Dergiler / Harran Üniversitesi Tıp Fakültesi Dergisi / 2026 / Cilt: 23 Sayı: 3

Ortotopik Karaciğer Naklinde PiCCO2 Tabanlı Hedefe Yönelik Sıvı Yönetiminde Femoral ve Radial Arter Monitörizasyonunun Karşılaştırılması:Prospektif Gözlemsel Çalışma

Comparison of Femoral and Radial Arterial Monitoring for PICCO2-Guided Goal-Directed Fluid Management in Orthotopic Liver Transplantation: A Prospective Observational Study

Hacer Gülerce Uçar(ISPARTA ŞEHİR HASTANESİ)0009-0007-1203-483X
Hüseyin İlksen Toprak(İSTANBUL AYDIN ÜNİVERSİTESİ)0000-0001-9293-8116
Sayfa
450–458
Yayın Tarihi
2026-09-21
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Bulgular: Gruplar demografik özellikler, cerrahi süre, sıvı ve kan ürünleri, vazopresör gereksinimi, kreatinin seyri ve yoğun bakımda kalış süresi açısından benzer bulunmuştur.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Amaç: Ortotopik karaciğer nakli, derin vazodilatasyon, masif kan kaybı, büyük damar klempleri ve reperfüzyon sendromu nedeniyle intraoperatif dönemde en ağır hemodinamik dalgalanmaların izlendiği cerrahi girişimlerden biridir ve bu hastalarda invaziv arteriyel monitörizasyondan elde edilen basınç değerlerinin gerçek santral dolaşımı ne ölçüde yansıttığı, sıvı ve vazopresör tedavisinin titrasyonu açısından kritik önem taşımaktadır.
📊
Temel Bulgular & Veri:Bu çalışmanın amacı, canlı vericili ortotopik karaciğer nakli uygulanan erişkin alıcılarda radial ve femoral arterden elde edilen PiCCO2® tabanlı hedefe yönelik sıvı yönetimini karşılaştırmak ve monitörizasyon yerinin hemodinamik parametreler, renal fonksiyon ve kısa dönem sonuçlar üzerine etkisini değerlendirmektir.
💡
Sonuç & Katkı:Bulgular: Gruplar demografik özellikler, cerrahi süre, sıvı ve kan ürünleri, vazopresör gereksinimi, kreatinin seyri ve yoğun bakımda kalış süresi açısından benzer bulunmuştur.
🔬Tür:Laboratuvar & Saha Deneyi
📍Kapsam:36 hasta
⚙️Değişkenler:Transplantasyon · hemodinami · PiCCO2

Özet

Amaç: Ortotopik karaciğer nakli, derin vazodilatasyon, masif kan kaybı, büyük damar klempleri ve reperfüzyon sendromu nedeniyle intraoperatif dönemde en ağır hemodinamik dalgalanmaların izlendiği cerrahi girişimlerden biridir ve bu hastalarda invaziv arteriyel monitörizasyondan elde edilen basınç değerlerinin gerçek santral dolaşımı ne ölçüde yansıttığı, sıvı ve vazopresör tedavisinin titrasyonu açısından kritik önem taşımaktadır. Bu çalışmanın amacı, canlı vericili ortotopik karaciğer nakli uygulanan erişkin alıcılarda radial ve femoral arterden elde edilen PiCCO2® tabanlı hedefe yönelik sıvı yönetimini karşılaştırmak ve monitörizasyon yerinin hemodinamik parametreler, renal fonksiyon ve kısa dönem sonuçlar üzerine etkisini değerlendirmektir. Materyal ve metod: Bu prospektif gözlemsel çalışmada, canlı vericili karaciğer nakli planlanan 18-65 yaş aralığında 36 hasta izlenmiş ve rastgele radial (n=18) veya femoral (n=18) arter grubuna atanmıştır. Tüm hastalarda PiCCO2® monitörizasyon sistemi ile altı zaman noktasında sistolik ve ortalama arter basıncı, kardiyak indeks, SVV, PPV ve ELWI değerleri kaydedilmiş;MAP ≥65 mmHg olacak şekilde SVV >10 olduğunda sıvı, SVV ≤10 olduğunda norepinefrin temelli vazokonstriktör tedavi uygulanmıştır. Bulgular: Gruplar demografik özellikler, cerrahi süre, sıvı ve kan ürünleri, vazopresör gereksinimi, kreatinin seyri ve yoğun bakımda kalış süresi açısından benzer bulunmuştur. Femoral grupta anhepatik başlangıç ve klempleme döneminde sistolik basınçlar daha yüksek saptanırken, ortalama arter basıncı, kardiyak indeks, SVV/PPV ve ELWI değerleri ile postoperatif böbrek fonksiyonu ve mortalite oranları açısından anlamlı fark izlenmemiştir. Sonuç: Bulgularımız, PiCCO2® eşliğinde protokollü hedefe yönelik tedavi altında radial ve femoral arter monitörizasyonunun klinik sonuçlar bakımından benzer olduğunu, ancak femoral basınç izleminin en kritik fazlarda daha yüksek sistolik değerler sağlayarak özellikle uç organ perfüzyonunun korunmasında potansiyel avantaj sunabileceğini düşündürmektedir.

