek P, Huygen PL, Mens LH, Admiraal RJ, Spies T. Vestibular function in cochlear implant patients. Acta Otolaryngol 1993;113:263-5.
  15. Cohen NL, Hoffman RA. Complications of cochlear implant surgery in adults and children. Ann Otol Rhinol Laryngol 1991;100:708-11.
  16. Tien HC, Linthicum FH Jr. Histopathologic changes in the vestibule after cochlear implantation. Otolaryngol Head Neck Surg 2002;127:260-4.
  17. House WF. Surgical considerations in cochlear implantation. Ann Otol Rhinol Laryngol Suppl 1982;91:15-20.
  18. Skarzynski H, Lorens A, Zgoda M, Piotrowska A, Skarzynski PH, Szkielkowska A. Atraumatic round window deep insertion of cochlear electrodes. Acta Otolaryngol 2011;131:740-9.
  19. Adunka O, Unkelbach MH, Mack M, Hambek M, Gstoettner W, Kiefer J. Cochlear implantation via the round window membrane minimizes trauma to cochlear structures: a histologically controlled insertion study. Acta Otolaryngol 2004;124:807-12.
  20. Burghard A, Lenarz T, Kral A, Paasche G. Insertion site and sealing technique affect residual hearing and tissue formation after cochlear implantation. Hear Res 2014;312:21-7.
  21. Todt I, Basta D, Ernst A. Does the surgical approach in cochlear implantation influence the occurrence of postoperative vertigo? Otolaryngol Head Neck Surg 2008;138:8-12.
  22. Kluenter HD, Lang-Roth R, Beutner D, Hüttenbrink KB, Guntinas-Lichius O. Postural control before and after cochlear implantation: standard cochleostomy versus round window approach. Acta Otolaryngol 2010;130:696-701.
  23. Nordfalk KF, Rasmussen K, Bunne M, Jablonski GE. Deep round window insertion versus standard approach in cochlear implant surgery. Eur Arch Otorhinolaryngol 2016;273:43-50.
  24. Korsager LEH, Schmidt JH, Faber C, Wanscher JH. Vestibular outcome after cochlear implantation is not related to surgical technique: a double blinded, randomized clinical trial of round window approach versus cochleostomy. Otol Neurotol 2018;39:306-12.
  25. Karapolat H, Eyigor S, Kirazli Y, Celebisoy N, Bilgen C, Kirazli T. Reliability, validity, and sensitivity to change of Turkish Activities-specific Balance Confidence Scale in patients with unilateral peripheral vestibular disease. Int J Rehabil Res 2010;33:12-8.
  26. Jacobson GP, Newman CW. The development of the Dizziness Handicap Inventory. Arch Otolaryngol Head Neck Surg 1990;116:424-7.
  27. Jacobson GP, Newman CW, Hunter L, Balzer GK. Balance function test correlates of the Dizziness Handicap Inventory. J Am Acad Audiol 1991;2:253-60.
  28. O’Connell BP, Cakir A, Hunter JB, Francis DO, Noble JH, Labadie RF, et al. Electrode Location and Angular Insertion Depth Are Predictors of Audiologic Outcomes in Cochlear Implantation. Otol Neurotol 2016;37:1016-23.
  29. Bonucci AS, Costa Filho OA, Mariotto LD, Amantini RC, Alvarenga Kde F. Vestibular function in cochlear implant users. Braz J Otorhinolaryngol 2008;74:273-8.
  30. Basta D, Todt I, Goepel F, Ernst A. Loss of saccular function after cochlear implantation: the diagnostic impact of intracochlear electrically elicited vestibular evoked myogenic potentials. Audiol Neurootol 2008;13:187-92.
  31. Brey RH, Facer GW, Trine MB, Lynn SG, Peterson AM, Suman VJ. Vestibular effects associated with implantation of a multiple channel cochlear prosthesis. Am J Otol 1995;16:424-30.