Dergiler / Medicine Science / 2015 / Cilt: 4 Sayı: 3

Useage of Intra-aortic Baloon Pump in the Open Heart Surgeries [Açık Kalp Ameliyatlarında İntra-Aortik Balon Pompası Kullanılması]

Sayfa
2593–2609
Yayın Tarihi
2015-12-22
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Keywords: Open-heart surgery, Intra-aortic balloon pump, transesophageal echocardiography

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:AbstractIn recent years, by means of advances in cardiology and cardiovascular surgery, morbidity and mortality rates related to cardiac disease are declining.
📊
Temel Bulgular & Veri:IABP which is used particularly in the treatment of low cardiac output syndrome has found area of application widely in a short time, and still is the most widely used device among the ventricular assist devices in the world.
💡
Sonuç & Katkı:Keywords: Open-heart surgery, Intra-aortic balloon pump, transesophageal echocardiography
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Açık kalp ameliyatı · intraaortik balon pompası · transözofagal

Özet

AbstractIn recent years, by means of advances in cardiology and cardiovascular surgery, morbidity and mortality rates related to cardiac disease are declining. IABP which is used particularly in the treatment of low cardiac output syndrome has found area of application widely in a short time, and still is the most widely used device among the ventricular assist devices in the world. Keywords: Open-heart surgery, Intra-aortic balloon pump, transesophageal echocardiography

🔖

Bu Makaleye Atıf Yap

OZDEMİR, O. G., YENER, A. U., SACAR, M. (2015). Useage of Intra-aortic Baloon Pump in the Open Heart Surgeries [Açık Kalp Ameliyatlarında İntra-Aortik Balon Pompası Kullanılması]. Medicine Science, Cilt: 4 Sayı: 3, 2593–2609. https://ajindex.com/articles/1003239

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (11)

  1. Kaynaklar Küçükaksu DS, Şener E, Taşdemir O. Kalp Transplantasyonuna Mekanik Sistemlerle Köprüleme; Hasta ve Cihaz Seçimi. Turk Gogus Kalp Dama. 2002;10(3):190-200. Gibbon JH. Application of a mechanical heart and lung apparatus to cardiac surgery. Minn Med. 1954;37(3):171. Yalınız H, Ulus T. İntraaortik Balon. In: Paç M, ed, Kalp ve Damar Cerrahisi. Ankara: Akademisyen Kitapevi, 2013. Harken DE. Presented at the intenational Colloge of Cardiology Meeting. Brussels, Belgium 1958.
  2. Clauss RH, Birtwell WC, Albertal G. Assisted circulation, I: the arteriyel counterpulsator. J Thorac Cardiovas Surg. 1961;41:447. Moulopoulos SD, Topaz S, Kolff WJ. Diastolic balloon pumping (with carbon dioxide) in the aorta-a mechanical assistance to the failing circulation. Am Heart J. 1962;63:669. DeBakey ME. Left ventricular bypass pump for cardiac assistance. Clinical experience. Am J Cardiol. 1971;27(1):3-6.
  3. Kontrowitz A, Tjonneland S, Freed PS. Initial clinical experience with intraaortic baloon pumping in cardiogenic shock. JAMA. 1968;203(2):135-7. Kuralay E. İntraaortik Balon Desteği. In:Demirkılıç U, ed, Ekstrakorporal Dolaşım. Ankara: Eflatun Yayınevi, 2008;475-518.
  4. Kogan A, Preisman S, Sternik L, Orlov B, Spiegelstein D, Hod H, Malachy A, Levin S, Raanani E. Heparin-free management of intraaortic balloon pump after cardiac surgery. J Card Surg. 2012;27(4):434-7.
  5. Yener AÜ, Coşkun Ö, Öztopuz RÖ Mekanik Dolaşım Desteği. In: Saçar M, ed, Kardiyopulmoner Baypas. Ankara: Pozitif Matbaa, 2014;125-143.
  6. Buchanan SA, Langerburg SE, Mauney MC. Ambulatory intraaortik balloon counterpulsation. Ann Thorac Surg. 1994;58:1547-9.
  7. Zeybek R, İşkesen İ. İntraaortik Balon Pompası. Klinik Perfüzyon El Kitabı. Manisa.1999:155-166.
  8. Taşoğlu İ, İmren Y, Gökgöz L. Ameliyat sırasında İntra-oortik balon pompası takılmasında transözofageal ekokardiyografinin önemi. Turk Gogus Kalp Dama. 2007;15(3):212-6.
  9. Patel MR, Smalling RW, Thiele H, Barnhart HX, Zhou Y, Chandra P, Chew D, Cohen M, French J, Perera D, Ohman EM. Intra-aortic balloon counterpulsation and infarct size in patients with acute anterior myocardial infarction without shock: the CRISP AMI randomized trial. JAMA. 2011;306(12):1329-37.
  10. Gür AK, Eker E, Akyol A, Akdağ S, Kolcu Z, Odabaşı D, Uçar H. Kliniğimizde Açık kalp operasyonlarındaki intraaortik balon pompası kullanımı. Harran Üniversitesi Tıp Fakültesi Dergisi. 2014;11(1):10-14.
  11. Jan T, Christenson MD, François Simonet MD, Martin Schmuziger MD. Economic ımpact of preoperative ıntraaor