Abstract

Background: Orthotopic liver transplantation (OLT) is characterized by profound intraoperative hemodynamic instability due to severe vasodilation, massive blood loss, major vascular clamping, and reperfusion syndrome. In this context, the extent to which invasive arterial pressure monitoring reflects true central hemodynamics is crucial for accurate titration of fluid and vasoactive therapy. This study aimed to compare PICCO2®-guided goal-directed fluid management via radial versus femoral arterial access in adult recipients undergoing living-donor OLT and to evaluate the impact of monitoring site on hemodynamic parameters, renal function, and short-term clinical outcomes. Materials and Methods: In this prospective observational study, 36 adult OLT recipients (18-65 years) were randomized to radial (n=18) or femoral (n=18) arterial monitoring. PICCO2® measurements-including systolic and mean arterial pressure, cardiac index, stroke volume variation (SVV), pulse pressure variation (PPV), and extravascular lung water index (ELWI)- were recorded at six intraoperative time points. Goal-directed therapy targeted MAP ≥65 mmHg; patients with SVV >10% received fluid boluses, whereas those with SVV ≤10% received norepinephrine-based vasoconstrictor therapy. Results: Groups were comparable in demographics, surgical duration, fluid and blood product administration, vasopressor requirements, creatinine trends, and ICU stay. Femoral monitoring yielded higher systolic pressures during early anhepatic and clamping phases, whereas MAP, cardiac index, SVV/PPV, ELWI, postoperative renal function, and mortality rates showed no significant intergroup differences. Conclusions: Findings suggest that radial and femoral arterial monitoring provide similar clinical outcomes during PICCO2®-guided goal-directed therapy in OLT. However, the higher systolic pressures observed with femoral monitoring during critical phases may offer a physiological advantage by supporting end-organ perfusion.

🔖

Bu Makaleye Atıf Yap

Uçar, H. G., Toprak, H. İ. (2026). Ortotopik Karaciğer Naklinde PiCCO2 Tabanlı Hedefe Yönelik Sıvı Yönetiminde Femoral ve Radial Arter Monitörizasyonunun Karşılaştırılması:Prospektif Gözlemsel Çalışma. Harran Üniversitesi Tıp Fakültesi Dergisi, Cilt: 23 Sayı: 3, 450–458. https://ajindex.com/articles/1080786

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (15)

  1. Huygh J, Peeters Y, Bernards J, Malbrain ML. Hemodynamic monitoring in the critically ill:an overview of current cardiac output monitoring methods. F1000Res. 2016;5:F1000
  2. Broch O, Bein B, Gruenewald M, Höcker J, Schöttler J, Meybohm P, et al. Accuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion index. Acta Anaesthesiol Scand. 2011;55:686-93.
  3. Greer MR, Carney S, McPheeters RA, Aguiniga P, Rubio S, Lee J. Radial Arterial Lines Have a Higher Failure Rate than Femoral. West J Emerg Med. 2018;19(2):364-71.
  4. Arnal D, Garutti I, Perez-Peña J, Olmedilla L, Tzenkov IG. Radial to femoral arterial blood pressure differences during liver transplantation. Anaesthesia. 2005;60:766-71.
  5. Galluccio ST, Chapman MJ, Finnis ME. Femoral-radial arterial pressure gradients in critically ill patients. Crit Care Resusc. 2009;11:34-8.
  6. Chung RT, Poolside DK. Cirrhosis and its complications. In:Kasper DL, Braunwald E, Fauci AS, et al, editors. Harrison’s principles of internal medicine. 16th ed. McGraw-Hill, 2005:1863-9.
  7. Lee M, Weinberg L, Pearce B, Scurrah N, Story DA, Pillai P, et al. Agreement between radial and femoral arterial blood pressure measurements during orthotopic liver transplantation. Crit Care Resusc. 2015;17(2):101-7.
  8. Della Rocca G, Brondani A, Costa MG. Intraoperative hemodynamic monitoring during organ transplantation:what is new? Curr Opin Organ Transplant. 2009;14:2916
  9. Rocca DG, Costa MG, Pompei L, Coccia C, Pietropaoli P. Continuous and intermittent cardiac output measurement:pulmonary artery catheter versus aortic transpulmonary technique. British Journal of Anaesthesia. 2002;88:350-6
  10. Shin BS, Kim GS, Ko JS, Gwak MS, Yang M, Kim CS, et al. Comparison of Femoral Arterial Blood Pressure With Radial Arterial Blood Pressure and Noninvasive Upper Arm Blood Pressure in the Reperfusion Period During Liver Transplantation. Transplantation Proceedings. 2007;39:1326-8.
  11. Chauhan S, Saxena N, Mehrotra S, Rao BH, Sahu M,Sahu M, et al. Femoral Artery Pressures Are More Reliable Than Radial Artery Pressures on Initiation of Cardiopulmonary Bypass. Journal of Cardiothoracic and Vascular Anesthesia. 2000:14;274-6.
  12. Reydellet L, Blasco V, Mercier MF, Antonini F, Nafati C, Harti-Souab K, et al. Impact of a goal-directed therapy protocol on postoperative fluid balance in patients undergoing liver transplantation. Anaesthesia Critical Care &Pain Medicine. 2014;33:47-54.
  13. Li-ping Z, Min L, Lu Y. Effects of different vasopressors on hemodynamics in patients undergoing orthotopic liver transplantation. Chin Med J. 2005;118;1952-8.
  14. Iwata H. Importance of intraoperative fluid management. J Thorac Dis 2019;11(Suppl 15):S2002-4.
  15. Goepfert MS, Richter HS, Eulenburg Cz, Gruetzmacher j, Rafflenbeul E, Roeher K, et al. Individually Optimized Hemodynamic Therapy Reduces Complications and Length of Stay in theIntensive Care Unit. Anesthesiology. 2013;119:824-36.