Journals / European Journal of General Medicine / 2012 / Cilt: 9 Sayı: 1

Evaluation of atherosclerotic polaque, coronary stent and coronary by-pass grafts with 128-slice CT and technical optimization: our single center experiences

Pages
14–21
Publication Date
2012-03-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗

Özet

-

🔖

Cite This Article

KAYAN, M., ÇETİN, M., TÜRKER, Y., YILMAZ, Ö., MUNDUZ, M., YAŞAR, S., DUYMUŞ, M. (2012). Evaluation of atherosclerotic polaque, coronary stent and coronary by-pass grafts with 128-slice CT and technical optimization: our single center experiences. European Journal of General Medicine, Cilt: 9 Sayı: 1, 14–21. https://ajindex.com/articles/987680

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Mintz GS, Nissen SE, Anderson WD, et al. A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents. J Am Coll Cardiol 2001;37(5):1478-92.
  2. Agatston AS, Janowitz WR, Hildner FJ, Zusmer NR, Viamonte M, Jr, Detrano R. Quantification of coronary ar- tery calcium using ultrafast computed tomography. J Am Coll Cardiol 1990;15(4):827-32.
  3. Mautner GC, Mautner SL, Froehlich J, et al. Coronary artery calcification: assessment with electron beam CT and histomorphometric correlation. Radiology 1994;192(3):619-23.
  4. Austen WG, Edwards JE, Frye RL, et al. A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 1975;51(4 Suppl):5-40.
  5. Kuettner A, Beck T, Drosch T, et al. Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal reso- lution. J Am Coll Cardiol 2005;45(1):123-7.
  6. Cademartiri F, Mollet NR, Lemos PA, et al. Impact of coronary calcium score on diagnostic accuracy for the detection of significant coronary stenosis with mul- tislice computed tomography angiography. Am J Cardiol 2005;95(10):1225-7.
  7. Leiner T, Gerretsen S, Botnar R, et al. Magnetic resonance imaging of atherosclerosis. Eur Radiol 2005;15(6):1087-99.
  8. Windecker S, Maier-Rudolph W, Bonzel T, et al. Interventional cardiology in Europe 1995. Working Group Coronary Circulation of the European Society of Cardiology. Eur Heart J 1999;20(7):484-95.
  9. Papaconstantinou HD, Marshall AJ, Burrell CJ. Diagnostic cardiac catheterisation in a hospital without on-site car- diac surgery. Heart 1999;81(5):465-9.
  10. Hu H, He HD, Foley WD, Fox SH. Four multidetector-row helical CT: image quality and volume coverage speed. Radiology 2000;215(1):55-62.
  11. Mahesh M, Cody DD. Physics of cardiac imaging with multi- ple-row detector CT. Radiographics 2007;27(5):1495-509.
  12. Pannu HK, Jacobs JE, Lai S, Fishman EK. Coronary CT an- giography with 64-MDCT: assessment of vessel visibility. AJR Am J Roentgenol 2006;187(1):119-26.
  13. Takeyama N, Ohgiya Y, Itokawa H, et al. Comparison of 40 and 60 milliliters of contrast in assessment of the carotid artery by computed tomography angiography. Acta Radiol 2008;49(9):1068-78.
  14. Sangiorgi G, Rumberger JA, Severson A, et al. Arterial cal- cification and not lumen stenosis is highly correlated with atherosclerotic plaque burden in humans: a histologi